Download Compaq A9890A - Smart Array 6402/128 RAID Controller QuickSpecs
Transcript
QuickSpecs HP Integrity rx8640 Server Configuration Configuration HP Integrity rx8640 Server Fully Loaded Configuration 16 Intel Dual core Itanium processor or 1.6 GHz Itanium processors 256 GB of Memory 16 PCI cards 4 cell boards 4 internal hard drives 2 DVD drives 2 Core I/O cards 6 bulk power supplies Typical maximum power: 3,962 VA (3,883 W) (19.81 A @ 200 VAC across 2 cords) Marked Electrical for the server: 5400 VA (30A @ 180 VAC across 2 cords) Marked Electrical per line cord: 2700 VA (15A @ 180 VAC across each cord) Maximum theoretical power: 5,982 VA (5,862 W) HP Integrity rx8640 Server Average Configuration 8 Intel Dual-core Itanium processors or Eight Intel Itanium processors 16 GB of Memory 8 PCI cards 2 cell boards 2 internal hard drives 1 DVD drives 2 Core I/O cards 3 bulk power supplies Typical power consumption: 1870 VA (9.35 A @ 200 VAC across 2 cords) Power Distribution Units 60 amp Power Distribution Unit AF916A (NA/JPN) and AF917A (International)–supported with 10K G2 rack E7683A (US) and E7684A (International)–supported in Rack System E A 60-amp Power Distribution Unit (PDU) has been developed for Integrity customers that prefer to use fewer, higher amperage connections into their wall electrical infrastructure. This PDU is sold separately and can be ordered with any HP Server solution. For more details on PDUs, please refer to the PDU sales collateral. The drawing below is an example of how the PDU can be configured with the HP Integrity rx8640 Server in a dual grid configuration. In this case there are two HP Integrity rx8640 servers (average configurations drawing ~9 amps each) and two 60-amp PDUs configured with redundant power. The blue cords represent the primary power connections needed for normal operation. In this example, cords from each server are plugged into a separate branch circuits. However, it is acceptable, for lower VA configurations, for each server to plug both grid A cords into one branch circuit and both grid B cords into second branch circuit. The remaining PDU outlets can be used to power other components as long as the specifications for the PDU rating are not exceeded. For redundant power inputs, the second set of red cords is added. If the second PDU is plugged into a second grid this configuration provides protection against: Losing power from a single power grid Accidental tripping of one or two circuit breakers DA - 12471 Worldwide — Version 14 — November 8, 2007 Page 21