Download DCS WDU models Specifications
Transcript
UC864-E/G/WD/WDU AT Commands Reference Guide 80304ST10041a Rev. 7 - 2010-10-14 S7 - Connection Completion Time-Out <tout> - number of seconds 1..255 - factory default value is 60 ATS7? Read command returns the current value of S7 parameter. Reference 3.5.3.7.8. Note: the format of the numbers in output is always 3 digits, left-filled with 0s V25ter – Carrier Off With Firm Time - S10 S10 –Carrier Off With Firm Time ATS10 Execution command has no effect and is included only for backward compatibility with landline modems 3.5.3.7.9. Escape Prompt Delay - S12 S12 - Escape Prompt Delay ATS12=[<time>] Set command sets: 1) the minimum period, before receipt of the first character of the three escape character sequence, during which no other character has to be detected in order to accept it as valid first character; 2) the maximum period allowed between receipt of first or second character of the three escape character sequence and receipt of the next; 3) the minimum period, after receipt of the last character of the three escape character sequence, during which no other character has to be detected in order to accept the escape sequence as a valid one. Parameter: <time> - expressed in fiftieth of a second 20..255 - factory default value is 50. ATS12? Note: the minimum period S12 has to pass after CONNECT result code too, before a received character is accepted as valid first character of the three escape character sequence. Read command returns the current value of S12 parameter. Note: the format of the numbers in output is always 3 digits, left-filled with 0s Reproduction forbidden without Telit Communications S.p.A’s. written authorization - All Rights Reserved. Page 62 of 318