Download Country Flame HR-01 Operating instructions
Transcript
manufacturers for the latest specifications and the cost of mobile home chimney system parts or a mobile home chimney kit. TABLE 4: MOBILE HOME (minimum) VENT SYSTEM REQUIRED PARTS PART NUMBER 4PRC 4PF 4P36 4PRS 4P60 4PT3 CERAFORM 126 3PSAU 4PSC DESCRIPTION VERTICAL CHIMNEY CAP 4” OVER TEN FEET STANDARD ROOF FLASHING THREE FOOT VENT PIPE, 4” ROOF SUPPORT FIVE FOOT VENT PIPE, 4” 3” TO 4” CLEAN OUT “T” WALL PROTECTION ( IF REQUIRED) UNVERSAL STOVE ADPATER STORM COLLAR QTY 1 1 1 1 1 1 1 1 1 NOTE: The information provided in TABLE 4 and detailed in FIGURE 18 are for EXAMPLE only. Vent systems are affected by local site conditions and local codes. Consult a certified professional and insure that any mobile home Harvester vent system installation meets all federal, state, and local building codes. Failure to follow the chimney manufacturer’s installation instructions will void Country Flame’s product warranty. Failure to utilize a certified installation will void the warrant and may have an adverse impact on the homeowner’s insurance policy. One of the major causes of mobile home fires is improperly installed and operated heating systems. Contact Country Flame or one of its local authorized dealers to resolve any questions about installation or parts usage. Version 6.0d 36