Troubleshooting Electronic Control Tumbler Troubleshooting Guide JTD30XG-EC, JTB30XG-EC, STB30XG-3C, JTD32DG-EC, STD32DG-EC DRYING DOOR OPEN COOL DOWN TIME REMAINING PRICE INSERT COINS PUSH START FABRICS AND TEMPERATURES NORMAL HIGH TEMP PERM PRESS MED TEMP START DELICATES LOW TEMP TUMBLE NO HEAT C541i Part No. M412010R2 July 1999 WARNING • Failure to install, maintain, and/or operate this product according to the manufacturer’s instructions may result in conditions which can produce serious injury, death and/or property damage. • Do not repair or replace any part of the product or attempt any servicing unless specifically recommended or published in this Service Manual and that you understand and have the skills to carry out. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the product is properly grounded and to reduce the risk of fire, electric shock, serious injury, or death. W006R1 WARNING Repairs that are made to your products by unqualified persons can result in hazards due to improper assembly or adjustments subjecting you, or the inexperienced person making such repairs, to the risk of serious injury, electrical shock, or death. W007 CAUTION If you or an unqualified person perform service on your product, you must assume the responsibility for any personal injury or property damage which may result. The manufacturer will not be responsible for any injury or property damage arising from improper service and/or service procedures. W008 NOTE: The WARNINGS and IMPORTANT INSTRUCTIONS appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and carefulness are factors which CANNOT be built into these products. These factors MUST BE supplied by the person(s) installing, maintaining or operating the product. Always contact your dealer, distributor, service agent or the manufacturer about any problems or conditions you do not understand. Recognize Safety Symbols, Words and Labels aDANGER—Immediate hazards which WILL result in serious injury or death aWARNING—Hazards or unsafe practices which COULD result in serious injury or death. aCAUTION—Hazards or unsafe practices which COULD result in minor or moderate injury or product or property damage. W009 © Copyright 1999, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. M412010 1 TROUBLESHOOTING SectionTABLE 2 OF CONTENTS SECTION 1 Electronic Control Error Code Listing .................................................................... 5 SECTION 2 – TROUBLESHOOTING Cannot Perform Infrared (IR) Communication ....................................................... 7 Coins Ignored When Entered ................................................................................ 8 Electronic Control Has No Visible Display ............................................................. 9 Stack Tumbler No Motor Run – "Door Open" Analysis ..................................................... 