Download A&D FX-1200iWP Specifications
Transcript
Dust & Water-Proof Precision Balances FZ-iWP iWP FX-Series ISO 9000 CERTIFIED ...Clearly a Better Value http://www.aandd.jp The World’s First IP65 Compliant, Dust & Water-Proof W Water-Pro oof Precision Precis i ion (1 mg) Balances e Yet another breakthrough from A&D enabling the measurement of powder or liquid at 1 mg resolution, eliminating any worries about damage to the balance! What does “IP65” mean? An International Protection (IP) Code, as defined by the international standard IEC 60529, specifies the degrees of protection provided by enclosures. The two digits next to IP indicate the levels of protection against solid foreign objects (first digit) and water (second digit). For example, a device rated as IP65 should permit no ingress of dust (level 6) and withstand water jetting from any direction (level 5). Newly Developed, Air-Pump Controlled Internal Calibration i (FZ-iWP models only) * i Patent Pending For the internal calibration of the FZ-iWP Series, A&D adopted a direct-driving method that utilizes air pressure for its power source. This new method features a simple structure, high reliability and a fail-safe mechanism – the internal mass returns to the original position even if the calibration is interrupted by power failure, etc. One Touch Automatic Calibration (FZ-iWP models only) With just one press of a key, you can ensure the accuracy of your balance. Super Hybrid Sensor VFD Display Quick USB LAN-Ethernet Interface RS-232C Interface GLP Compliant Counting Function Auto Power OFF Underhook Rechargeable Battery IP65 Software Animal Weighing Percentage Function Statistical Calculation ON Comparator Function Auto Power ON Internal Calibration EC Type Approval (FZ-iWP) External Calibration (FX-iWP) Compact, B5 Size Footprint A&D’s latest, Compact Super Hybrid Sensor (C-SHS) technology ii has significantly reduced the size of the FZ-iWP/FX-iWP Series – a 25% smaller footprint than the GX/GF Series – making it ideal for installation and use in narrow spaces. * ii Patent Pending Fast, 1 Second Stabilization While maintaining extremely high span stability, the C-SHS also realizes an ultra-fast response speed – just 1 second – to maximize your productivity and efficiency. RS-232C Interface (standard) Bi-directional communication is possible with a PC, printer or other peripheral device. Dust & Water-Proof RS-232C Cable (optional) Quick USB Interface (FXi-02) The easy-to-use optional USB interface requires no driver or software installation for iii transfer of weighing data to a PC. LAN-Ethernet Interface (FXi-08) with WinCT-Plus Software The user can send commands for controlling and acquiring data from multiple balances. WinCT-Plus LAN USB Ethernet Hub Provided by end-user FX i -08 FX i -08 FX i -02 FX i -08 communication from a balance to a * iii Unidirectional PC only. Please use the standard RS-232C interface to send commands from a PC to the balance. Shock Absorber Functioniv The internal shock absorber protects the C-SHS from the adverse effects of vertical and transverse overloading. * iv Patent Pending Multiple Weighing Units Programmable or standard weighing units of measurement can be selected: g, pcs, %, oz, lb, L oz, ozt, ct, mom, dwt, GN, tl, tol, mes, and MLT. Statistical Calculation Function The balance displays and/or outputs statistical calculation data as No. (number of data), SUM (total), MAX (maximum), MIN (minimum), R [range (maximum – minimum)], AVE (average), SD (standard deviation) and CV (coefficient of variation). Built-in Rechargeable Battery (FXi-09) An optional Ni-MH rechargeable battery pack can be fitted into the balance for use without AC power and for mobile applications (10 hours charging time for 8 hours operation). Large Breeze Break Note: (FXi-WP-11) All FZ-iWP models, the FX-120iWP, the FX-200iWP and the FX-300iWP come with a small breeze break as standard. Specifications FZ-120iWP FX-120iWP 122g Weighing capacity FZ-200iWP FX-200iWP FZ-300iWP FX-300iWP 220g 320g Minimum weighing value 0.001g Counting mode 0.001g Minimum unit mass 1220g 2200g 3200g 0.01g 0.01g 5, 10, 25, 50 or 100 pieces Number of samples Percent mode FZ-1200iWP FZ-2000iWP FZ-3000iWP FX-1200iWP FX-2000iWP FX-3000iWP 0.100g Minimum 100% reference mass 1.00g 0.01%, 0.1%, 1% (depends on the reference mass stored) Minimum 100% display Repeatability (Standard Deviation) Linearity 0.001g 0.01g ±0.002g ±0.02g Approx. 1 second Stabilization time (typically set at FAST) ±2ppm / °C Sensitivity drift (10°C to 30°C) 5°C to 40°C (41°F to 104°F), 85%RH or less (no condensation) Operating temperature Vacuum Fluorescent Display (VFD) Display type 5 times /second, 10 times /second or 20 times /second Display refresh rate RS-232C Interface Standard interface 130mm Weighing pan (diameter) 150mm Air-pump Controlled Internal Calibration (FZ-i WP models only) Internal calibration External calibration mass 100g 200g 300g 1000g 2000g 3000g 50g 100g 200g 500g 1000g 2000g 100g Approx. 11VA (supplied to the AC adaptor) Power consumption 193 (W) X 262.5 (D) X 85.5 (H) mm External dimensions FZ-i WP Approx. 3.2kg / FX-i WP Approx. 2.7kg Net weight Pan size A 168.5 / 6.63 162 / 6.38 Accessories 61.5 / 2.42 *Underhook Dimensions with Small Breeze Break (FX i-WP-10) 193 / 7.6 (Comes equipped with FZ,FX-120iWP/200iWP/300iWP, FZ-1200iWP/2000iWP/3000iWP) 184 / 7.24 184 / 7.24 168.5 / 6.63 171.5 / 6.75 175 / 6.89 ø130 / 5.12 115 / 4.53 262.5 / 10.33 115 / 4.53 81 / 3.19 83.5 / 3.29 Static eliminator Electrostatic fieldmeter Weighing data logger Tweezers for calibration weight Remote display Remote controller Compact printer Universal printer Serial/Ethernet converter Quick USB adapter Serial/USB converter Waterproof RS-232C cable (5m) Carat pan (silver, 2pcs) Carat pan (black, 2pcs) Main unit cover (5pcs) 194.5 / 7.66 192* 3* 85.5 / 3.33 85 / 3.35 AD-1683 AD-1684 AD-1688* AD-1689 AD-8920A* AD-8922* AD-8121B* AD-8118C* AD-8526* AD-8527* AX-USB-9P* AX-KO2737-500-EX AX-CARATPAN-W AX-CARATPAN-B AX-FXi-31 A 130 / 5.12 150 / 5.91 262.5 / 10.33 Model FZ,FX-120iWP / 200iWP / 300iWP FZ,FX-1200iWP / 2000iWP / 3000iWP 70.5 / 2.78 Quick USB interface with cable Ethernet interface with WinCT-Plus software Built-in rechargeable battery Small breeze break (gray) Large breeze break (gray) Animal weighing pan Carrying case FXi-02, FXi-08 and FXi-09 cannot be used at the same time * (Not IP65 compliant when used with FZ,FX-i WP) Dimensions with Large Breeze Break (FX i-WP-11) (Not IP65 compliant when used with FZ,FX-i WP) 105/4.13 112/4.41 294/11.57 199.5/7.85 193/7.6 315/12.4 * 193 / 7.6 External Dimensions (mm/inches) 85.5 / 3.37 Options FXi-02* FXi-08* FXi-09* FXi-WP-10 FXi-WP-11 FXi-12 FXi-15 1000g Confirm that the adaptor type is correct for the local voltage and power receptacle AC adaptor Ø156/6.14 FXi-12 107/4.21 ...Clearly a Better Value *FZi/FXiWP-ADCC-01-PR1-09703 GX GF Series GX-400 with optional glass breeze break GX-600 with standard breeze break ISO 9000 CERTIFIED http: //www. aandd. jp Our revolutionary Super Hybrid Sensor (SHS) technology improves response speed, accuracy and minimizes maintenance costs. SHS combines the best of magnetic force restoration and single point parallelogram load sensing technologies. Its unique design provides the fastest response speed in its class – just 1 second! And if the time ever comes when the SHS needs repair, you just replace one of three parts – there is no need to replace the whole sensor! This translates to Minimum Maintenance Costs. (An additional benefit of our new SHS is that the GX automatically performs self calibration using the internal mass when the balance detects ambient temperature changes.) Super Hybrid Sensor Motor-driven Internal