Download Quatech DS-200 Specifications
Transcript
Tritech International Ltd SeaKing System Options OM 5. Alternate 2 String Format This output provides a string format that is compatible with the Ulvertech data format but with an extra depth digit to allow readings greater than 999.99metres. The following serial data formats are configurable on the UK94 surface unit: b) 9600 baud, 8 data bits, 2 stop bit, no parity. [These may need to be configured on the SCU to replicate a UK94 output if the receiving terminal expects this data format] Alternate 2 - Reply Data Structure Data Description Depth in centimetres (includes entered vertical or zero offsets) Comma character Altitude in centimetres (includes entered vertical offset) Terminator (Carriage Return + Line Feed) Example: Depth Altimeter reading = 87.92 metres = 24.75 metres Data Range 0 to 400000 Field Range dddddd N/A 0 to 9999 N/A , aaaa <CR><LF> = 008792 = 2475 ASCII Output Always = “008792,2475<CR><LF>” Where; “,” is a comma (ASCII code 44), “<CR>” is Carriage Return (ASCII code 13), “<LF>” is Line Feed (ASCII code 10). Issue 3 TIL – Eng – Spec – 040 Page 27 of 44