10 No Motor Run – "Push Start" Analysis ..................................................... 12 No Heat Analysis ...................................................................................... 14 Safety Circuit Analysis .............................................................................. 16 Tumbler No Motor Run – "Door Open" Analysis ..................................................... 18 No Motor Run – "Push Start" Analysis ..................................................... 20 No Heat Analysis ...................................................................................... 22 Safety Circuit Analysis .............................................................................. 24 NOTE: All voltage checks in this Troubleshooting Guide are 120 Volts. There should be little variation from this voltage range. M412010 3 SECTION 1 Electronic Control Error Code Listing TROUBLESHOOTING Section 2 Listed below are some of the error codes that may appear on the Electronic Control. "E:00" General Error "E:01" Proximity Error Micro-wand IIIe is improperly aimed at Infrared communicator (angle or distance): Re-aim Micro-wand IIIe. "E:02" IR Communication Disconnection Micro-wand IIIe prematurely pulled away from Electronic Control during infrared communication: Maintain infrared connection between Micro-wand IIIe and Electronic Control during communication. "E:05" Invalid Value Communication Invalid code downloaded from Micro-wand IIIe to Electronic Control: "E:07" Inoperative Control Replace Electronic Control. "E:08" Inoperative Control Replace Electronic Control. "E:09" Proximity Error Micro-wand IIIe is improperly aimed at Infrared communicator (angle or distance): Re-aim Micro-wand IIIe. "E:0A" Proximity Error Micro-wand IIIe is improperly aimed at Infrared communicator (angle or distance): Re-aim Micro-wand IIIe. "E:0B" IR Communication Disconnection Micro-wand IIIe prematurely pulled away from Electronic Control during infrared communication: Maintain infrared connection between Micro-wand IIIe and Electronic Control during communication. "E:0C" IR Communication Disconnection Micro-wand IIIe prematurely pulled away from Electronic Control during infrared communication: Maintain infrared connection between Micro-wand IIIe and Electronic Control during communication. "E:0F" IR Communicator Programmed Off Reprogram infrared communicator on. "Err" Coin Error 1) Inoperative coin sensor: Run the Coin Drop Diagnostic test. 2) Coin drop obstruction: Check coin drop area and remove any obstructions. 