Download Emerson Oxymitter 4000 Specifications

Transcript
1-6.
SPECIFICATIONS.
Oxymitter 4000
O2 Range:
Standard ............................................................
Accuracy ....................................................................
System Response to Calibration Gas .......................
Temperature Limits:
Process ...............................................................
Electronics ........................................................
Probe Lengths ...........................................................
Mounting and Mounting Position ...........................
Materials:
Probe .................................................................
Electronics Enclosure .......................................
Calibration ................................................................
Calibration Gas Mixtures Recommended ..............
Calibration Gas Flow ...............................................
Reference Air ............................................................
Electronics .................................................................
Electronic Noise ........................................................
Line Voltage ..............................................................
Signals:
Analog Output/HART .....................................
Logic I/O ...........................................................
0 to 10% O2
0 to 25% O2
0 to 40% O2 (via HART)
±0.75% of reading or 0.05% O2, whichever is greater
Initial response in less than 3 seconds T90 in less than 8
seconds
32° to 1300°F (0° to 704°C) up to 2400°F (1300°C) with
optional accessories
-40° to 185°F (-40° to 85°C)
Operating temperature of electronics inside of instrument
housing, as measured by a HART communicator or
Rosemount Asset Management Solutions software.
18 in. (457 mm)
3 ft (0.91 m)
6 ft (1.83 m)
9 ft (2.74 m)
12 ft (3.66 m)
Vertical or horizontal
Spool pieces are available, P/N 3D39761G02, to offset
transmitter housing from hot ductwork.
Wetted or welded parts - 316L stainless steel
Non-wetted parts - 304 stainless steel, low-copper
aluminum
Low-copper aluminum
Manual, semi-automatic, or automatic
0.4% O2, Balance N2
8% O2, Balance N2
5 scfh (2.5 l/m)
2 scfh (1 l/m), clean, dry, instrument-quality air
(20.95% O2), regulated to 5 psi (34 kPa)
NEMA 4X, IP66 with fitting and pipe on reference exhaust
port to clear dry atmosphere
Meets EN 50082-2 Generic Immunity Std. Part II.
Includes EN 61000-4-2 for Electrostatic Discharge
4 KV contact, 8 KV in air
Includes IEC 801-4 for fast transients; 2 KV on power supply and control lines
90-250 VAC, 50/60 Hz. No configuration necessary 3/4 in.
- 14 NPT conduit port
4-20 mA isolated from power supply, 950 ohms maximum
load
Two-terminal logic contact configurable as either an alarm
output or as a bi-directional calibration handshake signal to
IMPS 4000 or SPS 4000
Self-powered (+5 V), in series with 340 ohms
Conduit ports — 3/4 in.-14 NPT (one threaded hole for
both analog output and logic I/O)
IB-106-340
1-8