UIDN User IDeNtification Class Description Command syntax System parameter settings Sets up the text string that is placed in the upper portions of the SMPTE133 and Cubes images. The command can be used to add a company name or other identification to the images. The command will not change the text in a currently displayed image; it must be redrawn to use the new text. The factory default string is “Quantum Data.” The UIDN? query returns the current text string. UIDN string string text string 80 characters in length Query syntax Query response Other required commands Example UIDN? string The IMGU command redraws the last selected test image. The ALLU command updates hardware to the new setting and redraws the test image. UIDN "XYZ Monitor Mfg." IMGL SMPTE133 IMGU Video Test Generator User Guide // Change text string // Select image that uses the text string // Draw the image using new string 553