Download ASTi Telestra User guide
Transcript
ASTi Telestra User Guide (Ver. 3, Rev. G.1) Time: Maximum Poll Interval Used with Minimum Poll Interval to specify a range of acceptable intervals when the Telestra NTP client will synchronize with the NTP server. In the client, this translates into seconds: two to the power of this setting. The allowable range is 4 (16 s) to 17 (36.4 h) inclusive. As an NTP server becomes more accurate and reliable over the lifetime of synchronization history, the NTP client will poll it less frequently. This setting specifies the longest amount of time the Telestra NTP client will wait before synchronizing with the server. Default for this setting is 10 (17 m, 4 s). If the max. poll interval is set lower than the min. poll interval, Telestra will use system defaults. Copyright © 1999-2006 Advanced Simulation Technology inc. 85