Download Comtech EF Data CDM-710G Product specifications

Transcript
CDM-710G High-Speed Satellite Modem
Remote Control
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Rx Gold Code
Sequence Index
RGS=
6 bytes
Rx Interface
Enable
RIE=
2 bytes
Retrieve next 5
unread Stored
Events
N/A
75 bytes
Rx Pilot On/Off
N/A
1 byte
Revision 1
MN-CDM710G
Description of Arguments
Command or Query.
Rx Gold Code Sequence Index:
xxxxxx = Gold Code Sequence index ( 0 to 262141 )
Example: RGS=189063
Command or Query.
Interface Slot Enable/Disable, where:
s=Defines which interface slot (1 or 2)
x=Rx Interface Status, where:
0=Disabled
1=Enabled
Example: RIE =11 (Enables receive interface)
Query Only.
Unit returns the oldest 5 Stored Events which have not yet been read over
the remote control in the form: {CR}Sub-body{CR}Sub-body{CR}Subbody{CR}Sub-body{CR}Sub-body, where Sub-body= ABCddmmyyhhmmss:
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Log
C is Fault Code numbers, as in FLT? or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
If there are less than 5 events to be retrieved, the remaining positions are
padded with zeros. If there are no new events, the response is RNE*.
QueryOnly .
Rx Pilot On/Off selection, where:
0=Off,
1=On
Example: RPI=0 (which is Pilot Off)
Returns RPI=x if Demodulator unlocked.
This is automatically detected on demod acquisition.
A–41
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
RGS=
RGS?
RGS*
RGS#
RGS?
RGS=xxxxxx
RIE=
RIE?
RIE*
RIE#
RIE?s
RIE=sx
RNE?
RNE*
RNE#
RNE?
RNE={CR}ABCddmmyyh
hmmss{CR}ABCddmmyy
hhmmss{CR}ABCddmmy
yhhmmss{CR}ABCddmm
yyhhmmss
{CR}ABCddmmyyhhmms
s
N/A
RPI?
RPI=x