3) Customer tampering: Evaluate security procedures. "OP" Open Thermistor Physical opening in the thermistor circuit: Change thermistor. "SH" Shorted Thermistor Dead short in the thermistor circuit: Change thermistor. NOTE: Disconnecting power to the unit may clear the error display. M412010 5 TROUBLESHOOTING Section 2 SECTION 2 Troubleshooting CANNOT PERFORM INFRARED COMMUNICATION ATTEMPT TO COMMUNICATE WITH THE ELECTRONIC CONTROL FROM THE MICRO-WAND. IS THERE ANY ACKNOWLEDGEMENT OF ANY KIND FROM THE ELECTRONIC CONTROL? NO NOTE: APPLICABLE MODELS ONLY. AIM MICRO-WAND CLOSER AND TRY AGAIN. IS THERE ANY CONTROL RESPONSE? NO CHECK THE FOLLOWING: – LOW BATTERY ON MICRO-WAND. – IS THE (IR) ON THE CONTROL COVERED OR BLOCKED? – IF NEEDED, REPLACE ELECTRONIC CONTROL BOARD. YES YES DOES THE ELECTRONIC CONTROL DISPLAY "E:OF" OR "– C–" ? "– C–" – IS THE (IR) CAP PROPERLY ATTACHED TO THE MICRO-WAND? COMMUNICATION SEQUENCE CHECKS OUT. "E:OF" CHECK THE FOLLOWING: – (IR) DISABLED BY MANUAL PROG. – IS THE (IR) ON THE CONTROL COVERED OR BLOCKED? – IF NEEDED, CHANGE ELECTRONIC CONTROL BOARD. M412010 T227S 7 Section 2 TROUBLESHOOTING COINS IGNORED WHEN ENTERED START COIN DROP DIAGNOSTIC TEST. ENTER SEVERAL COINS DOES THE ELECTRONIC CONTROL DISPLAY COIN COUNTER INCREMENT PROPERLY? YES MAKE SURE THE CONTROL IS RESET PROPERLY AND PROMPTING FOR A VEND. NOTE: IN THIS SECTION, BRING THE CONTROL OUT OF THE DIAGNOSTIC MODE. ALSO, MAKE SURE THE CONTROL IS NOT IN A FREE VEND MODE. NO OPEN CONTROL PANEL CHECK COIN DROP IS CONNECTION "H2" FIRMLY SEATED IN ITS RECEPTACLE ON THE CONTROL? NO RECONNECT AND RUN TEST AGAIN. YES IS THE 3-PIN CONNECTOR PLUG FIRMLY SEATED IN ITS RECEPTACLE? NO RECONNECT AND RUN TEST AGAIN. YES ARE WIRES EXITING THE COIN DROP OPTICAL SENSOR CRACKED OR BROKEN? YES REPLACE COIN DROP. NO RETEST AGAIN, IF NOT SUCCESSFUL THE FOLLOWING IS THE PROBLEM: – REPLACE COIN DROP. IF THE PROBLEM STILL EXISTS: – REPLACE ELECTRONIC CONTROL. T226S 8 M412010 TROUBLESHOOTING Section 2 ELECTRONIC CONTROL HAS NO VISIBLE DISPLAY THE ELECTRONIC CONTROL HAS NO LED OR VFD FUNCTIONING ON THE CONTROL BOARD. IS THE POWER CORD PLUGGED IN? NO PLUG ELECTRONIC CONTROL UNIT INTO ELECTRICAL OUTLET. YES OPEN CONTROL PANEL IS THERE VOLTAGE AT "H4-2" BLK TO "H4-3" WHITE? YES NO DISCONNECT POWER AND CHECK FOR BROKEN, LOOSE, OR INCORRECT WIRING FROM THE ELECTRICAL OUTLET TO THE EC CONTROL. NOTE: THIS VOLTAGE CHECK CONFIRMS THAT MAIN POWER IS PRESENT TO THE CONTROL. REPLACE ELECTRONIC CONTROL. T228S M412010 9 STACK TUMBLER Section 2 TROUBLESHOOTING NO MOTOR RUN – – "DOOR OPEN" ANALYSIS LINE VOLTAGE TO ELECTRONIC CONTROL BOARD. (#) NUMBERS NEXT TO VOLTAGE CHECKS CORRESPOND TO THE LOCATIONS MARKED ON THE WIRING SCHEMATIC. YES DISPLAY ON. IS THE COIN COUNTER COUNTING DOWN AS COINS ARE ENTERED IN THE DROP? NO YES IS THE "DOOR OPEN" FLASHING? NO YES CLOSE DOOR AND CHECK BRACKET THAT OPERATES SWITCH. STILL FLASHING NO (1) OPEN CONTROL-VOLTAGE CHECK. RED/BLACK "H4-6" TO "H4-3". CHECK MAIN POWER TO TUMBLER. RED "H4-1" TO "H4-3". REPLACE INOPERATIVE COIN DROP. THIS CHECKS VOLTAGE ON DOOR SWITCH POLES COMING INTO THE EC CONTROL BOARD. IF THE PROBLEM STILL EXISTS, REFER TO THESE OTHER TROUBLESHOOTING GUIDES: "ELECTRONIC CONTROL HAS NO VISIBLE DISPLAY" OR "COINS IGNORED WHEN ENTERED". IF VOLTAGE IS PRESENT REPLACE