Download Carrier 50PD06 Unit installation

Transcript
measured
atemperature
above
268F(131C)orthethermistor
has the system controller providing the signal may not be powered.
short
circuited
(jumpered
out).
The DSC will de-energize
the compressor
contactor and unloader
TheDSCwillde-energize
thecompressor
contactor
andunloader solenoid and the alarm relay contacts will close causing a T051
solenoid,
andthealarm
relaycontacts
will close
causing
aT051 alert on the ComfortLink Control. Once the system controller
demand signal input has risen above 0.5VDC,
the ALERT code
alertontheComfortLink
Control. Thecompressor
will be
allowed
torestart
after30minute
delayandaftertheDTTreads and alarm relay output will reset. If the demand signal is above
1.44VDC
and the anti-short
cycle timer has timed out, the
below
250F(120C).Theflashcode
andalarm
relay
contacts
will
compressor
will
restart.
bereset
afterthecompressor
hasrunfor60minutes
without
any
otherALERTs.If five discharge
temperature
ALERTs
have Flash Code 6 -- Discharge Thermistor Fault
occurred
withinfourhours,
theDSCwilllockoutthecompressor. This occurs when the DSC is not receiving a signal from the
Thelockout
canonlybereset
bycycling
the24VAC
power
offand discharge temperature thermistor (DTT). The thermistor may be
on.
missing,
Flash Code 3 -- Compressor
Protector Trip
This occurs when the demand signal from the system
will close and the DSC will not increase
the capacity
of the
compressor
beyond 50% loading. This ALERT code and alarm
relay output are reset by reconnecting
the DTT.
controller
greater than 1.44VDC and there is no compressor
current
This could be due to the compressor's
internal overload
is
detected.
protector
being
open,
fuse or breaker
open,
power
disconnected
to
compressor
contactor,
compressor
power wiring not run through
DSC current transformer
port or a compressor
contactor failure.
The DSC will de-energize
the compressor
contactor and unloader
solenoid and the alarm relay contacts will close causing a T051
alert on the ComfortLink
Control.
The DSC will wait for the two
minute
anti-short
controller demand
compressor
the restart,
cycle timer to time out and if the system
signal is still greater than 1.44VDC, energize the
contactor
again. If compressor
current
the ALERT code and alarm relay output
is detected on
will reset. The
DSC will attempt to restart compressor
as long as the
controller demand is above 1.44VDC.
There is no lockout
for this ALERT.
Flash
Code
4 --
Locked
system
feature
Rotor
Flash
disconnected
Code
7 --Reserved
alarm relay
ComfortLink
contacts
will close causing
Control.
The
unloader
the 24VAC
5 --
power
Demand
off and on.
Signal
the
a T051
solenoid
alert
will
on the
remain
solenoid will de-energize
causing the compressor
to run loaded.
The ALERT code and alarm relay output are reset when current is
Flash
detected
Code
9 --
while
system
Low 24VAC
controller
demand
signal
is below
Supply
the supply
The DSC
voltage to the DSC has dropped
will de-energize
the compressor
contactor
and unloader
solenoid.
The alarm relay contacts may
close if the voltage is high enough for the alarm relay to pull in.
Loss
This occurs when the demand
signal input has dropped below
0.5VDC.
The demand input signal wire may be disconnected
or
Table
LED Flash
Code
when
energized
causing the compressor
to run unloaded
as long as the
system controller
demand
signal is less than 1.44VDC.
If the
system controller demand is greater than 1.44VDC,
the unloader
This occurs when
below
18.5VDC.
Flash Code
for future use
in this condition
since the DSC cannot open the compressor
contactor. The DSC will energize the compressor
contactor and the
contacts
Control.
cycling
relay contacts
system
controller
demand
signal
is below
1.44VDC.
The
compressor
contactor
may have welded contacts or the contacts
may be mechanically
jammed. The compressor
will continue to run
no longer
1.44VDC.
causing
a T051 alert on the ComfortLink
results in a lockout and can only be reset by
The alarm
Flash Code 8 -- Compressor
Contactor Fault
This occurs when the compressor
current is detected
A locked rotor condition
in the compressor
is sensed by the DSC
on four consecutive
start ups. The DSC will de-energize
the
compressor
contactor
and unloader
solenoid and the alarm relay
will close
This code
or a wire broken.
Description
The ALERT code and alarm relay output are reset when the supply
voltage to the DSC rises above 19.5VAC.
10 -- DSC Red LED
Flash Codes
Action Taken
by Control
Reset
Method
Probable Cause
N/A
N/A
N/A
1
Flash
Reserved for Future Use
2
Flash
High Discharge Temperature
Compressor
shutdown
Automatic
Compressor discharge temperature
degrees F or the DTT is shorted.
3
Flash
Compressor
Compressor
shutdown
Automatic
Compressor's internal overload protector being open,
fuse or breaker open, power disconnected to compressor contactor, compressor power wiring not run through
DSC current transformer port or a compressor contactor
failure.
4
Flash
Locked Rotor
Compressor
lockout
Manual
5
Flash
Demand Signal Loss
Compressor
shutdown
Automatic
Signal wire may be disconnected or the system controller providing the signal may not be powered
6
Flash
Discharge Thermistor
Capacity Limited
Automatic
DTT may be missing, disconnected
7
Flash
Reserved for Future Use
8
Flash
Compressor
9
Flash
Low 24VAC Supply
Protector Trip
Fault
Contactor Fault
N/A
N/A
Four consecutive
is greater then 268
start ups with locked rotor.
or a wire broken
N/A
Keep capacity
at 15%
Automatic
Compressor contactor may have welded contacts or the
contacts may be mechanically jammed
Compressor
shutdown
Automatic
Bad connection
32
or transformer.