Download Enigma video processor User manual
Transcript
Code: ENIGMA III User Manual Edition: 1 Revision: 4 Date: 19/12/2008 Page: 62/97 Type: Default: float 0.0 Remark: The offsets are only used for lowpass receivers (video processing) as the A/D converter offset is effectively canceled by the matched bandpass filter. 6.13 PRFTable Format of argument: staggering prf1 prf2 ... prf8 If staggering=0, only prf1 is used, otherwise dual PRF mode is used. Eight PRF values are reserved for four pulse widths. PRF values are paired, every pair assigned for the corresponding pulse width. Higher and lower PRFs are determined automatically, order in the pair is not important. Default PRF is 600 for all pulse widths, no staggering. Example: set PRFTable=1 600 400 1200 800 300 200 600 400 6.13.1 PrfLimits The duty cycle of the magnetron must not be exceeded. In case of an old radar which uses a now obsolete PFN the PRF must also not be too low, as this could damage the PFN. Format of argument: 4x low PRF and 4x high PRF limits Default: 250 250 250 250 400 400 400 400 This parameter has to be set to ensure that the PRF (and the resulting duty cycle when switching PRF) is hardware limited by the signal processor. Current pulse width is choosen by parameter PulseWidthIndex. 6.14 PulseWidthIndex Index of the current pulse width. It is in range 0-3. Type: Default: integer 0 6.15 NOISEThreshold Positive value in dB. Type: Default: float 0.0 GAMIC Proprietary