CONTROL. STILL FLASHING (2) NOTE: THIS TEST IS BASED ON THE ASSUMPTION THAT THE "PUSH START" BUTTON HAS BEEN PRESSED. DOES COLON FLASH AND "PUSH START" GO OFF? DOES DRYING OR COOL DOWN DISPLAY ON THE ELECTRONIC CONTROL AFTER SATISFIED VEND? REFER TO OPERATION AND PROGRAMMING MANUALS TO REVIEW THE CORRECT STATUS THE CONTROL SHOULD BE IN AFTER THE VEND PRICE HAS BEEN SATISFIED. YES (3) YES AND STILL 1) OHM TEST DOOR SWITCH. FLASHING 2) OHM TEST LINT DRAWER SWITCH. NO NO REPLACE ELECTRONIC CONTROL BOARD. AFTER CHECKING WIRING AND CONNECTIONS, REPLACE INOPERATIVE MOTOR. 10 GO TO JUMPER BLOCK AT REAR OF TUMBLER. VOLTAGE CHECK BROWN TO NEUTRAL, IS VOLTAGE THERE? AFTER CHECKING WIRING AND CONNECTIONS, REPLACE INOPERATIVE BELT GUARD SWITCH. 3) CHECK WIRING, CONNECTIONS, AND ELECTRONIC CONTROL. REPLACE INOPERATIVE COMPONENTS. NOTE: IF ANY OF THESE COMPONENTS FAIL THE OHM TEST, REPLACE THE INOPERATIVE PART. T229S M412010 STACK TUMBLER TROUBLESHOOTING Section 2 1 120V / 50-60 HZ / IPH TB1 UPPER MICROCOMPUTER CONTROL N H3-3 H4-3 TEMPERATURE REGULATING CIRCUIT CONTROLS HEAT RELAY WHT N SPARK IGNITER H4-2 YEL L M412010 ORG RED WHT BLK ORG WHT FIRST COIL BLK SECOND COIL AIR FLOW SWITCH ORG PNK BLU CAP THERM PROT * WHT BLU GAS VALVE 3 AUX MOTOR COIN DROP SENSOR GRN FS-2 RED RUN RUN GRN BLK WHT 5 YE 1 FS-1 ORG BLK COIN VAULT 2 H4-4 YEL BLK WHT BRN K2 H4-5 RED SERVICE DOOR BLK / BRN K1 RED H2-1 H2-2 H2-3 H2-5 H2-6 H2-4 GRY BLK BRN BLK / BRN BELT GUARD SWITCH BLK HEAT RELAY L1 (HOT) MOTOR RELAY AUDIT CONTROL CIRCUIT LINT DRAWER SWITCH BRN BRN V2 (VRET) RED H4-1 RED RED YEL BLK BLK / BRN I.E.I.* BOARD DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED AND START SWITCH PRESSED L2 (RET) DOOR SWITCH RED/ RED/ BRN BLK BLK H4-6 WHT BLK WHT BLK BLU H3-1 V1 (VALVE) IN USE H6-1 H6-2 G (BUR GRD) L1 TB1 THERMISTOR AVAILABLE OUTPUT TRANSISTOR IS "OFF" WHEN MACHINE IS RUNNING MAIN 2 CABINET HI-LIMIT THERMOSTAT WHT STOVE HI-LIMIT THERMOSTAT 4 MAIN 1 I.E.I. = INSTANT ELECTRONIC IGNITION 3 T230S 11 STACK TUMBLER Section 2 TROUBLESHOOTING NO MOTOR RUN – – "PUSH START" ANALYSIS "PUSH START" IS FLASHING AND "PUSH START" BUTTON HAS BEEN PRESSED. (#) NUMBERS NEXT TO VOLTAGE CHECKS CORRESPOND TO THE LOCATIONS MARKED ON THE WIRING SCHEMATIC. THERE IS NO MOTOR RUN. GO THROUGH THE FOLLOWING CHECKS: DOES COLON FLASH AND "PUSH START" GO OFF? DOES DRYING OR COOL DOWN DISPLAY ON THE ELECTONIC CONTROL AFTER SATISFIED VEND? NOTE: THIS TEST IS BASED ON THE ASSUMPTION THAT THE "PUSH START" BUTTON HAS BEEN PRESSED. NO REPLACE ELECTRONIC CONTROL BOARD. REFER TO OPERATION AND PROGRAMMING MANUALS TO REVIEW THE CORRECT STATUS THE CONTROL SHOULD BE IN AFTER THE VEND PRICE HAS BEEN SATISFIED. YES (1) (2) CHECK VOLTAGE AT RED "H4-1" TO "H4-3", IS THERE VOLTAGE? YES CHECK VOLTAGE AT YELLOW "H4-4" TO "H4-3", IS THERE VOLTAGE? NO NO (4) OPEN FRONT PANEL CHECK VOLTAGE AT BLK/BRN AT DOOR SWITCH TO GROUND, IS THERE VOLTAGE? (3) RELAY "K1" IS NOT CLOSING. REPLACE EC BOARD. YES YES GO TO JUMPER BLOCK AT REAR OF UNIT. CHECK VOLTAGE YELLOW TO NEUTRAL, IS THERE VOLTAGE? YES AFTER CHECKING WIRING AND CONNECTIONS, REPLACE INOPERATIVE MOTOR. NO REPLACE INOPERATIVE WIRING. REPLACE INOPERATIVE DOOR SWITCH. NO REPLACE INOPERATIVE WIRING. 