Download Security Command XRSuper6 Installation guide
Transcript
INSTALLATION 6.7 XRSuper6/XR20/XR40 Standby Battery Calculations Standby Battery Power Calculations Command Processor Panel Active Zones 1-9 (1-5 on XRSuper6) Active Zone 10 (Zone 6 on XRSuper6) 2-Wire Smoke Detectors Panel Bell Output 690/690F Security Command Keypad 692 Keypad 693 Easy Entry Keypad 790/790F Security Command Keypad Active Zones (EOL Installed) 793 Easy Entry Keypad Active Zones (EOL Installed) 770 Security Command Keypads Active Zones (EOL Installed) 7060 Thinline/7060A Aqualite Keypad 7063 Thinline/7063A Aqualite Keypad 7070 Thinline/7070A Aqualite Keypad Active Zones (EOL Installed) 7073 Thinline/7073A Aqualite Keypad Active Zones (EOL Installed) 7760 Clear Touch Keypad 733 Wiegand Interface Module Active Zones (EOL Installed) 734 Wiegand Interface Module Active Zones (EOL Installed) 736P POPIT Interface Module Radionics Popex, POPITs, OctoPOPITs 738A Ademco Wireless Interface Module 708 Bus Extender Module (one pair) 710 Bus Splitter/Repeater Module 714 Zone Expansion Modules Active Zones (EOL Installed) 712-8 Zone Expansion Module Active Zones (EOL Installed) 714-8, 714-16 Zone Expansion Module Active Zones (EOL Installed) 715 Zone Expansion Module Active Zones (EOL Installed) 2-Wire Smokes 715-8, 715-16 Zone Expansion Modules Active Zones (EOL Installed) 2-Wire Smokes iCOMSL Network Alarm Communicator FA426 16-Point Receiver Aux. Powered Devices on Terminals 7 and 11 Other than Keypads and Modules Standby Current Alarm Current Qty ______ x 50mA ______mA 50mA ______mA Qty ______ x 1.6mA ______ Qty ______ x *2mA ______ Qty ______ x 4mA ______ Qty ______ x 30mA ______ 0.1mA ______ Qty ______ x 0.1mA ______ 1500mA x Max. ______ Qty ______ x 77mA ______ Qty ______ x 84mA ______ Qty ______ x 30mA ______ Qty ______ x 70mA ______ Qty ______ x 92mA ______ Qty ______ x 120mA ______ Qty ______ x 77mA ______ Qty ______ x 84mA ______ 1.6mA ______ Qty ______ x *2mA ______ Qty ______ x 92mA ______ Qty ______ x 120mA ______ 1.6mA ______ Qty ______ x *2mA ______ Qty ______ x 100mA ______ Qty ______ x 100mA ______ 1.6mA ______ Qty ______ x *2mA ______ Qty ______ x 72mA ______ Qty ______ x 87mA ______ Qty ______ x 85mA ______ Qty ______ x 100mA ______ Qty ______ x 72mA ______ Qty ______ x 87mA ______ 1.6mA ______ Qty ______ x *2mA ______ Qty ______ x 85mA ______ Qty ______ x 100mA ______ 1.6mA ______ Qty ______ x *2mA ______ Qty ______ x 72mA ______ Qty ______ x 87mA ______ Qty ______ x 30mA ______ Qty ______ x 30mA ______ 1.6mA ______ Qty ______ x *2mA ______ Qty ______ x 15mA ______ Qty ______ x 15mA ______ Qty ______ x 1.6mA ______ Qty ______ x *2mA ______ Qty ______ x 25mA ______ Qty ______ x 25mA ______ Qty ______ x ___mA ______ Qty ______ x ___mA ______ Qty ______ x 75mA ______ Qty ______ x 75mA ______ Qty ______ x 20mA ______ Qty ______ x 20mA ______ Qty ______ x 30mA ______ Qty ______ x 30mA ______ Qty ______ x 7mA ______ Qty ______ x 7mA ______ Qty ______ x 1.6mA ______ Qty ______ x *2mA ______ Qty ______ x 17mA ______ Qty ______ x 17mA ______ Qty ______ x 1.6mA ______ Qty ______ x *2mA ______ Qty ______ x 20mA ______ Qty ______ x 20mA ______ Qty ______ x 1.6mA ______ Qty ______ x *2mA ______ Qty ______ x 7mA ______ Qty ______ x 7mA ______ Qty ______ x 4mA ______ Qty ______ x *30mA ______ Qty ______ x .1mA ______ Qty ______ x .1mA ______ Qty ______ x 20mA ______ Qty ______ x 20mA ______ 4mA ______ *30mA ______ .1mA ______ .1mA ______ Qty ______ 80mA ______ Qty ______ 80mA ______ 47mA ______ 47mA ______ ______mA ______mA Total Standby ______mA Total Alarm ______mA Total Standby______mA x number of Standby Hours needed ______ = ________mA-hours Total Alarm ______mA ________mA-hours + ________mA-hours * Based on 10% of active zones in alarm condition. Total X .001 = ________Amp-hrs Required XRSuper6/XR20/XR40 Installation Guide Digital Monitoring Products 7