Calibration ( Patent Pending ) Internal Calibration The GX internal calibration with an internal mass saves time and money. External calibration requires a great deal of skill, time and an expensive external mass. With our internal calibration with internal mass, the balance is calibrated very quickly. ❚ Automatic Self Calibration — Self-calibrates automatically when the balance detects ambient temperature changes. ❚ One Touch Automatic Calibration — Allows you to calibrate the balance on demand with just the push of a button. ❚ Calibration is essential for accuracy in weighing. For example, in high resolution balances, changes in sensitivity drift can be caused by changes in the ambient temperature. Take the GX 600 for example, the weight might change by ±0.010g with a change of 10°C. (Sample’s weight: 500g) ❚ The GX’s internal calibration mass is adjusted to an “OIML F1 class level.” by the standard balance calibrated with an “OIML E2 class level mass”. (The GX’s internal calibration mass is not “the standard mass for legal metrology” nor “OIML’s level of calibration mass.” Instead it is the mass for adjustment.) Just 1 Second — Ultra Fast Response Speed ❚ Ultra Fast Response Speed–Just 1 Second.* Ideal for installation with filling machines. * “FAST” setting ❚ Ultra High Performance with minimum maintenance costs. Standard RS-232C Incorporates bi-directional communication with a PC, printer or other peripheral device. Standard Windows Communication Tools Software WinCT A free copy of WinCT-A&D's powerful and flexible data collection software tool for virtually instant connection to a PC and a network of other devices. GX GF OFF VFD Display Bright, bold, blue vacuum fluorescent display ( VFD ) that is virtually unmistakable from any viewing angle. Animal Weighing Mode allows you to quickly and accurately determine the weight of any live or unstable subject. Optional animal weighing pan (GX-12) is available. Automatic Adjustable Environment Setting Standard Comparator Function Manual Response Adjustment can be set by pressing the MODE key and response speed can be adjusted to FAST, MID or SLOW. offers increased flexibility and compatibility for a vast number of applications. You can input a target weight and weigh heavier or lighter items using either the keyboard or by placing samples on the pan. Hi, OK or Lo will be indicated on the display to show the comparison results. (GX-04 Comparator output ) Percentage Overall Capacity Indication Adapts to the most suitable Environment Response Setting automatically with one-touch key operation. The response annunciator displays “FAST”, “MID” and “SLOW.” (GX) Automatic Counting Accuracy Improvement (ACAI) is a novel and useful approach to ensuring the utmost in performance when counting even the smallest of items. ACAI automatically updates and refines the average piece weight used to determine the total quantity. Function facilitates an effective and quick comparison of a sample or commodity against a known reference mass. Simply place an object on the pan to register its weight as 100%. Place another object on the pan to compare its weight in percentage mode. Main Features SHS (Super Hybrid Sensor) Internal Calibration VFD Display WinCT Data Memory Function Automatic Adjustable Environment Setting Auto Self Checking Density Determination Function Quick Reference Card Underhook Time & Date Function Large Square Weighing Pan Comparator Function Animal Weighing Capacity Indicator ACAI Counting Function Percentage Function Front Air Bubble Leveling Standard RS-232C GLP, GMP, GCP, ISO Compliance Data Output Splash Proof Keyboard and Display Display Auto Power Off Function Aluminum Die-Cast Case GX series ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ is a unique and helpful feature. By indicating how much of the balance's capacity has been filled, the risk of overloading the balance is minimized. GF series ✔ —— ✔ ✔ ✔ ( Manual ) ✔ ✔ ✔ ✔ —— ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Splash Proof Keyboard and Display Auto Self Checking Balances protected from dust and spills Automatically checks itself when setting the Automatic Adjustable Environment GLP/GMP/GCP/ISO Compliance Allows GLP or LIMS balance management by outputting the Balance ID number and data used to calibrate the balance. The data can be output to A&D’s AD–8121B printer or a computer, indicating date, time, Balance ID number, serial number and calibration data. Standard Underhook Ideal for density determination and weighing magnetic substances. Density Measurement Function Picture shown with GX-13 Density Measurement Kit Standard RS-232C Interval Time Setting Bi-directional communication with a PC or connects directly to a printer Weighing intervals of 2, 5, 10, 30 seconds and 1, 2, 5, 10 minutes in the Data Memory Function Commands Auto Power On Function A PC can control the balance by sending commands to the balance. • Commands to query weighing data • Commands to control the balance • Commands to control the memory function • Commands to control the comparator function Plug it in and it turns itself on without pressing ON/OFF key STANDARD ID Number The balance ID number can be set. It is used to identify the balance when GLP is used. The ID number is memorized and maintained once it is fixed, even if the AC adapter is removed. OFF Display Auto Power Off Function Display turns off after 10 minutes of inactivity ( can be disabled when undesired ) Data Memory Function ( Patent Pending ) Format the Data Memory Function for: GX • 200 sets of weighing data • 100 sets of weighing data with Time & Date • 50 sets of GLP Data–Time & Date, Calibration Data, ID number and Serial number • 20 sets of Unit Weight for Counting Mode GF • 40 sets of weighing data • 20 sets of Unit Weight for Counting Mode Time & Date (GX only) Standard Time & Date Function complies with GLP and Interval Weighing in the Data Memory Function Auto Re-Zero Function Re-Zeroes automatically after data output Large Square Weighing Pan Standard large square weighing pan on all models 128 x 128mm for 0.001g resolution models 165 x 165 mm for 0.01g and 0.1g resolution models Multiple Weighing Units & Programmable Unit Uses Programmable or standard units of measure ( g, ct, dwt etc.) Front Air Bubble Leveling Easily check the balance’s level from the front Quick Reference Card A fast, convenient operating guide installed at the bottom of the balance Specifications Weighing capacity GX-200 GX-400 GX-600 GX-800 GX-1000 GX-2000 GX-4000 GX-6100 GX-6000 GX-8000 GF-200 GF-300 GF-400 GF-600 GF-800 GF-1000 GF-1200 GF-2000 GF-3000 GF-4000 GF-6100 GF-6000 GF-8000 210g 310g 410g Stabilization time (typical at FAST) 810g 1100g 1210g 2100g 3100g ±0.003g Approx. 1second Approx. 1.5 seconds 0.1g ± 0.02g Approx. 1second ±0.03g ± 0.1g Approx. 1.5seconds Approx. 1second ± 5ppm/°C (auto-self calibration OFF) Super Hybrid Sensor (SHS) *SHS: Patent issued and pending Display type Vacuum Fluorescent Display (VFD) Display refresh rate 5times/second or 10times/second 0.001g Counting Minimum unit mass mode Number of samples 0.01g 0.1g 1.00g 10.0g 10, 25, 50 or 100pieces 0.100g Minimum 100% reference mass 0.01%, 0.1%, 1% (Depends on reference mass stored) Minimum 100% display RS-232C Interface with Windows Communication Tools ( WinCT: included as CD-ROM) Standard serial I/F 128 x 128mm (5.04 x 5.04 inch) 165 x 165 mm (6.50 x 6.50 inch) Motor-driven Internal Calibration (GX only) Calibration 210(W) x 317(D) x 86(H)mm (8.27 x 12.48 x 3.39inch) External dimensions Confirm that the adapter type is correct for the local voltage and power receptacle Approx. 