12 T231S M412010 STACK TUMBLER TROUBLESHOOTING Section 2 4 1 120V / 50-60 HZ / IPH TB1 UPPER MICROCOMPUTER CONTROL N H3-3 H4-3 TEMPERATURE REGULATING CIRCUIT CONTROLS HEAT RELAY WHT N SPARK IGNITER H4-2 BLK COIN VAULT YEL L YEL ORG WHT BLU WHT BLK ORG GAS VALVE WHT FIRST COIL BLK SECOND COIL AIR FLOW SWITCH ORG 3 PNK BLU CAP AUX THERM PROT MOTOR COIN DROP SENSOR GRN FS-2 RED RUN RUN GRN BLK WHT 5 YE 1 FS-1 ORG BRN BLK WHT BLK / BRN H4-4 RED SERVICE DOOR K2 H4-5 RED H2-1 H2-2 H2-3 H2-5 H2-6 H2-4 GRY BLK BRN BLK / BRN BELT GUARD SWITCH BLK HEAT RELAY K1 L1 (HOT) MOTOR RELAY AUDIT CONTROL CIRCUIT LINT DRAWER SWITCH BRN BRN V2 (VRET) RED H4-1 RED RED RED BLK BLK / BRN I.E.I.* BOARD DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED AND START SWITCH PRESSED H4-6 L2 (RET) DOOR SWITCH RED/ RED/ BLK BLK YEL BRN WHT BLK WHT BLK BLU H3-1 V1 (VALVE) IN USE H6-1 H6-2 G (BUR GRD) L1 TB1 THERMISTOR AVAILABLE OUTPUT TRANSISTOR IS "OFF" WHEN MACHINE IS RUNNING WHT CABINET HI-LIMIT THERMOSTAT STOVE HI-LIMIT THERMOSTAT 4 MAIN 2 2 MAIN 1 3 * M412010 I.E.I. = INSTANT ELECTRONIC IGNITION T232S 13 STACK TUMBLER Section 2 TROUBLESHOOTING NO HEAT ANALYSIS DURING OPERATION AN "OP" OR "SH" MAY BE DISPLAYED. IF "SH" OR "OP" APPEAR, DO THE FOLLOWING CHECKS: THIS INDICATES AN OPEN OR SHORTED THERMISTOR. – CHECK WIRING AT THERMISTOR. USE DIAGNOSTIC TEST "DRYER ON TEMPERATURE TEST". – REPLACE THERMISTOR. NOTE: REFER TO OPERATION AND PROGRAMMING MANUAL TO OBTAIN DIAGNOSTIC TEST INFORMATION. (1) DOES THE CYLINDER TEMP CHECK OUT ACCORDING TO THE DIAGNOSTIC TEST? YES NOTE: THIS TEST ASSUMES MOTOR RUNS. CHECK VOLTAGE AT RED "FS–1" TO "H4-3", IS THERE VOLTAGE? NO YES (2) CHECK VOLTAGE AT ORANGE "FS–2" TO "H4-3", IS THERE VOLTAGE? NO NO CHECK WIRING FROM MOTOR TO CONTROL. IF OKAY, REPLACE INOPERATIVE MOTOR. AFTER CHECKING WIRING AND CONNECTIONS, REPLACE THERMISTOR. (3) REPLACE ELECTRONIC CONTROL BOARD. YES GO TO JUMPER BLOCK IN REAR OF TUMBLER. CHECK VOLTAGE BLUE TO NEUTRAL, IS THERE VOLTAGE? YES NO REFER TO TROUBLESHOOTING GUIDE "SAFETY CIRCUIT ANALYSIS", SEE PAGE 12. (4) IS THE SPARK IGNITER ACTIVATING? YES NO CHECK VOLTAGE AT GAS VALVE BLACK TO NEUTRAL, IS THERE VOLTAGE? YES CHECK AND REPLACE INOPERATIVE WIRING AT THE GAS VALVE. REPLACE GAS VALVE OR GAS VALVE COILS. NO (5) CHECK VOLTAGE "L1" ON I.E.I. BOARD TO GROUND, IS THERE VOLTAGE? YES NO REFER TO STACKED TUMBLER TROUBLESHOOTING GUIDE "SAFETY CIRCUIT ANALYSIS". 