Download Emerson Oxymitter 4000 Specifications
Transcript
1-6. SPECIFICATIONS. Oxymitter 4000 O2 Range: Standard ............................................................ Accuracy .................................................................... System Response to Calibration Gas ....................... Temperature Limits: Process ............................................................... Electronics ........................................................ Probe Lengths ........................................................... Mounting and Mounting Position ........................... Materials: Probe ................................................................. Electronics Enclosure ....................................... Calibration ................................................................ Calibration Gas Mixtures Recommended .............. Calibration Gas Flow ............................................... Reference Air ............................................................ Electronics ................................................................. Electronic Noise ........................................................ Line Voltage .............................................................. Signals: Analog Output/HART ..................................... Logic I/O ........................................................... 0 to 10% O2 0 to 25% O2 0 to 40% O2 (via HART) ±0.75% of reading or 0.05% O2, whichever is greater Initial response in less than 3 seconds T90 in less than 8 seconds 32° to 1300°F (0° to 704°C) up to 2400°F (1300°C) with optional accessories -40° to 185°F (-40° to 85°C) Operating temperature of electronics inside of instrument housing, as measured by a HART communicator or Rosemount Asset Management Solutions software. 18 in. (457 mm) 3 ft (0.91 m) 6 ft (1.83 m) 9 ft (2.74 m) 12 ft (3.66 m) Vertical or horizontal Spool pieces are available, P/N 3D39761G02, to offset transmitter housing from hot ductwork. Wetted or welded parts - 316L stainless steel Non-wetted parts - 304 stainless steel, low-copper aluminum Low-copper aluminum Manual, semi-automatic, or automatic 0.4% O2, Balance N2 8% O2, Balance N2 5 scfh (2.5 l/m) 2 scfh (1 l/m), clean, dry, instrument-quality air (20.95% O2), regulated to 5 psi (34 kPa) NEMA 4X, IP66 with fitting and pipe on reference exhaust port to clear dry atmosphere Meets EN 50082-2 Generic Immunity Std. Part II. Includes EN 61000-4-2 for Electrostatic Discharge 4 KV contact, 8 KV in air Includes IEC 801-4 for fast transients; 2 KV on power supply and control lines 90-250 VAC, 50/60 Hz. No configuration necessary 3/4 in. - 14 NPT conduit port 4-20 mA isolated from power supply, 950 ohms maximum load Two-terminal logic contact configurable as either an alarm output or as a bi-directional calibration handshake signal to IMPS 4000 or SPS 4000 Self-powered (+5 V), in series with 340 ohms Conduit ports — 3/4 in.-14 NPT (one threaded hole for both analog output and logic I/O) IB-106-340 1-8