Return To Table Of Contents SECTION II TESTING AND TROUBLESHOOTING Table 2-1. Troubleshooting Guide - continued Problem Symptom Check Correction Control PC board has had a software / hardware failure. DIsconnect power; then check for disconnected wiring in sterilizer or facility. Connect power & run additional cycle. If error code persists, replace control PC board. Refer to para 4.13. Sterilizer does not complete (Software interrupt error) cycle. Control PC board has a software / hardware malfunction. Disconnect power for approx. 10 seconds; then connect power & run additional cycle. If error code persists, replace control PC board. Refer to para 4.13. Sterilizer does not complete cycle. Control PC board has a software / hardware malfunction. Disconnect power for approx. 10 seconds; then connect power & run additional cycle. If error code persists, replace control PC board. Refer to para 4.13. Sterilizer does not complete cycle. Door switch is malfunctioning. Perform continuity check on door switch. Replace door switch. Refer to para 4.14. Unplug pulse solenoid; then run M9/M11 Door Opening Test. Refer to para 4.28. Replace pulse solenoid. Refer to para 4.15. Error code 10 (Watchdog timer reset error) Sterilizer does not complete cycle. Probable Cause Error code 11 Error code 12 (Ram test error) Error code 13 -M9D & M11D only (Door switch status unchanged since last cycle) Blown Fuses Main fuse on PC board blown Shor t in pulse solenoid. No Display Lights Unit displays temp. & pressure, but does not show LED status lights. Low Water Light (comes on after Water continuously fills chamber. - Water level sensor dir ty or malfunctioning. Clean water level sensor; then perform continuity check. Replace water level sensor. Refer to para 4.10. Temperature sensor malfunctioning. Disconnect temp. sensor from PC board; then check for proper operation. Replace temperature sensor. Refer to para 4.9. Filter is dir ty/clogged. Clean filter with speedclean & brush or in ultrasonic cleaner. Replace filter if necessary. Refer to para 4.19. Debris trapped in fill solenoid. Disassemble fill solenoid and remove any debris. Replace fill solenoid. Refer to para 4.12. approx. 5 min.) Water is not entering chamber. Low Water Light (comes on Low water light illuminates as Condensing tank level soon as cycle is star ted. sensor malfunctioning. immediately) (Older-style units only) © Midmark Corporation 2002 SF-1827 - Disconnect power for approx. 30 seconds. Then connect power and check for proper operation. Page 2-4 - Unplug sensor from PC board & permanantely jumper connection on board. Printed in U.S.A.