14 CHECK IGNITER ADJUSTMENT INSURE A GOOD IGNITER CABLE CONNECTION ON I.E.I. INSURE GOOD WIRING CONNECTION AT THE I.E.I. BOARD. REPLACE I.E.I. CONTROL BOARD. REPLACE I.E.I. CONTROL BOARD. T233S M412010 STACK TUMBLER TROUBLESHOOTING Section 2 120V / 50-60 HZ / IPH TB1 UPPER MICROCOMPUTER CONTROL N 5 H3-3 H4-3 TEMPERATURE REGULATING CIRCUIT CONTROLS HEAT RELAY WHT N SPARK IGNITER H4-2 L YE RUN M412010 ORG GAS VALVE FIRST COIL WHT BLK SECOND COIL ORG 3 PNK BLU CAP THERM PROT * BLK WHT AIR FLOW SWITCH AUX MOTOR RED COIN DROP SENSOR WHT BLU RED 5 RUN BLK WHT YEL GRN FS-2 YEL GRN BLK COIN VAULT 1 FS-1 YEL WHT BRN BLK BLK / BRN H4-4 RED SERVICE DOOR K2 H4-5 RED H2-1 H2-2 H2-3 H2-5 H2-6 H2-4 K1 GRY BLK BRN BLK / BRN BELT GUARD SWITCH BLK HEAT RELAY L1 (HOT) MOTOR RELAY AUDIT CONTROL CIRCUIT LINT DRAWER SWITCH BRN BRN V2 (VRET) RED H4-1 ORG RED ORG BLK BLK / BRN I.E.I.* BOARD DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED AND START SWITCH PRESSED L2 (RET) DOOR SWITCH RED/ RED/ BLK BLK H4-6 RED BRN WHT BLK WHT BLK BLU H3-1 V1 (VALVE) IN USE H6-1 H6-2 G (BUR GRD) L1 TB1 THERMISTOR AVAILABLE OUTPUT TRANSISTOR IS "OFF" WHEN MACHINE IS RUNNING MAIN 2 WHT CABINET HI-LIMIT THERMOSTAT STOVE HI-LIMIT THERMOSTAT 4 MAIN 1 I.E.I. = INSTANT ELECTRONIC IGNITION 1 2 4 3 T234S 15 STACK TUMBLER Section 2 TROUBLESHOOTING SAFETY CIRCUIT ANALYSIS IN CASE OF THE I.E.I. CONTROL BOARD NOT RECEIVING CONSISTENT VOLTAGE TO "L1", GO THROUGH THE FOLLOWING CHECKS. (#) NUMBERS NEXT TO VOLTAGE CHECKS CORRESPOND TO THE LOCATIONS MARKED ON THE WIRING SCHEMATIC. GO TO THE REAR OF THE TUMBLER. OPEN THE FAN HOUSING JUNCTION BOX. (1) CHECK VOLTAGE OPEN CONNECTOR ON THE PINK WIRE AND CHECK VOLTAGE FROM THE HI-LIMIT CONDUIT TO GROUND, IS THERE VOLTAGE? YES AFTER CHECKING WIRING AND CONNECTIONS, REPLACE INOPERATIVE AIR FLOW SWITCH. NO CHECKING STOVE HI-LIMIT THERMOSTAT (2) CHECK VOLTAGE AT THE ORANGE WIRE GOING TO THE HI-LIMIT CONDUIT, IS THERE VOLTAGE? YES AFTER CHECKING WIRING AND CONNECTIONS, REPLACE INOPERATIVE STOVE HI-LIMIT THERMOSTAT. NO CHECKING CABINET HI-LIMIT THERMOSTAT (3) CHECK VOLTAGE AT THE ORANGE WIRE GOING TO THE JUMPER BLOCK TO GROUND, IS THERE VOLTAGE? YES REPLACE CABINET HI-LIMIT THERMOSTAT. NO CHECK AND REPLACE INOPERATIVE WIRING BETWEEN THE EC CONTROL, JUMPER BLOCK, AND THE CABINET HI-LIMIT THERMOSTAT. 16 T235S M412010 STACK TUMBLER TROUBLESHOOTING Section 2 120V / 50-60 HZ / IPH TB1 TB1 THERMISTOR AVAILABLE OUTPUT TRANSISTOR IS "OFF" WHEN MACHINE IS RUNNING N H3-3 H4-3 TEMPERATURE REGULATING CIRCUIT CONTROLS HEAT RELAY WHT N SPARK IGNITER H4-2 L YE BLK WHT YEL RUN M412010 ORG WHT BLK ORG GAS VALVE WHT FIRST COIL BLK SECOND COIL AIR FLOW SWITCH ORG PNK BLU CAP THERM PROT * COIN DROP SENSOR WHT BLU 3 AUX MOTOR GRN GRN FS-2 RED 5 RUN FS-1 ORG BLK COIN VAULT 1 H4-4 YEL BLK WHT BRN K2 H4-5 RED SERVICE DOOR BLK / BRN K1 RED H2-1 H2-2 H2-3 H2-5 H2-6 H2-4 GRY BLK BRN BLK / BRN BELT GUARD SWITCH BLK HEAT RELAY L1 (HOT) MOTOR RELAY AUDIT CONTROL CIRCUIT LINT DRAWER SWITCH BRN BRN V2 (VRET) RED H4-1 RED RED RED BLK BLK / BRN I.E.I.