Download Security Command XRSuper6 Installation guide

Transcript
INSTALLATION
6.7
XRSuper6/XR20/XR40 Standby Battery Calculations
Standby Battery Power Calculations
Command Processor Panel
Active Zones 1-9 (1-5 on XRSuper6)
Active Zone 10 (Zone 6 on XRSuper6)
2-Wire Smoke Detectors
Panel Bell Output
690/690F Security Command Keypad
692 Keypad
693 Easy Entry Keypad
790/790F Security Command Keypad
Active Zones (EOL Installed)
793 Easy Entry Keypad
Active Zones (EOL Installed)
770 Security Command Keypads
Active Zones (EOL Installed)
7060 Thinline/7060A Aqualite Keypad
7063 Thinline/7063A Aqualite Keypad
7070 Thinline/7070A Aqualite Keypad
Active Zones (EOL Installed)
7073 Thinline/7073A Aqualite Keypad
Active Zones (EOL Installed)
7760 Clear Touch Keypad
733 Wiegand Interface Module
Active Zones (EOL Installed)
734 Wiegand Interface Module
Active Zones (EOL Installed)
736P POPIT Interface Module
Radionics Popex, POPITs, OctoPOPITs
738A Ademco Wireless Interface Module
708 Bus Extender Module (one pair)
710 Bus Splitter/Repeater Module
714 Zone Expansion Modules
Active Zones (EOL Installed)
712-8 Zone Expansion Module
Active Zones (EOL Installed)
714-8, 714-16 Zone Expansion Module
Active Zones (EOL Installed)
715 Zone Expansion Module
Active Zones (EOL Installed)
2-Wire Smokes
715-8, 715-16 Zone Expansion Modules
Active Zones (EOL Installed)
2-Wire Smokes
iCOMSL Network Alarm Communicator
FA426 16-Point Receiver
Aux. Powered Devices on Terminals 7 and 11
Other than Keypads and Modules
Standby Current
Alarm Current
Qty ______ x 50mA ______mA
50mA ______mA
Qty ______ x 1.6mA ______
Qty ______ x *2mA ______
Qty ______ x
4mA ______
Qty ______ x 30mA ______
0.1mA ______
Qty ______ x 0.1mA ______
1500mA x
Max. ______
Qty ______ x 77mA ______
Qty ______ x 84mA ______
Qty ______ x 30mA ______
Qty ______ x 70mA ______
Qty ______ x 92mA ______
Qty ______ x 120mA ______
Qty ______ x 77mA ______
Qty ______ x 84mA ______
1.6mA ______
Qty ______ x *2mA ______
Qty ______ x 92mA ______
Qty ______ x 120mA ______
1.6mA ______
Qty ______ x *2mA ______
Qty ______ x 100mA ______
Qty ______ x 100mA ______
1.6mA ______
Qty ______ x *2mA ______
Qty ______ x 72mA ______
Qty ______ x 87mA ______
Qty ______ x 85mA ______
Qty ______ x 100mA ______
Qty ______ x 72mA ______
Qty ______ x 87mA ______
1.6mA ______
Qty ______ x *2mA ______
Qty ______ x 85mA ______
Qty ______ x 100mA ______
1.6mA ______
Qty ______ x *2mA ______
Qty ______ x 72mA ______
Qty ______ x 87mA ______
Qty ______ x 30mA ______
Qty ______ x 30mA ______
1.6mA ______
Qty ______ x *2mA ______
Qty ______ x 15mA ______
Qty ______ x 15mA ______
Qty ______ x 1.6mA ______
Qty ______ x *2mA ______
Qty ______ x 25mA ______
Qty ______ x 25mA ______
Qty ______ x ___mA ______
Qty ______ x ___mA ______
Qty ______ x 75mA ______
Qty ______ x 75mA ______
Qty ______ x 20mA ______
Qty ______ x 20mA ______
Qty ______ x 30mA ______
Qty ______ x 30mA ______
Qty ______ x
7mA ______
Qty ______ x
7mA ______
Qty ______ x 1.6mA ______
Qty ______ x *2mA ______
Qty ______ x 17mA ______
Qty ______ x 17mA ______
Qty ______ x 1.6mA ______
Qty ______ x *2mA ______
Qty ______ x 20mA ______
Qty ______ x 20mA ______
Qty ______ x 1.6mA ______
Qty ______ x *2mA ______
Qty ______ x
7mA ______
Qty ______ x
7mA ______
Qty ______ x
4mA ______
Qty ______ x *30mA ______
Qty ______ x .1mA ______
Qty ______ x
.1mA ______
Qty ______ x 20mA ______
Qty ______ x 20mA ______
4mA ______
*30mA ______
.1mA ______
.1mA ______
Qty ______
80mA ______
Qty ______
80mA ______
47mA ______
47mA ______
______mA
______mA
Total Standby ______mA
Total Alarm ______mA
Total Standby______mA x number of Standby Hours needed ______ = ________mA-hours
Total Alarm ______mA ________mA-hours
+
________mA-hours
* Based on 10% of active zones in alarm condition.
Total X .001
= ________Amp-hrs
Required
XRSuper6/XR20/XR40 Installation Guide
Digital Monitoring Products
7