Hard Disk Drive Tray – 525 MB Seagate Drive (ST3600N) 525 MB Seagate drive SCSI interface termination The Seagate drives have the capability to provide termination for the SCSI interface cable. This feature is not needed for the AXM application since a terminator is placed at the end of the SCSI cable network on the HDDT I/O board. The diagram illustrates the missing termination resistor modules on the drive. Replacement drives may have these resistor modules in place. Remove them if they are present. This applies to both possible drives in the disk tray. Notice that the drive is shown upside down. You cannot see the terminator resistor module locations once the drive is installed. No SCSI Bus Termination Resistor Modules 40036 12/01 Application ModuleX Service Honeywell 69