11VA (supplied by AC adapter) Power consumption Net weight 8100g 5°C to 40°C (41°F to 104°F), 85%RH or less (No condensation) Sensing method AC adapter 6100g 0.1g ±2ppm/oC (When automatic self calibration is not used) Operating temperature Weighing pan 6100g 0.01g ± 0.002g Sensitivity drift (10°C to 30°C/50°F-80°F) Percent mode 4100g 0.01g 0.001g Repeatability (Standard Deviation) Linearity 610g 0.001g Minimum weighing value Approx. 4.6kg(GX)/3.8kg (GF) Approx. 5.1kg (GX) / 4.3kg (GF) Notes: The internal mass is equal to (approximately) 500grams. EC Type Approval Confirmed (Approval No. UK2560) Standard Breeze break included for 1mg Minimum weighing value models Dimensions With Optional Glass Breeze Break (mm) 454.3 317 210 163 244 A GX-04* Comparator Output with a Buzzer/ RS-232C/Current Loop Output GX-06* Analog Output /Current Loop Output GX-10 Glass Breeze Break for 128 x 128mm weighing pan size models GX-11 Glass Breeze Break for 165 x 165mm weighing pan size models GX-12 Animal weighing pan (not applicable for GX-200 and GF-200) GX-13 Density Determination Kit for 128 x 128mm weighing pan size models 04& 06 cannot co-exist Factory installed option 28 Physical Dimensions (mm) 317 Options 162.5 45 * * 210 Accessories 231.3 141 195.5 176 207.5 Pan size (mm) Model GX-200/400/600/800/1000 GF-200/300/400/600/800/1000 A B 162.5 128 128 GX-2000/4000/6100/6000/8000 GF-1200/2000/3000/4000/6100/6000/8000 165 165 86 Dot Matrix Compact Printer Universal Printer Remote Display Remote Controller Rechargeable Battery Unit (Maximum operating time: 8hours) AD-1683EX Static Eliminator AX-KO1710-200 RS-232C Cable (25P-9P) AX-SW-128 Foot Switch AX-073003691-S Dust cover for 128 x 128mm weighing pan size models AX-073003692-S Dust cover for 165 x 165mm weighing pan size models 86 B AD-8121B AD-8118B AD-8920 AD-8922 AD-1682 Approx. 1 second Specifications subject to change for improvement without notice. ...Clearly a Better Value * GX/GF-ADCC-05-PR5-05c05 GX-K GF-K Series GF-K GX-K ISO 9000 CERTIFIED http: //www.aandd.jp Our revolutionary Super Hybrid Sensor (SHS) tech tec response speed, accuracy and minimizes mainten SHS technology combines the best of magnetic force restoration and single point parallelogram load sensing technologies. Its unique design provides the fastest response speed in its class - just 1.5 seconds! And if the time ever comes when the SHS needs repair, you just replace one of three parts - there is no need to replace the whole sensor! This offers the user Minimum Maintenance Costs. Motor-driven Internal Calibration GX-K The GX-K internal calibration with an internal mass saves time and money. External calibration requires a great deal of skill, time and an expensive external mass. With our internal calibration with internal mass, the balance is calibrated very quickly. ❚ Automatic Self Calibration — Self-calibrates automatically when the balance detects ambient temperature changes. ❚ One Touch Automatic Calibration — Allows you to calibrate the balance on demand with just the push of a button. Just 1.5 Seconds — Ultra Fast Response Speed ❚ Ultra Fast Response Speed – Just 1.5 Seconds.* Ideal for installation with filling machines. * “FAST” setting ❚ Ultra High Performance with minimum maintenance costs. Standard RS-232C Incorporates bi-directional communication with a PC, printer or other peripheral device. Standard Windows Communication Tools Software A free copy of WinCT-A&D's powerful and flexible data collection software tool for virtually instant connection to a PC and a network of other devices. Water and Dust Proof Balances protected from water and dust up to IP65 level. Easy to Clean Water Proof RS-232C Cable (Optional GX-07K) Simple and quick draining structure Water Proof hnology improves chnology nance costs. GX-K GF-K GLP/GMP/GCP/ISO Compliance Smart Range Function (GX/GF-8K2/32K models only) Allows GLP or LIMS balance management by outputting the balance ID number and data used to calibrate the balance. The data can be output to A&D’s AD-8121B printer or a computer, indicating date, time, balance ID number, serial number and calibration data. Accurate, fine weighing is possible even with a heavy container. ID Number ID The balance ID number can be set. It is used to identify the balance when GLP is in use. The ID number is memorized and maintained once it is fixed, even if the AC adapter is removed. Auto Power On Function ON Plug in the unit and it turns itself on without having to press the ON/OFF key. Display Auto Power Off Function OFF Display turns off after 10 minutes of inactivity (can be disabled using function setting) Data Memory Function Memory Format the Data Memory Function for : GX-K • 200 sets of weighing data • 100 sets of weighing data with Time & Date • 50 sets of GLP Data - Time & Date, Calibration Data, ID number and Serial number • 20 sets of Unit Weight for Counting Mode • 20 sets of Upper and Lower Limit Values for Comparator Mode • 20 sets of Tare Value GF-K • 40 sets of weighing data • 50 sets of Unit Weight for Counting Mode • 20 sets of Upper and Lower Limit Values for Comparator Mode • 20 sets of Tare Value Animal Weighing Mode allows you to quickly and accurately determine the weight of any live or unstable subject. Optional animal weighing pan is available. Time & Date (GX-K models only) Standard Time & Date Function complies with GLP and Interval Weighing in the Data Memory Function. Auto Self Checking Automatically checks itself when setting the Automatic Adjustable Environment. Interval Time Setting Weighing intervals of 2, 5, 10, 30 seconds and 1, 2, 5, 10 minutes in the Data Memory Function. Auto Re-Zero Function Re - zeroes automatically after data output. Multiple Weighing Units & Programmable Unit Uses Programmable or standard units of measurement. (g, ct, dwt, etc.) Quick Reference Card A concise, convenient operating guide on the base of the balance. Automatic Adjustable Environment Setting Standard Comparator Function offers increased flexibility and compatibility for a vast number of applications. You can input a target weight and weigh heavier or lighter items using either the keyboard or by placing samples on the pan. Hi, OK or Lo will be indicated on the display to show the comparison results. (GX-04 Comparator out) Adapts to the most suitable Environment Response Setting automatically with one-touch key operation. The response annunciator displays “FAST”, “MID” and “SLOW.” (GX-K ) Manual Response Adjustment can be set by pressing the MODE key and response speed can be adjusted to FAST, MID or SLOW. (GF-K) Automatic Counting Accuracy Improvement (ACAI) is a novel and useful approach to ensuring the utmost in performance when counting even the smallest of items. ACAI automatically updates and refines the average piece weight used to determine the total quantity. Percentage Function facilitates an effective and quick comparison of a sample or commodity against a known reference mass. Simply place an object on the pan to register its weight as 100%. Place another object on the pan to compare its weight in percentage mode. ID Overall Capacity Indication is a unique and helpful feature. By indicating how much of the balance's capacity has been filled, the risk of overloading the balance is minimized. ON OFF Memory GX-K Weighing capacity Minimum weighing value Repeatability (Standard Deviation ) Linearity GX-8K GX-8K2 GX-10K GX-12K GX-20K GX-30K GX-32K 8.1kg 0.01g 0.01g ±0.03g 8.1kg / 2.1kg 0.1g / 0.01g 0.05g / 0.01g ± 0.1g / ±0.02g 10.1kg 0.01g 0.01g ±0.03g 12kg 21kg 0.1g 0.1g ±0.2g 31kg 31kg / 6.1kg 1g / 0.1g 0.5g / 0.1g ±1g / ± 0.2g Stabilization time (on FAST setting) Sensitivity drift (10°C to 30°C, when automatic self calibration is not used) ± 2ppm /°C Operating temperature & humidity range Calibration Display refresh rate Counting mode Minimum unit mass 0.01g Number of samples Percent mode 1g Minimum 100% reference mass Minimum percentage display Transmission Water and dust proof specifications Weighing pan dimensions External dimensions Power supply (AC adapter) Net weight Approximately 1.5 seconds ± 2ppm /°C ±3ppm /°C 5°C to 40°C, below 85%RH (no condensation) Motor-driven Internal Calibration 5 times/second or 10 times a second 0.1g 0.01g 0.1g 10, 25, 50 or 100pieces 10g 1g 10g 0.01%, 0.1%, 1% (depends on reference mass stored) RS-232C (provided as standard, with WinCT, our proprietary data transmission software) Compliant with IP65 270(W) x 210(D) mm (10.62 x 8.26 inch) 300(W) x 355(D) x 111(H) mm (11.81 x 13.97 x 4.37 inch) Confirm that the adapter type is correct for the local voltage and power receptacle Approximately 9.3kg ±3ppm /°C ± 5ppm/°C 1g 100g 1. Even if a heavy tare is used, the measurement can still be made within the fine range. ( Smart range function ) ( GX-8K2 /32K ) 2. We recommend regular calibration and maintenance using an external calibration mass for more accurate linearity. 