Download Compaq HSG80 - StorageWorks RAID Array Controller Specifications
Transcript
Event Reporting: Templates and Codes 5–43 Table 5–15 Instance Codes (Sheet 22 of 24) Description Template Repair Action Code 0E098901 The remote copy set specified by the Remote Copy Set Name field has gone inoperative due to a disaster tolerance failsafe locked condition. 90 89 0E0A8D01 The unit is not made available to the host for the remote copy set specified in the Remote Copy Set Name field. This controller cannot verify a site failover did not occur; hence, it is not safe to present the WWLID. 90 8D 0E0B8E01 The unit is not made available to the host for the remote copy set specified in the Remote Copy Set Name field. This controller discovered a site failover occurred; hence, it cannot present the WWLID. 90 8E 0E0C8C01 The copy was terminated due to a read failure on the initiator unit. The initiator unit is specified by the Initiator WWLID field. 90 8C 0E0E8B01 Applies to write failure on the target unit. 0E0F8B01 The copy was terminated due to a write failure on the target unit. The write failure was due to the links being down (target inaccessible). The copy will restart when at least one link is restored. The initiator unit is specified by the Initiator WWLID field. 90 8B 0E100064 A link (connection) to a target controller was just restored. 90 00 0E110064 The logical unit specified by the Target WWLID has transitioned from the merging state to the normal state. 90 00 0E120064 A link (connection) to a target controller was just restored. 90 00 0E1A8B01 Write history log merge has encountered a write error on the remote target unit. 90 8B 0E1D8B01 Write history log merge detected the target unit has failed. 90 8B 0E1E8C01 The asynchronous merge was terminated due to a read failure on the initiator unit. 90 8C 0E1F8B01 The asynchronous merge was terminated due to a write failure on the target unit. 90 8B 0E210064 The logical unit specified by the Target WWLID field has transitioned from the normal state to the write history logging state due to a remote connection event (the target controllers are no longer accessible) or CLI SUSPEND command. 90 00 0E220064 The logical unit specified by the Target WWLID field has transitioned from the logging state to the merging state due to a remote connection event (the target controllers are no longer accessible) or CLI RESUME command. 90 00 Instance Code 8B