Download Vaillant 628/2 E Technical data
Transcript
4 General Requirements Vessel Volume [L] 1.0 1.5 3.0 700 Lift [mbar] Initial system pressure (bar) Pressure relief valve setting (bar) Total water content of system ltres 25 2.7 3.9 50 5.4 7.8 100 10.9 15.6 125 13.6 19.5 650 600 550 500 450 400 350 300 150 16.3 23.4 175 19.1 27.3 200 21.8 31.2 Pump switch in position III (pre-delivery setting) 250 200 150 Pump switch in position II 100 50 225 24.5 35.1 250 27.2 39.0 275 30.0 42.9 300 32.7 46.8 325 35.7 50.7 350 38.1 54.6 375 40.9 58.5 400 43.6 62.4 425 46.3 66.3 450 49.0 70.2 475 51.8 74.1 500 For system volumes other than those given above, multiply the system volume by the factor across 54.5 78.0 0.109 0.156 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 Volume flow [l/min] Fig. 4.6: Pump specifications 37 kW 4.8.7 System by-pass An automatic system by-pass is included within the boiler. The boiler is suitable for use in systems with thermostatic radiator valves and no additional by-pass is required. 4.8.8 Venting The boiler is fitted with an automatic air vent. Additional provision should be made to enable the heating system to be vented during filling and commissioning either by automatic air vents or manually. 4.8.6 Circulating pump The circulating pump is included in the boiler. The pump head available for the heating system is shown in fig. 4.6. Lift [mbar] 700 650 600 550 500 450 400 350 300 Pump switch in position III (Factory setting) 250 200 150 Pump switch in position II 100 50 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Volume flow [l/hr] Fig. 4.6: Pump specifications 12-28 kW 14 Instructions for Installation and Servicing turboMAX plus and thermoCOMPACT R1