3. The internal mass is equal to (approximately ) 860 grams. 4. The unit is equipped with an underhook for measuring density and weighing magnetic materials. GF-K Weighing capacity Minimum weighing value Repeatability ( Standard Deviation ) Linearity Stabilization time (on FAST setting) Sensitivity drift ( 10°C to 30°C ) Operating temperature & humidity range Display refresh rate Counting mode Minimum unit mass Number of samples Percent mode Minimum 100% reference mass Minimum percentage display Transmission Water and dust proof specifications Weighing pan dimensions External dimensions Power supply (AC adapter) Net weight GF-8K GF-8K2 GF-10K GF-12K GF-20K GF-30K GF-32K 8.1kg 0.01g 0.01g ±0.03g 8.1kg / 2.1kg 0.1g / 0.01g 0.05g / 0.01g ± 0.1g / ±0.02g 10.1kg 0.01g 0.01g ±0.03g 12kg 21kg 0.1g 0.1g ±0.2g 31kg 31kg / 6.1kg 1g / 0.1g 0.5g / 0.1g ±1g / ± 0.2g ± 2ppm /°C 0.01g 1g Approximately 1.5 seconds ± 2ppm /°C ±3ppm /°C 5°C to 40°C, below 85%RH (no condensation) 5 times/second or 10 times a second 0.1g 0.01g 0.1g 10, 25, 50 or 100pieces 10g 1g 10g 0.01%, 0.1%, 1% (depends on reference mass stored) RS-232C (provided as standard, with WinCT, our proprietary data transmission software) Compliant with IP65 270(W) x 210(D) mm (10.62 x 8.26 inch) 300(W) x 355(D) x 111(H) mm (11.81 x 13.97 x 4.37 inch) Confirm that the adapter type is correct for the local voltage and power receptacle Approximately 8.3kg ±3ppm /°C ± 5ppm/°C 1g 100g 1. Even if a heavy tare is used, the measurement can still be made within the fine range. (Smart range function) (GF-8K2/32K) 2. The unit is equipped with an underhook for measuring density and weighing magnetic materials. Options Physical Dimensions ( mm / inches) AD-8121B AD-8118B AD-8920 AD-8922 AD-1683EX AD-1682 300 / 11.81 270/ 10.63 AD-8121B 111 / 4.37 Dot Matrix Compact Printer Universal Printer Remote Display Remote Controller Static Eliminator Rechargeable Battery Unit (Maximum operating time: 8hours) AX-KO1710-200 RS-232C Cable (25P-9P,2m) AX-SW-128 Foot Switch 237 / 9.33 55/ 2.17 Accessories 63 / 2.48 * 210 / 8.27 * 10 / 0.39 355 / 13.98 345 / 13.58 GX-04K*1 Comparator Output with Buzzer/ RS-232C/current loop output GX-06K*1 Analog output /current loop output GX-07K*2 Waterproof RS-232C cable (5m) GXK-012 Animal weighing pan 1 GX-04K, GX-06K, and the RS-232C (provided as standard) cannot be used at the same time. Water and dust proof specifications cannot be applied when the GX-04K or GX-06K is installed. 2 Use the GX-07K optional water proof RS-232C cable in order to use the standard RS-232C interface for water and dust proof (IP65) capabilities. 250 / 9.84 Specifications subject to change for improvement without notice. ...Clearly a Better Value * GX/GF-K-ADCC-03-PR3-05b05 GX GF Series GX-400 with optional glass breeze break GX-600 with standard breeze break ISO 9000 CERTIFIED http: //www. aandd. jp Our revolutionary Super Hybrid Sensor (SHS) technology improves response speed, accuracy and minimizes maintenance costs. SHS combines the best of magnetic force restoration and single point parallelogram load sensing technologies. Its unique design provides the fastest response speed in its class – just 1 second! And if the time ever comes when the SHS needs repair, you just replace one of three parts – there is no need to replace the whole sensor! This translates to Minimum Maintenance Costs. (An additional benefit of our new SHS is that the GX automatically performs self calibration using the internal mass when the balance detects ambient temperature changes.) Super Hybrid Sensor Motor-driven Internal Calibration ( Patent Pending ) Internal Calibration The GX internal calibration with an internal mass saves time and money. External calibration requires a great deal of skill, time and an expensive external mass. With our internal calibration with internal mass, the balance is calibrated very quickly. ❚ Automatic Self Calibration — Self-calibrates automatically when the balance detects ambient temperature changes. ❚ One Touch Automatic Calibration — Allows you to calibrate the balance on demand with just the push of a button. ❚ Calibration is essential for accuracy in weighing. For example, in high resolution balances, changes in sensitivity drift can be caused by changes in the ambient temperature. Take the GX 600 for example, the weight might change by ±0.010g with a change of 10°C. (Sample’s weight: 500g) ❚ The GX’s internal calibration mass is adjusted to an “OIML F1 class level.” by the standard balance calibrated with an “OIML E2 class level mass”. (The GX’s internal calibration mass is not “the standard mass for legal metrology” nor “OIML’s level of calibration mass.” Instead it is the mass for adjustment.) Just 1 Second — Ultra Fast Response Speed ❚ Ultra Fast Response Speed–Just 1 Second.* Ideal for installation with filling machines. * “FAST” setting ❚ Ultra High Performance with minimum maintenance costs. Standard RS-232C Incorporates bi-directional communication with a PC, printer or other peripheral device. Standard Windows Communication Tools Software WinCT A free copy of WinCT-A&D's powerful and flexible data collection software tool for virtually instant connection to a PC and a network of other devices. GX GF OFF VFD Display Bright, bold, blue vacuum fluorescent display ( VFD ) that is virtually unmistakable from any viewing angle. Animal Weighing Mode allows you to quickly and accurately determine the weight of any live or unstable subject. Optional animal weighing pan (GX-12) is available. Automatic Adjustable Environment Setting Standard Comparator Function Manual Response Adjustment can be set by pressing the MODE key and response speed can be adjusted to FAST, MID or SLOW. offers increased flexibility and compatibility for a vast number of applications. You can input a target weight and weigh heavier or lighter items using either the keyboard or by placing samples on the pan. Hi, OK or Lo will be indicated on the display to show the comparison results. (GX-04 Comparator output ) Percentage Overall Capacity Indication Adapts to the most suitable Environment Response Setting automatically with one-touch key operation. The response annunciator displays “FAST”, “MID” and “SLOW.” (GX) Automatic Counting Accuracy Improvement (ACAI) is a novel and useful approach to ensuring the utmost in performance when counting even the smallest of items. ACAI automatically updates and refines the average piece weight used to determine the total quantity. Function facilitates an effective and quick comparison of a sample or commodity against a known reference mass. Simply place an object on the pan to register its weight as 100%. Place another