Download RAD Data comm E1 Interface Converter RIC-E1 Specifications

Transcript
RIC-E1 Installation and Operation Manual
Appendix D IR-IP Interface Module
Table D-3. IR-IP Controls
Control
RIC-E1
Function
Values
Enables IR-IP to learn its IP
ON – IP address learning is enabled
Default
Setting
RIC-E1/R
DIP switch, IP LEARN pushbutton,
section 1
DIP switch, section 5
OFF – IP address learning is disabled OFF
Note: IP LEARN pushbutton settings override settings of the DIP switch.
DIP switch, DIP switch, section 4
section 2
Selects the WAN protocol
DIP switch, DIP switch, section 3
section 3
Selects the LAN mode
DIP switch, DIP switch, section 2
section 4
ON – The test loopback is activated
Controls the remote WAN test
loopback, which returns packets
OFF – The test loopback is disabled
received from the WAN back toward
the WAN
–
DIP switch, section 6
ON – Forces default IP password
Allows the user to operate the
and/or no password protection
module in case the IP address and/or
Telnet password are lost
OFF
OFF – IR-IP operates according to
user configuration
–
DIP switch, section 1
Not in use
Note
ON – PPP protocol
OFF – Frame Relay protocol
OFF
ON – Full duplex operation
OFF
OFF – Half duplex operation
OFF
–
–
When using the IP LEARN pushbutton for the IP address configuration, make sure
that the PNL SW jumper (JP5) on the RIC-E1/R PCB is set to EN.
Table D-4 provides the pinout of the IR-IP RJ-45 connector.
Table D-4. RJ-45 Pinout
Pin
Name
Function
1
TD (+)
Transmit data positive
2
TD (-)
Transmit data negative
3
RD (+)
Receive data positive
6
RD (-)
Receive data negative
D.4 IR-IP Management Subsystem, General
The IR-IP interface module management subsystem supports the following
functions:
• Preliminary configuration
•
Configuration of management access parameters
•
Advanced configuration of IR-IP parameters
•
Collection and display of statistical performance data
•
Maintenance functions, which include:
Software downloading
IR-IP Management Subsystem, General
D-5