Troubleshooting LSI New Provider Eagle 2
Q: What is the default username/password?
A: admin/admin
Q: What is the default namespace?
A: /root/lsiarray13
Q: Where are the log files located?
A: To enable logging, do the following:
Note: Changes to the tracing level requires a restart of the provider to take
effect.
1.
Go to the directory where SMI-S Provider is stored.
a. For a Windows operating system, the directory is C:\LSI\.
b. For a UNIX-based operating system, the directory is /opt/lsi/sbma/data/.
2.
Edit the providerTraceLog.properties file.
a. Remove the pound sign (#) from the lines containing FILE, LEVEL, and
EVENTS.
3. Save the file, and exit the text editor.
4. Stop and start the CIM server by using the specific location and name.
Q: How do I change the ports that the provider binds to?
A: Go to the <installPath>\bin directory.
For a Windows operating system, the directory is c:\lsi\pegasus28\pegasus\bin
For a UNIX-based operating system, the directory is
/opt/pegasus28/pegasus/bin/
Run the following commands:
cimconfig –s httpPort=<newHttpPort> -p
cimconfig –s httpsPort=<newHttpsPort> -p
Q: I keep getting a “Storage array added successfully”, but instead of
returning the UUID, it returns a “index string out of bounds”.
A: Double check the IP address. This is the provider’s way of saying, “this host
is pingable, but it’s not a storage array”.
Q: Array does not appear to be added to the provider when editing the
arrayhosts.txt file, what should I do?