object on the pan to compare its weight in percentage mode. Main Features SHS (Super Hybrid Sensor) Internal Calibration VFD Display WinCT Data Memory Function Automatic Adjustable Environment Setting Auto Self Checking Density Determination Function Quick Reference Card Underhook Time & Date Function Large Square Weighing Pan Comparator Function Animal Weighing Capacity Indicator ACAI Counting Function Percentage Function Front Air Bubble Leveling Standard RS-232C GLP, GMP, GCP, ISO Compliance Data Output Splash Proof Keyboard and Display Display Auto Power Off Function Aluminum Die-Cast Case GX series ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ is a unique and helpful feature. By indicating how much of the balance's capacity has been filled, the risk of overloading the balance is minimized. GF series ✔ —— ✔ ✔ ✔ ( Manual ) ✔ ✔ ✔ ✔ —— ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Splash Proof Keyboard and Display Auto Self Checking Balances protected from dust and spills Automatically checks itself when setting the Automatic Adjustable Environment GLP/GMP/GCP/ISO Compliance Allows GLP or LIMS balance management by outputting the Balance ID number and data used to calibrate the balance. The data can be output to A&D’s AD–8121B printer or a computer, indicating date, time, Balance ID number, serial number and calibration data. Standard Underhook Ideal for density determination and weighing magnetic substances. Density Measurement Function Picture shown with GX-13 Density Measurement Kit Standard RS-232C Interval Time Setting Bi-directional communication with a PC or connects directly to a printer Weighing intervals of 2, 5, 10, 30 seconds and 1, 2, 5, 10 minutes in the Data Memory Function Commands Auto Power On Function A PC can control the balance by sending commands to the balance. • Commands to query weighing data • Commands to control the balance • Commands to control the memory function • Commands to control the comparator function Plug it in and it turns itself on without pressing ON/OFF key STANDARD ID Number The balance ID number can be set. It is used to identify the balance when GLP is used. The ID number is memorized and maintained once it is fixed, even if the AC adapter is removed. OFF Display Auto Power Off Function Display turns off after 10 minutes of inactivity ( can be disabled when undesired ) Data Memory Function ( Patent Pending ) Format the Data Memory Function for: GX • 200 sets of weighing data • 100 sets of weighing data with Time & Date • 50 sets of GLP Data–Time & Date, Calibration Data, ID number and Serial number • 20 sets of Unit Weight for Counting Mode GF • 40 sets of weighing data • 20 sets of Unit Weight for Counting Mode Time & Date (GX only) Standard Time & Date Function complies with GLP and Interval Weighing in the Data Memory Function Auto Re-Zero Function Re-Zeroes automatically after data output Large Square Weighing Pan Standard large square weighing pan on all models 128 x 128mm for 0.001g resolution models 165 x 165 mm for 0.01g and 0.1g resolution models Multiple Weighing Units & Programmable Unit Uses Programmable or standard units of measure ( g, ct, dwt etc.) Front Air Bubble Leveling Easily check the balance’s level from the front Quick Reference Card A fast, convenient operating guide installed at the bottom of the balance Specifications Weighing capacity GX-200 GX-400 GX-600 GX-800 GX-1000 GX-2000 GX-4000 GX-6100 GX-6000 GX-8000 GF-200 GF-300 GF-400 GF-600 GF-800 GF-1000 GF-1200 GF-2000 GF-3000 GF-4000 GF-6100 GF-6000 GF-8000 210g 310g 410g Stabilization time (typical at FAST) 810g 1100g 1210g 2100g 3100g ±0.003g Approx. 1second Approx. 1.5 seconds 0.1g ± 0.02g Approx. 1second ±0.03g ± 0.1g Approx. 1.5seconds Approx. 1second ± 5ppm/°C (auto-self calibration OFF) Super Hybrid Sensor (SHS) *SHS: Patent issued and pending Display type Vacuum Fluorescent Display (VFD) Display refresh rate 5times/second or 10times/second 0.001g Counting Minimum unit mass mode Number of samples 0.01g 0.1g 1.00g 10.0g 10, 25, 50 or 100pieces 0.100g Minimum 100% reference mass 0.01%, 0.1%, 1% (Depends on reference mass stored) Minimum 100% display RS-232C Interface with Windows Communication Tools ( WinCT: included as CD-ROM) Standard serial I/F 128 x 128mm (5.04 x 5.04 inch) 165 x 165 mm (6.50 x 6.50 inch) Motor-driven Internal Calibration (GX only) Calibration 210(W) x 317(D) x 86(H)mm (8.27 x 12.48 x 3.39inch) External dimensions Confirm that the adapter type is correct for the local voltage and power receptacle Approx. 11VA (supplied by AC adapter) Power consumption Net weight 8100g 5°C to 40°C (41°F to 104°F), 85%RH or less (No condensation) Sensing method AC adapter 6100g 0.1g ±2ppm/oC (When automatic self calibration is not used) Operating temperature Weighing pan 6100g 0.01g ± 0.002g Sensitivity drift (10°C to 30°C/50°F-80°F) Percent mode 4100g 0.01g 0.001g Repeatability (Standard Deviation) Linearity 610g 0.001g Minimum weighing value Approx. 4.6kg(GX)/3.8kg (GF) Approx. 5.1kg (GX) / 4.3kg (GF) Notes: The internal mass is equal to (approximately) 500grams. EC Type Approval Confirmed (Approval No. UK2560) Standard Breeze break included for 1mg Minimum weighing value models Dimensions With Optional Glass Breeze Break (mm) 454.3 317 210 163 244 A GX-04* Comparator Output with a Buzzer/ RS-232C/Current Loop Output GX-06* Analog Output /Current Loop Output GX-10 Glass Breeze Break for 128 x 128mm weighing pan size models GX-11 Glass Breeze Break for 165 x 165mm weighing pan size models GX-12 Animal weighing pan (not applicable for GX-200 and GF-200) GX-13 Density Determination Kit for 128 x 128mm weighing pan size models 04& 06 cannot co-exist Factory installed option 28 Physical Dimensions (mm) 317 Options 162.5 45 * * 210 Accessories 231.3 141 195.5 176 207.5 Pan size (mm) Model GX-200/400/600/800/1000 GF-200/300/400/600/800/1000 A B 162.5 128 128 GX-2000/4000/6100/6000/8000 GF-1200/2000/3000/4000/6100/6000/8000 165 165 86 Dot Matrix Compact Printer Universal Printer Remote Display Remote Controller Rechargeable Battery Unit (Maximum operating time: 8hours) AD-1683EX Static Eliminator AX-KO1710-200 RS-232C Cable (25P-9P) AX-SW-128 Foot Switch AX-073003691-S Dust cover for 128 x 128mm weighing pan size models AX-073003692-S Dust cover for 165 x 165mm weighing pan size models 86 B AD-8121B AD-8118B AD-8920 AD-8922 AD-1682 Approx. 1 second Specifications subject to change for improvement without notice. ...Clearly a Better Value * GX/GF-ADCC-05-PR5-05c05 FX-i FX-iWP Series ISO 9000 CERTIFIED ...Clearly a Better Value http://www.aandd.jp Realizing Compact, Increasing Functions! We have developed a Miniaturized SHS* (Super Hybrid Sensor) to achieve a highly compact precision balance, which is 40% lighter and 47% smaller than our GF series with a 25% smaller footprint, while maintaining A&D’s superior weighing functions. * Patent Pending FX-120i FX-200i FX-300i FX-1200i FX-2000i FX-3000i 122gx1mg 220gx1mg 320gx1mg 1220gx10mg 2200gx10mg 3200gx10mg FX-i Response Indicator Function Comparator Function Selectable FAST, MID or SLOW response to suit weighing environment conditions Easy to compare weighing results by setting HI limit and LO limit to display HI,OK,LO indicator ACAI – Automatic Counting Accuracy Improvement Percent Mode Function This counting function recalculates the average unit weight each time a sample is added to eliminate errors caused by variations in unit weight A sample can be registered as 100% and the weight of another sample can be compared as a percentage B5 Size Footprint Ideal for installation and use in narrow spaces Compact SHS–1 Second Stabilization Quick stabilization speed with accurate weighing for better productivity Shock Absorber Function* The