Download Comtech EF Data MBT-4000 Product specifications
Transcript
MBT-4000 Multi-Band Transceiver System
Remote Control
Parameter
Type
Retrieve
Configuration
Status
Command
(Instruction
Code and
qualifier)
N/A
Valid on
MBT,
BDC, or
BUC
All
Revision 4
MN/MBT4000.IOM
Arguments
Description of Arguments
for Command
(Note that all arguments are ASCII numeric codes – i.e.,
or Response
ASCII codes between 48 and 57)
to Query
65 bytes
Query only.
(MBT-4000)
Used to Query the configuration status of the unit
98 bytes
Example for MBT-4000 base:
(BDC),
76 bytes
<0001/RCS?{cr}
(BUC)
>0001/RCS={cr}
alphanumeric
BF1=X {cr}
BF2=X {cr}
BT1=DN{cr}
BT2=UP{cr}
RED=0{cr}
RAM=00{cr}
MBT=N, A, or B
EXT=0{cr}{lf}
Response to
Command
(Target to
Controller)
N/A
Query
(Instruction
Code and
qualifier)
RCS?
Response to
Query
(Target to
Controller)
RCS=x….x
(see description
for details of
arguments)
Example for BDC or BUC:
<0001A1/RCS?{cr}
>0001A1/RCS={cr}
FLO=06300{cr}
ATT=01.00{cr}
MUT=1{cr}
SLP=0.3{cr}
LCS=0{cr}
LCW=99{cr}
LFL=1{cr}
REF=XXXX{cr} (reserved for future use)
XRE=X{cr} (reserved for future use)
AFR=0{cr}{lf}
Redundancy
State
RED=x
MBT
1 byte,
value of 0,1,
or 2
Note: For BUC, LCS, LCW, & LFL will not be shown.
Command or Query.
Controls redundancy state, where:
0=Off
1=Enables redundancy using single base unit
2=Enables redundancy using dual base units
Example: RED=1
A–18
RED= (message OK) RED?
RED? (received OK,
but invalid arguments
found)
RED* (message OK,
but not permitted in
current mode)
RED=x
(same format as
command
arguments)