3.0 3.1 BOILER OPERATION CENTRAL HEATING 1. With a demand for heating, the pump, circulates water through the primary circuit. 2. Once the main burner ignites the fan speed controls the gas rate to maintain the heating temperature measured by the temperature sensors. 3. When the demand is satisfied the burner is extinguished and a 5 minute delay occurs before the burner will re-light (anticycling), the pump continues to run for a period of 2 minutes (Pump Overrun). 3.2 FROST PROTECTION MODE 1. Providing there is mains power supply to the appliance, the frost protection mode is integral. If the system temperature falls below 5°C then the boiler will fire on its minimum setting until a flow temperature of 20°C is reached. Further protection can be incorporated by using a system frost thermostat. 3.3 Manual Bleed Valve Fig. 3 PUMP PROTECTION Flue Products 1. The pump will automatically operate for 1 minute in every 24 hours to prevent sticking. Expansion Vessel Burner & Burner Flange Primary Heat Exchanger CH flow Thermistor CH return Thermistor Primary Return Automatic Air Vent CH Flow Condensate Trap Pump & Hydroblock 3 BAR Pressure Relief Valve Pressure Gauge CH Return 8 © Dimplex Boilers 2008