internal shock absorber protects the SHS from the adverse effects of vertical or transverse overloading. * Patent Pending Quick USB Interface (FXi-02) Easy-to-use optional USB interface, with no driver installation necessary, for transfer of weighing data to a computer (applicable OS – Windows 98 OSR2 or later) SCF–Statistical Calculation Function Can display and/or output statistical calculation data as No. (number of data), SUM (total), MAX (maximum), MIN (minimum), R [range (maximum – minimum)], AVE (average), SD (standard deviation) and CV (coefficient of variation) LAN–Ethernet Interface (FXi-08) with WinCT-Plus Software WinCT-Plus software makes it possible for the user to easily set up an IP address, subnet mask etc. The user can also send commands for control and acquisition of data from multiple FX-i balances. Ethernet Hub Provided by end-user WinCT-Plus Note : Ethernet Hub and cables must be provided by end-users Animal Weighing Function Standard RS-232C Interface The HOLD function enables freezing of weighing data for animal weighing applications and an ANIMAL indicator appears on the display Incorporates bi-directional communication with a PC, printer or other peripheral devices Underhook Multiple Weighing Units of Measurement The underhook, for hanging applications, allows for measurement of magnetic materials and density measurements in air and water Programmable or standard weighing units of measurement can be selected; g, pcs, %, oz, lb, L oz, ozt, ct, mom, dwt, GN, tl, tol, mes and MLT The World’s First IP65 Compliant, Water / Dust Proof Precision (1mg) Balance! Yet another breakthrough from A&D enabling the measurement of liquid or powder at 1mg resolution, eliminating any worries about damage to the balance FX-120iWP FX-200iWP FX-300iWP 122gx1mg 220gx1mg 320gx1mg FX-1200iWP FX-2000iWP 1220gx10mg 2200gx10mg FX-3000iWP 3200gx10mg FX-iWP GLP/GMP/GCP/ISO Compliant Auto Power ON Function In accordance with GLP and LIMS regulations, the balance ID number and calibration data can be printed out using A&D’s AD-8121B or a PC The weighing mode display activates automatically with AC power so there is no need to press the ON/OFF key Auto Power OFF Function Built-in Rechargeable Battery (FXi-09)* The display switches OFF automatically when the balance is inactive for 10 minutes as a power-saving tool An optional Ni-MH rechargeable battery pack can be fitted into the FX-i series for use without AC power and for mobile applications (10 hours charging time for 8 hours operation) * Not IP65 compliant when used with FX-iWP IP65 means that this kind of measurement is possible. Highly Visible Display Firmly Sealed Pan Support Large Breeze Break (optional) Water Proof RS-232C Cable (optional) The small breeze break comes as standard with the FX-120i(WP), FX-200i(WP) and FX-300i(WP), which are all 1mg resolution models. Specifications FX-120i FX-120iWP 122g Weighing capacity FX-200i FX-200iWP FX-300i FX-300iWP 220g 320g Minimum weighing value 0.001g Counting mode 0.001g Minimum unit mass 1220g 2200g 3200g 0.01g 0.01g 5, 10, 25, 50 or 100 pieces Number of samples Percent mode FX-1200i FX-2000i FX-3000i FX-1200iWP FX-2000iWP FX-3000iWP 0.001g Minimum 100% reference mass 1.00g 0.01%, 0.1%, 1% (depends on the reference mass stored) Minimum 100% display Repeatability (Standard Deviation) Linearity 0.001g 0.01g ±0.002g ±0.02g Approx. 1 second Stabilization time (typically set at FAST) ±2ppm /°C Sensitivity drift (10°C to 30°C) 5°C to 40°C (41°F to 104°F), 85%RH or less (no condensation) Operating temperature Vacuum Fluorescent Display (VFD) Display type 5 times /second, 10 times /second or 20 times /second Display refresh rate RS-232C Interface Standard serial interface 130mm Weighing pan (diameter) External calibration mass 150mm 100g 200g 300g 1000g 2000g 3000g 50g 100g 200g 500g 1000g 2000g 100g Approx. 11VA (supplied to the AC adaptor) Power consumption 193 (W) X 262.5 (D) X 85.5 (H) mm External dimensions FX-i Approx. 2.5kg / FX-i WP Approx. 2.7kg Net weight * 193 / 7.6 External Dimensions (mm/inches) Pan size A A 130 / 5.12 150 / 5.91 262.5 / 10.33 Model FX-120i (WP) / 200i (WP) / 300i (WP) FX-1200i (WP) / 2000i (WP) / 3000i (WP) 168.5 / 6.63 70.5 / 2.78 Quick USB interface with cable Ethernet interface with WinCT-Plus software Built-in rechargeable battery Small breeze break Large breeze break Small breeze break (gray) Large breeze break (gray) Animal weighing pan Carrying case 85.5 / 3.37 Options FXi-02* FXi-08* FXi-09* FXi-10 FXi-11 FXi-WP-10 FXi-WP-11 FXi-12 FXi-15 1000g Confirm that the adaptor type is correct for the local voltage and power receptacle AC adaptor 162 / 6.38 61.5 / 2.42 194.5 / 7.66 192* 3* *Underhook FXi-02, FXi-08 and FXi-09 cannot be used at the same time. (Not IP65 compliant when used with FX-iWP) Dimensions with Small Breeze Break (FX i-10/FX i-WP-10) 193 / 7.6 (Comes equipped with FX-120i (WP)/200i (WP)/300i (WP)) 184 / 7.24 168.5 / 6.63 * (Not IP65 compliant when used with FX-i WP) ø130 / 5.12 115 / 4.53 171.5 / 6.75 175 / 6.89 Static eliminator Remote display Remote controller Compact printer RS/Ethernet converter Carat pan Waterproof RS-232C cable (5m) 81 / 3.19 83.5 / 3.29 115 / 4.53 85.5 / 3.33 85 / 3.35 AD-1683 AD-8920* AD-8922* AD-8121B* AD-8526* AX-CARATPAN AX-KO2737-500-EX 184 / 7.24 262.5 / 10.33 Accessories Dimensions with Large Breeze Break (FX i-11/FX i-WP-11) 105/4.13 112/4.41 AD-8121B Ø156/6.14 294/11.57 294/11.57 199.5/7.85 193/7.6 107/4.21 ...Clearly a Better Value Vereyskaya str.112 Kuntsevo Block, 121357, Moscow, Russia *FXi/WP-ADCC-01-PR1-07905 Precision Balances FZ FZ-i FX FX-i Series ISO 9000 CERTIFIED ...Clearly a Better Value http://www.aandd.jp “High Functionality You Can Afford” The FZ-i/FX-i Series, a new addition to A&D’s precision balances, rivals our GX/GF Series in performance and quality, but offers higher accessibility, bringing to you a cost-effective solution for a diverse array of applications. Newly developed, Air-pump Controlled Internal Calibration*(FZ-i models only)* Patent Pending For the internal calibration of the FZ-i Series, A&D adopted a direct-driving method that utilizes air pressure for its power source. This new method features a simple structure, high reliability and a fail-safe mechanism – the internal mass returns to the original position even if the calibration is interrupted by power failure, etc. One Touch Automatic Calibration (FZ-i models only) With just one press of a key, you can ensure the accuracy of your balance. Compact, B5 Size Footprint By taking advantage of our Compact Super Hybrid Sensor (C-SHS) technology*, A&D has significantly reduced the size of the FZ-i/FX-i Series – 25% smaller footprint than the GX/GF Series, making it ideal for installation and use in narrow spaces. *Patent Pending Fast, 1 Second Stabilization The C-SHS combines the best of magnetic force restoration and single point parallelogram load sensing technologies. This allows the C-SHS to realize a response speed of just 1 second while maintaining extremely high span stability. The FZ-i/FX-i Series will maximize your productivity and efficiency. Shock Absorber Function* *Patent Pending The internal shock absorber protects the C-SHS from the adverse effects of vertical and transverse overloading. Super Hybrid Sensor VFD Display Quick USB LAN-Ethernet Interface RS-232C Interface GLP Compliant Counting Function Percentage Function Auto Power OFF Underhook Rechargeable Battery Software Internal Calibration External Calibration (FZ-i) (FX-i) ON Comparator Function Auto Power ON Animal Weighing Statistical Calculation LAN-Ethernet Interface (FXi-08) with WinCT-Plus Software WinCT-Plus software makes it possible for the user to easily set up an IP address, subnet