Download Sharp 37DM-23H Specifications
Transcript
CA1 Course Notes CA1 Non Volatile Memory Codes All user setting are contained within the non volatile memory, IC1002 including a number of pre-set receiver parameters. Although these are pre-set for the model, they can be changed. Under normal circumstances this would serve no purpose, as the circuitry to preform the various functions may not be fitted. However, should a data corruption occur, or there is a need to modify the software, the locations and functions are shown below. At the end of this section an explanation is given on how to set these codes. CA1 NVM Locations and Functions Address ( HEX ) Description 00 Red Colour Temperature 01 Green Colour Temperature 02 Blue Colour Temperature 03 Vertical Shift 04 Horizontal Shift 05 Vertical Amplitude 06 Vertical Slope 07 Luminance Delay - PAL 08 Luminance Delay - SECAM 09 S-Correction 0A Automatic Gain Control 0B Bit 0 : Bit 1 : 0 = No Front AV Sockets Fitted, 1 = Front AV Socket Fitted Bit 2 : 0 = Tuning Unlocked, 1= Tuning Locked ( Hotel Mode ) Bit 3 : 0 = All Band Tuning, 1= UHF Band Tuning Only Bit 4 : 0 = PAL System Only, 1 = PAL and SECAM Systems Bit 5 : 0 = Child Lock Disabled, 1 = Child Lock Activated Bit 6 : 0 = Manual Tuning, 1 = Automatic Tuning Bit 7 : 0 = OSD Symbols, 1 = OSD in English 0C AFT Adjustment Value for B/G and L Systems 0D AFT Adjustment Value for L’ System 0E Maximum Volume Limit 0F Firm 10 Red Colour Temperature 11 Green Colour Temperature 12 Blue Colour Temperature 13 Vertical Shift 14 Horizontal Shift 15 Vertical Amplitude 16 Vertical Slope Page 64 Sharp Electronics (UK) Limited CE Technical Support Group Default Value