Download Daikin FTY25CMA Service manual
Transcript
4. MODE OPERATION MODE M Press the key in current indication mode to go to MODE operation. All indication Lights on (for 3 sec.) Starting Preparation (for 18 sec.) ※1 Current indication (Operation state) MODE M MODE OPERATION In mode operation, the following settings/operations are available. 1. Generator setting Total power consumption can be reduced to desired Max setting for the specific generators set or power facilities. The selections are "off (No limit)", "15" "14" "13" "12" "11" KVA. 2. Automatic pump down Pump down can be executed automatically. (Refer to "Automatic pump down" in 4.4.3) 3. LED display Light-OFF (OPTION) All LED (includes LED lamp) can be switched off. In order to execute this function, initial setting (Refer to initial setting in 3.8.2) shall be required to change "on" position in advance. 4. Bulb mode setting Bulb mode setting can be executed in this mode. (N. Bulb mode control in 2.5.4) When "bulb" setting is "on", user can have opportunity to change the following set from default. qDehumidification: on/off (default) When "on" is selected, inside humidity can be set from 95% RH (default) to 60% RH, and is starting from 95%RH. wEvaporator fan speed : Alterating (H-L) (default)/High/Low eDefrost termination temperature (RS) +4.0~+18.0˚C (+5˚C : default) 3-12