mask, etc. The user can also send commands for control and acquisition of data from multiple balances. Ethernet Hub Provided by end-user WinCT-Plus Note : Ethernet Hub and cables must be provided by end-users Quick USB Interface (FXi-02) Easy-to-use optional USB interface, with no driver installation necessary, for transfer of weighing data to a computer (applicable OS – Windows 98 OSR2 or later) Standard RS-232C Interface Incorporates bi-directional communication with a PC, printer or other peripheral devices. Multiple Weighing Units Programmable or standard weighing units of measurement can be selected; g, pcs, %, oz, lb, L oz, ozt, ct, mom, dwt, GN, tl, tol, mes and MLT GLP/GMP/GCP/ISO Compliant In accordance with GLP and LIMS regulations, the balance ID number and calibration data can be printed out using A&D’s AD-8121B or a PC Statistical Calculation Function Can display and/or output statistical calculation data as No. (number of data), SUM (total), MAX (maximum), MIN (minimum), R [range (maximum – minimum)], AVE (average), SD (standard deviation) and CV (coefficient of variation) Response Indicator Function Selectable FAST, MID or SLOW response to suit weighing environment conditions. ACAI – Automatic Counting Accuracy Improvement This counting function recalculates the average unit weight each time a sample is added to eliminate errors caused by variations in unit weight Built-in Rechargeable Battery (FXi-09) An optional Ni-MH rechargeable battery pack can be fitted into the FZ-i/FX-i Series for use without AC power and for mobile applications (10 hours charging time for 8 hours operation) Large Breeze Break (FXi-11) The small breeze break comes as standard with all the FZ-i models, FX-120i, FX-200i and FX-300i. Carat Balance Specifications FZ-120i FX-120i 122g Weighing capacity FZ-200i FX-200i FZ-300i FX-300i FZ-1200i FX-1200i FZ-2000i FX-2000i FZ-3000i FX-3000i 220g 320g 1220g 2200g 3200g Minimum weighing value 0.001g Counting mode 0.001g Minimum unit mass 0.01g 0.01g 5, 10, 25, 50 or 100 pieces Number of samples Percent mode 0.100g Minimum 100% reference mass 1.00g 0.01%, 0.1%, 1% (depends on the reference mass stored) Minimum 100% display Repeatability (Standard Deviation) Linearity 0.001g 0.01g ±0.002g ±0.02g Approx. 1 second Stabilization time (typically set at FAST) ±2ppm /°C Sensitivity drift (10°C to 30°C) 5°C to 40°C (41°F to 104°F), 85%RH or less (no condensation) Operating temperature Vacuum Fluorescent Display (VFD) Display type 5 times /second, 10 times /second or 20 times /second Display refresh rate RS-232C Interface Standard serial interface 130mm Weighing pan (diameter) External calibration mass 150mm 100g 200g 300g 1000g 2000g 3000g 50g 100g 200g 500g 1000g 2000g 100g Approx. 11VA (supplied to the AC adaptor) Power consumption 193 (W) X 262.5 (D) X 85.5 (H) mm External dimensions FZ-i Approx. 3.0kg / FX-i Approx. 2.5kg Net weight A 262.5 / 10.33 A 130 / 5.12 150 / 5.91 Model FZ,FX-120i / 200i / 300i FZ,FX-1200i / 2000i / 3000i 168.5 / 6.63 162 / 6.38 61.5 / 2.42 194.5 / 7.66 192* 3* *Underhook Accessories Dimensions with Small Breeze Break (FX i-10) 193 / 7.6 (Comes equipped with FZ,FX-120i /200i /300i , FZ-1200i /2000i /3000i ) 184 / 7.24 184 / 7.24 168.5 / 6.63 115 / 4.53 171.5 / 6.75 175 / 6.89 ø130 / 5.12 81 / 3.19 83.5 / 3.29 115 / 4.53 85.5 / 3.33 85 / 3.35 Static eliminator Electrostatic fieldmeter Tweezers for calibration weight Remote display Remote controller Compact printer Universal printer RS-232C cable (9P-9P) Serial/Ethernet converter Serial/USB converter Carat pan (silver, 2pcs) Carat pan (black, 2pcs) Main unit cover (5pcs) 262.5 / 10.33 * FXi-02, FXi-08 and FXi-09 cannot be used at the same time. Pan size 70.5 / 2.78 Quick USB interface with cable Ethernet interface with WinCT-Plus software Built-in rechargeable battery Small breeze break Large breeze break Animal weighing pan (FZ,FX-1200i / 2000i / 3000i ) Carrying case AD-1683 AD-1684 AD-1689 AD-8920A AD-8922 AD-8121B AD-8118C AX-KO2466-200 AD-8526 AX-USB-9P AX-CARATPAN-W AX-CARATPAN-B AX-FXi-31 193 / 7.6 External Dimensions (mm/inches) 85.5 / 3.37 Options FXi-02* FXi-08* FXi-09* FXi-10 FXi-11 FXi-12 FXi-15 1000g Confirm that the adaptor type is correct for the local voltage and power receptacle AC adaptor Dimensions with Large Breeze Break (FX i-11) 105/4.13 AD-8121B 112/4.41 294/11.57 315/12.4 199.5/7.85 193/7.6 Ø156/6.14 107/4.21 ...Clearly a Better Value Vereyskaya str.112 Kuntsevo Block, 121357, Moscow, RUSSIA *FZi/FXi-ADCC-01-PR1-08c05 GP Series A new contender in the industrial balance field http://www.aandd.jp The World’s Most The GP Series incorporates our enhanced weighing sensor, Double Leveraged Super Hybrid Sensor ( SHS). Building on the basic SHS features of fast and stabilization, our enhanced SHS technology brings the most accurate weighing results to the industrial balances in 12kg to 101kg capacities class. Internal Calibration The GP internal calibration with an internal mass saves time and money. External calibration requires a great deal of skill, time and an expensive external mass. With our internal calibration with internal mass, the balance is calibrated very quickly. ■ Automatic Self Calibration — Self-calibrates automatically when the balance detects ambient temperature changes ■ One Touch Automatic Calibration — Allows you to calibrate the balance on demand with just the push of a button. ■ Calibration is essential for accuracy in weighing. For example, in high resolution balances, changes in sensitivity drift can be caused by changes in the ambient temperature. Take the GP-30K for example, the weight might change by 0.9g with a change of 10˚C. ( Sample’s weight: 30kg ) ■ Thanks to our Double Leveraged Super Hybrid Sensor, the GP's motor-driven internal calibration mass is equivalent to a 50kg calibration mass in terms of top loading capacity on the weighing pan. The adjusted weighing accuracy is within + –15 digits in relation to the weighing capacity while conforming to the OIML's Class II balances definitions after using GP's internal calibration mass. Standard WinCT WinCT (Windows Communication Tools Software), provides easy transmission of weighing data from A&D balances to a computer using the RS-232C interface. Quickly exports data into Windows applications in a manageable format limited only by the computer’s capabilities. RS-232C Interface Using a USB/ RS-232C Converter, you can transfer data between a USB equipped PC and a GP balance. This also makes your GP balance hot-swappable-no need to turn the balance and computer off before disconnecting the balance. t User-Friendly Indus GP-S with detached display unit GP-30KS GP-100KS (31kg/0.1g ) (101kg/1g ) GP Series Super Hybrid Sensor with Swing Arm display type Vacuum Fluorescent Full Digital Calibration GP-12K GP-20K GP-32K GP-30K GP-40K GP-60K GP-100K GP-102K Complies with GLP/GMP format RS-232C Serial Interface IP-65 resistant to water & dust HI/OK/LO Comparator Automatic Counting Accuracy Improvement Windows Communication Tools Software Display Auto Power OFF Internal Calibration Detachable Display Unit (12kg/0.1g ) (21kg/0.1g ) (6.1kg/0.1g * · 31kg/1g ) (31kg/0.1g ) (41kg/0.5g ) (61kg/1g ) (101kg/1g ) (61kg/1g * · 101kg/10g ) SmartRange * The GP-32K and GP-102K have the precision and standard ranges. The precision range has a higher resolution and the standard one is normal resolution. Pressing the RE-ZERO key allows weighing in the precision range, regardless to the tare value. ( SmartRange function). SmartRange function enables you to weigh or add samples in the precision range without removing container and/or those objects that have been placed on the pan. strial Balances… Swing Arm Display Compliant IP-65 ( resistant to