Event Reporting: Templates and Codes
5–43
Table 5–15 Instance Codes (Sheet 22 of 24)
Description
Template
Repair
Action
Code
0E098901
The remote copy set specified by the Remote Copy Set Name field has gone
inoperative due to a disaster tolerance failsafe locked condition.
90
89
0E0A8D01
The unit is not made available to the host for the remote copy set specified in
the Remote Copy Set Name field. This controller cannot verify a site failover
did not occur; hence, it is not safe to present the WWLID.
90
8D
0E0B8E01
The unit is not made available to the host for the remote copy set specified in
the Remote Copy Set Name field. This controller discovered a site failover
occurred; hence, it cannot present the WWLID.
90
8E
0E0C8C01
The copy was terminated due to a read failure on the initiator unit. The
initiator unit is specified by the Initiator WWLID field.
90
8C
0E0E8B01
Applies to write failure on the target unit.
0E0F8B01
The copy was terminated due to a write failure on the target unit. The write
failure was due to the links being down (target inaccessible). The copy will
restart when at least one link is restored. The initiator unit is specified by the
Initiator WWLID field.
90
8B
0E100064
A link (connection) to a target controller was just restored.
90
00
0E110064
The logical unit specified by the Target WWLID has transitioned from the
merging state to the normal state.
90
00
0E120064
A link (connection) to a target controller was just restored.
90
00
0E1A8B01
Write history log merge has encountered a write error on the remote target
unit.
90
8B
0E1D8B01
Write history log merge detected the target unit has failed.
90
8B
0E1E8C01
The asynchronous merge was terminated due to a read failure on the
initiator unit.
90
8C
0E1F8B01
The asynchronous merge was terminated due to a write failure on the target
unit.
90
8B
0E210064
The logical unit specified by the Target WWLID field has transitioned from the
normal state to the write history logging state due to a remote connection
event (the target controllers are no longer accessible) or CLI SUSPEND
command.
90
00
0E220064
The logical unit specified by the Target WWLID field has transitioned from the
logging state to the merging state due to a remote connection event (the
target controllers are no longer accessible) or CLI RESUME command.
90
00
Instance
Code
8B