RPM Display and Visual Metronome/Pulse Initial operation The metronome (the two green LED bars in the middle) flashes once per handle stroke at a preset rate. The two green LED bars in the middle can also be set to show pulse. It makes one flash for every heart beat. Crank handle frequency compared to metronome rate is always shown. Although all 831 E ergometers are 100 % calibrated at the factory, the user may wish to verify this by performing the mechanical calibration of the pendulum weight. See section ”Calibration of Pendulum Weight”. Underspeed: Crank handle speed is lower than desired metronome rate. 2, 4, 8, 16 or more depending on which LED bar that indicates. Apply power to the ergometer by first connecting the cable from the power adaptor to the ergometer at the front connector labelled “24VAC/18VAC“. Then plug the power adaptor into the wall outlet. Turn the power switch to “On”-position. A green LED indicates power to the 831 E. Overspeed: Crank handle speed is greater than desired metronome rate. 2, 4, 8, 16 or more depending on which LED bar that indicates. Perform the electrical calibration as specified in section ”Electronic calibration”. Test run the ergometer. The Ergometer 831 E is now fully functional and ready to use. RPM 16 8 42 Metro/Puls 16 8 4 2 Height adjustment of table stand The height of the table stand can be adjusted to get the ergometer at the desired level by using the crank at the stand. To adjust the height on the table stand, pull out the crank and crank it until the desired height is reached. To lock the table stand, push the crank again. See fig: Table stand. Fig: Rpm display 1 1 3 Fig: Table stand Height adjustable crank (1) Monark 831 E 7