Download Worcester 28i Junior Specifications
Transcript
Is the multiway connector at board position ST16 pushed fully home on to the board? 3. Technical Data No Push fully home Table 1. No Re-fix sensor onto pipe Yes Remove multiway connector from board position ST16. Test resistance across pins 16 and 17 ( yellow wire). Is it between 1 kOhm and 30 kOhm? 7.5 23.5 No Is there continuity from individual pins 16 and 17 to DHW sensor? No TEST E No 110 INTERNAL FIX mm 130 EXTENDED FLUE 275/*425 MAXIMUM LENGTH mm 725 MAXIMUM LENGTH mm 3000 FLUE ASSEMBLY DIAMETER mm 100 MAXIMUM LENGTH mm 3000 mm 1100 TERMINAL ASSEMBLY * NOTE : Minimum uncut length Table 3 Air pressure switch is shorting. Check tubes for blockage or replace switch. MAXIMUM AVAILABLE PUMP HEAD HEAD Metres MIN. FLOW RATE L/min. FLOW/RETURN DIFFERENTIAL °C 8 4.5 10.4 11 23.5 2.2 18.3 18 27.5 2.0 18.3 21 BOILER OUTPUT kW Yes No Table 4 MECHANICAL SPECIFICATIONS CENTRAL HEATING FLOW - COMPRESSION Yes mm MINIMUM LENGTH mm VERTICAL DUCT Yes No Repair or replace harness. EXTERNAL FIX VERTICAL FLUE Check or replace CH sensor. Test resistance across contacts to black & red cables. Is it between 30 and 90 ohms? Table 2. STANDARD FLUE No BOILER ADJUSTED FOR G31 (Propane) 9.5 3.4 30.0 35.3 LPG (Propane): Net Input = Gross Input x 0.921 WALL HOLE DIAMETER Yes Turn off electrical supply. Remove fan connector from board position ST1. Test resistance across contacts to black & white cables. Is it between 75 and 175 ohms? 8.0 27.5 HORIZONTAL FLUE Yes Test resistance across contacts 14 and 15 (green wire). Is it open circuit? BOILER ADJUSTED FOR G31 (Propane) 9.5 4.6 0.39 25.9 35.0 1.06 FLUE DETAILS Yes Is there continuity from individual contacts 12 and 13 to CH sensor? 28i NOMINAL BOILER RATINGS (10 Minutes After Lighting) BOILER ADJUSTED FOR G20 (Natural Gas) BURNER OUTPUT INPUT (Net) GAS RATE PRESSURE kW kW m bar. m3/h 8.0 9.5 1.2 1.00 27.5 30.0 14.7 3.17 Natural Gas: Net Input = Gross Input x 0.901 Repair or replace harness. Check or replace DHW sensor. Test resistance across contacts 12 and 13 (red wire). Is it between 1 kOhm and 30 kOhm? Table 1. NOMINAL BOILER RATINGS (10 Minutes After Lighting) BOILER ADJUSTED FOR G20 (Natural Gas) BURNER OUTPUT INPUT (Net) GAS RATE PRESSURE kW kW m bar. m3/h 7.5 9.5 1.4 1.00 23.5 25.9 13.6 2.74 Yes Check the DHW sensor. Is it correctly fitted onto the pipe with heat conductive paste between the pipe and sensor? 24i Check/repair fan harness or repalce fan. Yes RETURN - COMPRESSION 22mm 22mm 15mm 15mm DOMESTIC WATER FLOW - COMPRESSION 15mm 15mm 3 Rp ⁄4 3 Rp ⁄4 RELIEF VALVE DISCHARGE 15mm 15mm CASING HEIGHT 600mm 600mm CASING WIDTH 400mm 440mm CASING DEPTH 325mm 325mm WEIGHT - LIFT 22kg 23.5kg WEIGHT - PACKAGED 37kg 40kg WEIGHT - DRY 40 28i 22mm COLD WATER INLET - COMPRESSION GAS INLET No 24i 22mm 34.7kg 5 37.5kg 0.39 1.23