Download Sigma S2Ba Operating instructions
Transcript
Installation, hydraulic CAUTION! Danger of the integral relief valve failing The integral relief valve no longer operates reliably with feed chemicals having a viscosity of greater than 200 mPa s. – Only use the integral relief valve with feed chemicals having a viscosity up to 200 mPa s. CAUTION! Warning against leaks Feed chemical which remains in the overflow line at the relief valve, can attack the valve or cause it to leak – Route the overflow line with a continuous slope and moreover with the tube nozzle pointed downwards - see Fig. 16. If the overflow line is fed into the suction line, the bleed func‐ tion is blocked. P_SI_0023 Fig. 16: Permissible alignment of the relief valve Therefore lead the overflow line back into the storage tank. When operating the integral relief valve close to the opening pressure, a minimal overflow into the overflow line can occur. Diaphragm rupture sensor CAUTION! Danger resulting from unnoticed diaphragm rupture If the pump has been ordered with an electric diaphragm rup‐ ture sensor, it still has to be installed. – Screw the enclosed diaphragm rupture sensor into the liquid end. CAUTION! Warning of unnoticed diaphragm rupture Only above approximately 2 bar system back pressure is a signal generated upon a diaphragm rupture. – Only rely on the diaphragm rupture sensor at back pres‐ sures greater than 2 bar. 21