dust, water and moisture) Clear & Large VFD Display Easy to see - even in the dark / Wide angle view prevents mistakes Animal Weighing Mode allows you to quickly and accurately determine the weight of any live or unstable subject. Optional animal weighing pan (GP12) is available. Automatic Adjustable Environment Setting Adapts to the most suitable Environment Response Setting automatically with one-touch key operation. The response annunciator displays “FAST”, “MID” and “SLOW.” Manual Response Adjustment can be set by pressing the MODE key and response speed can be adjusted to FAST, MID or SLOW. Automatic Counting Accuracy Improvement (ACAI) is a novel and useful approach to ensuring the utmost in performance when counting even the smallest of items. ACAI automatically updates and refines the average piece weight used to determine the total quantity. Percentage Function facilitates an effective and quick comparison of a sample or commodity against a known reference mass. Simply place an object on the pan to register its weight as 100%. Place another object on the pan to compare its weight in percentage mode. Standard Comparator Function offers increased flexibility and compatibility for a vast number of applications. You can input a target weight and weigh heavier or lighter items using either the keyboard or by placing samples on the pan. Hi, OK or Lo will be indicated on the display to show the comparison results. Overall Capacity Indication is a unique and helpful feature. By indicating how much of the balance's capacity has been filled, the risk of overloading the balance is minimized. IP-65 Splash Proof Keyboard, Display and Base Units Balances protected from dust and spills up to IP65 level GLP/GMP/ISO Compliance Allows GLP, GMP and ISO balance management by outputting the Balance ID number and data used to calibrate the balance. The data can be output to A&D’s AD-8121B printer or a PC, indicating date, time, Balance ID number, serial number and calibration data. Data Memory Format the data memory function for: • 200 sets of weighing data • 100 sets of weighing data with Time & Date • 20 sets of Tare values • 50 sets of GLP data-Time & Date, Calibration Data, ID Number and Serial number • 50 sets of Unit Weight for Counting mode • 20 sets of comparator Upper & Lower Limits Time & Date Standard Time & Date Function complies with GLP and Interval Weighing in the Data Memory function. Auto Self Checking Standard RS-232C Bi-directional communication with a PC or connect directly to a printer Automatically checks itself when setting the Automatic Adjustment Environment. Interval Time Setting Commands Weighing intervals of 2, 5, 10, 30 seconds and 1, 2, 5, 10 minutes in the Data Memory Function. A PC can control the balance by sending commands to the balance. • Command to query weighing data • Command to control the balance • Command to control the memory function • Command to control the comparator function Auto Re-Zero ID Number The balance ID number can be set. It is used to identify the balance when GLP is used. The ID number is memorized and maintained once it is fixed, even if the AC adaptor is removed. Re-Zeros automatically after data output Large Stainless Steel Weighing Pan 384mm x 344mm for GP-12K/20K/32K/30K/30KS/40K/60K 386mm x 346mm for GP-100K/100KS/102K Multiple Weighing Units & Programmable Unit Optional Underhook Uses programmable or standard units of measure ( g, kg, lb, OZ, c t, dwt, OZt, mom, TL, MS, tola and DS ) Ideal for density determination and weighing magnetic substances • GP-20 Underhook for GP-12K/20K/32K/30K/40K/30KS • GP-21 Underhook for GP-60K/100K/102K/100KS Air Bubble Leveling Easily check the balance for level installation Density Determination of a Solid Object SmartRange The GP has a density determination mode, which is available after changing the internal parameter settings. Once the object’s weight in the air, in liquid and the liquid density are input, the solid density will be calculated. It is useful to determine concrete's density. For more accurate weighing, SmartRange function is provided on the GP32K (6.1kg x 0.1g/31kg x 1g) and GP-102K (61kg x 1g/101kg x 10g). Enlargement Indication of HI, OK, LO Symbols With MODE key pressed during usual HI, OK or LO indication, the display is refreshed from 3.0000kg HI to HI kg . The letters (HI, for example ), can be enlarged. Built-In Internal Calibration Mass The GP has a built-in internal calibration mass. Internal calibration mass is equivalent to a 50kg calibration mass in terms of top loading capacity on the weighing pan. Display Auto Power OFF Display turns off after 10 minutes of inactivity, which can be disabled when not needed. Accumulation of Weighing Results Auto Power ON GP can accumulate the weighing results and display and output them. Plug it in and it turns ON without pressing the ON/OFF key. Specifications GP-12K GP-20K GP-32K GP-30K GP-30KS GP-40K GP-60K 31kg 31kg 41kg 61kg 1g/0.1g (Smart Range) 0.1g 0.5g 0.5g Models 12kg Weighing Capacity 21kg 0.1g Resolution Repeatability (Standard Deviation) Linearity 0.1g 0.5g/0.1g 0.1g ±0.2g ±1g/±0.2g ±0.2g Accuracy just calibrated by internal mass ±3ppm/˚C Sensitivity Drift (10˚C-30˚C /50˚F-86˚F) ±1.0g ±5ppm/˚C ±3ppm/˚C 101kg 10g/1g (Smart Range) 1g 5g/1g ±2g ±10g/±2g 0.7g ±1g ±1.5g ±5g ±5ppm/˚C ±6ppm/˚C ±10g ±10ppm/˚C Super Hybrid Sensor (SHS) Sensing Method Vacuum Fluorescent Display (VFD) Display Type 5 times/second or 10 times/second Display Refresh Rates Percent Mode 101kg 1g 5˚C to 40˚C ( 41˚F to 104˚F ), 85% RH or less ( No condensation ) Operating Temperature Counting Mode GP-102K 1.5 seconds (TYP at FAST mode) Stabilization Time Weighing Units and Modes GP-100K GP-100KS g, kg, lb, L OZ, OZ, ct, dwt, OZt, mom, TL, MS, tola, DS and % and counting PCS [ Weighing units g, ct, and dwt are not available on GP-102K ] 0.1g Minimum unit mass 1g 0.1g 0.5g 1g 10g 100g 1000g 10, 25, 50 or 100 pieces Number of samples 10g Min. 100% reference mass 100g 10g 50g 0.01%, 0.1%, 1% (automatically switches depening on the reference mass stored) Min. 100% display RS-232C Serial Interface with Windows Communication Tools (WinCT) Standard Interface Recommended External Calibrating Weight 5kg 10kg 20kg 20kg 20kg 30kg 10kg 20kg 30kg 30kg 30kg 40kg 80kg 40kg 50kg 100kg 60kg 60kg Complies with IP-65 (International Protect), covers the entire apparatus Water & Dustproof Level Weighing Pan Stainless steel weighing pan (Wash down type) 386mm x 346mm 384mm x 344mm Motor-driven internal calibration mass with SHS Calibration External Dimensions 372(W)x615(D)x130(H)mm 373(W)x615(D)x130(H)mm (Note: GP-30KS is 344(W)x442(D)x130(H)mm) (Note: GP-100KS is 346(W)x443(D)x130(H)mm) Please confirm that the adapter is correct for the local voltage and power receptacle. AC Adaptor Approximately 14VA (supplied by AC adaptor) Power Consumption Approximately 17kg Net Weight Options Approximately 18kg Dimensions (mm) GP-04: Comparator Output (Relay with Buzzer) / RS-232C / Current Loop GP-06: Analog/Current Loop Output GP-07: 5-meter connection cable(factory option) (For GP-30KS & GP-100KS) GP-12: Animal weighing pan GP-20: Underhook (For GP-12K/20K/32K/30K/30KS and GP-40K) GP-21: Underhook (For GP-60K/100K/100KS and GP-102K) GP-22: AD-8121B Printer Support Accessories AX-KO1710-200: RS-232C cable (25P-9P) AX-SW-128: Foot Switch Swing Arm-Display type Peripherals (sold separately) AD-1682: Rechargeable Battery Unit AD-8920: Remote Display AD-8121B: Dot Matrix Compact Printer AD-8118B: Universal Printer AD-8922: Remote Controller Detached Display type GP-30KS/GP-100KS AD-1682: Rechargeable Battery Unit Specifications subject to change for improvement without notice. ...Clearly a Better Value * GP-ADCC-06-PR4-05c025