Download Simrad MARINE COMPUTER - INSTALLATION REV A Installation manual
Transcript
Transducer Installation • minimum 6 mm wall thickness (4.5 mm if galvanised) If two or more transducers are installed close to each other it is possible to pull their cables in the same steel conduit, provided the conduit diameter is increased accordingly. However, for easy replacement it is recommended that each transducer has its own steel conduit. Handling and maintenance Note Do not lift the transducer by the cable. Do not expose the transducer to direct sunlight. Do not expose the transducer to excessive heat. Some transducers are delivered with a cover plate on the face for protection during transport. Let this plate stay on as long as possible, but do not forget to remove it before the vessel goes into the sea. An anti-fouling paint may be applied to the transducer face. Because some paint types may be aggressive to the polyurethane in the transducer face, please consult Simrad’s list of approved paints. Note Arctic tanks have acoustic windows made of polycarbonate. These must neither be painted nor cleaned with chemicals. During dry docking of the vessel, the transducer face may be cleaned for shells and other marine fouling. Be careful not to make cuts in the transducer face. Use a piece of wood or a very fine grade emery paper. 304699/A 141