* BOARD DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED AND START SWITCH PRESSED L2 (RET) DOOR SWITCH RED/ RED/ BLK BLK H4-6 YEL BRN WHT BLK WHT BLK BLU H3-1 V1 (VALVE) IN USE H6-1 H6-2 G (BUR GRD) L1 UPPER MICROCOMPUTER CONTROL MAIN 2 CABINET HI-LIMIT THERMOSTAT WHT STOVE HI-LIMIT THERMOSTAT 4 MAIN 1 I.E.I. = INSTANT ELECTRONIC IGNITION 3 2 1 T236S 17 TUMBLER Section 2 TROUBLESHOOTING NO MOTOR RUN – – "DOOR OPEN" ANALYSIS LINE VOLTAGE TO ELECTRONIC CONTROL BOARD. (#) NUMBERS NEXT TO VOLTAGE CHECKS CORRESPOND TO THE LOCATIONS MARKED ON THE WIRING SCHEMATIC. YES DISPLAY ON. IS THE COIN COUNTER COUNTING DOWN AS COINS ARE ENTERED IN THE DROP? NO YES IS THE "DOOR OPEN" FLASHING? YES CLOSE DOOR AND CHECK BRACKET THAT OPERATES SWITCH. STILL FLASHING NO NO (1) OPEN CONTROL-VOLTAGE CHECK. RED/BLACK "H4-6" TO "H4-3". CHECK MAIN POWER TO TUMBLER. CHECK AND REPLACE INOPERATIVE COIN DROP. THIS CHECKS VOLTAGE ON DOOR SWITCH POLES COMING INTO THE EC CONTROL BOARD. IF THE PROBLEM STILL EXISTS, REFER TO THESE OTHER TROUBLESHOOTING GUIDES: "ELECTRONIC CONTROL HAS NO VISIBLE DISPLAY" OR "COINS IGNORED WHEN ENTERED". DOES COLON FLASH AND "PUSH START" GO OFF? DOES DRYING OR COOL DOWN DISPLAY ON THE ELECTRONIC CONTROL AFTER SATISFIED VEND? NO REPLACE ELECTRONIC CONTROL BOARD. IF VOLTAGE IS PRESENT, REPLACE CONTROL. NOTE: THIS TEST IS BASED ON THE ASSUMPTION THAT THE "PUSH START" BUTTON HAS BEEN PRESSED. YES REFER TO OPERATION AND PROGRAMMING MANUALS TO REVIEW THE CORRECT STATUS THE CONTROL SHOULD BE IN AFTER THE VEND PRICE HAS BEEN SATISFIED. STILL FLASHING CHECK AND REPLACE INOPERATIVE WIRING AT DOOR SWITCH. STILL FLASHING REPLACE DOOR SWITCH. CHECK AND REPLACE INOPERATIVE WIRING AND CONNECTIONS. IF WIRING IS CORRECT, REPLACE MOTOR. 18 RED "H4-1" TO "H4-3". T237S M412010 TUMBLER TROUBLESHOOTING Section 2 208V/60 HZ / IPH OR 240V/60 HZ / IPH 120V / 60 HZ / IPH TB1 TB1 TB1 THERMISTOR AVAILABLE OUTPUT TRANSISTOR IS "OFF" WHEN MACHINE IS RUNNING N L2 MICROCOMPUTER CONTROL IN USE H6-1 H6-2 H3-1 WHT L1 H3-3 H4-3 TEMPERATURE REGULATING CIRCUIT CONTROLS HEAT RELAY BLK WHT N SPARK IGNITER H4-2 DOOR SWITCH HEAT RELAY K1 K2 H4-5 H4-4 FS-1 SERVICE DOOR BLK WHT GRN FS-2 ORG H2-1 H2-2 H2-3 H2-5 H2-6 H2-4 1 WHT BLU WHT BLK GAS VALVE WHT FIRST COIL BLU MOTOR RELAY V1 (VALVE) AUDIT CONTROL CIRCUIT G (BUR GRD) H4-1 V2 (VRET) BLK L1 (HOT) BLK H4-6 L2 (RET) I.E.I.* BOARD DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED AND START SWITCH PRESSED BLK BLK SECOND COIL COIN DROP SENSOR COIN VAULT L YE 1 RED 5 RUN RUN CAP AUX THERM PROT MOTOR * MAIN 2 BLK CABINET HI-LIMIT THERMOSTAT STOVE HI-LIMIT THERMOSTAT 4 MAIN 1 I.E.I. = INSTANT ELECTRONIC IGNITION M412010 AIR FLOW SWITCH 3 T238S 19 TUMBLER Section 2 TROUBLESHOOTING NO MOTOR RUN – – "PUSH START" ANALYSIS "PUSH START" IS FLASHING AND THERE IS NO MOTOR RUN ON THE TUMBLER. (#) NUMBERS NEXT TO VOLTAGE CHECKS CORRESPOND TO THE LOCATIONS MARKED ON THE WIRING SCHEMATIC. GO THROUGH THE FOLLOWING CHECKS: DOES COLON FLASH AND "PUSH START" GO OFF? DOES DRYING OR COOL DOWN DISPLAY ON THE ELECTRONIC CONTROL AFTER SATISFIED VEND? NOTE: THIS TEST IS BASED ON THE ASSUMPTION THAT THE "PUSH START" BUTTON HAS BEEN PRESSED. NO REPLACE ELECTRONIC CONTROL BOARD. REFER TO OPERATION AND PROGRAMMING MANUALS TO REVIEW THE CORRECT STATUS THE CONTROL SHOULD BE IN AFTER THE VEND PRICE HAS BEEN SATISFIED. YES (1) (2) CHECK VOLTAGE AT RED "H4–1" TO "H4-3", IS THERE VOLTAGE? YES NO (3) CHECK VOLTAGE AT YELLOW "H4–4" TO "H4-3", IS THERE VOLTAGE? NO RELAY "K1" IS NOT CLOSING. REPLACE EC BOARD. OPEN FRONT PANEL (4) CHECK VOLTAGE AT BLK WIRE AT DOOR SWITCH TO GROUND, IS THERE VOLTAGE? YES YES GO TO MOTOR AND CHECK VOLTAGE AT YELLOW TO NEUTRAL, IS THERE VOLTAGE? YES AFTER CHECKING FOR CORRECT WIRING, REPLACE INOPERATIVE MOTOR. NO REPLACE INOPERATIVE WIRING AND CONNECTIONS. REPLACE INOPERATIVE DOOR SWITCH. NO REPLACE INOPERATIVE WIRING. 20 T239S M412010 TUMBLER TROUBLESHOOTING Section 2 208V/60 HZ / IPH OR 240V/60 HZ / IPH 120V / 60 HZ / IPH TB1 TB1 TB1 THERMISTOR AVAILABLE OUTPUT TRANSISTOR IS "OFF" WHEN MACHINE IS RUNNING N L2 MICROCOMPUTER CONTROL IN USE H6-1 H6-2 H3-1 WHT L1 H3-3 H4-3 TEMPERATURE REGULATING CIRCUIT CONTROLS HEAT RELAY BLK WHT N SPARK IGNITER H4-2 DOOR SWITCH K2 H4-5 FS-1 SERVICE DOOR BLK WHT GRN FS-2 ORG H4-4 WHT BLU WHT BLK GAS VALVE WHT FIRST COIL BLU K1 H2-1 H2-2 H2-3 H2-5 1 H2-6 H2-4 4 HEAT RELAY V1 (VALVE) MOTOR RELAY AUDIT CONTROL CIRCUIT G (BUR GRD) H4-1 V2 (VRET) BLK L1 (HOT) BLK H4-6 L2 (RET) I.E.I.* BOARD DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED AND START SWITCH PRESSED BLK BLK SECOND COIL 3 COIN DROP SENSOR COIN VAULT L YE 1 RUN AIR FLOW SWITCH RED 5 RUN 3 CAP AUX THERM PROT MOTOR * MAIN 2 BLK STOVE HI-LIMIT THERMOSTAT 4 2 MAIN 1 I.E.I. = INSTANT ELECTRONIC IGNITION M412010 CABINET HI-LIMIT THERMOSTAT T240S 21 TUMBLER Section 2 TROUBLESHOOTING NO HEAT ANALYSIS DURING OPERATION AN "OP" OR "SH" MAY BE DISPLAYED. IF "SH" OR "OP" APPEAR, DO THE FOLLOWING CHECKS: THIS INDICATES AN OPEN OR SHORTED THERMISTOR. (#) NUMBERS NEXT TO VOLTAGE CHECKS CORRESPOND TO THE LOCATIONS MARKED ON THE WIRING SCHEMATIC. – CHECK WIRING AT THERMISTOR. USE DIAGNOSTIC TEST "DRYER ON TEMPERATURE TEST". – REPLACE THERMISTOR. NOTE: THIS TEST ASSUMES MOTOR RUNS. (1) DOES THE CYLINDER OR TEMPERATURE CHECK OUT ACCORDING TO THE DIAGNOSTIC TEST? YES CHECK VOLTAGE AT RED "FS-1" TO "H4-3", IS THERE VOLTAGE? NO YES NO AFTER CHECKING FOR CORRECT WIRING, REPLACE INOPERATIVE THERMISTOR. (2) CHECK VOLTAGE AT ORANGE "FS-2" TO "H4-3", IS THERE VOLTAGE? YES NO CHECK WIRING FROM MOTOR TO CONTROL. IF OKAY, REPLACE INOPERATIVE MOTOR. REPLACE ELECTRONIC CONTROL BOARD. (3) IS THE SPARK IGNITER ACTIVATING? YES NO CHECK VOLTAGE AT GAS VALVE BLACK TO NEUTRAL, IS THERE VOLTAGE? YES CHECK AND REPLACE INOPERATIVE WIRING AT THE GAS VALVE. REPLACE GAS VALVE OR GAS VALVE COILS. NO (4) CHECK VOLTAGE "L1" ON I.E.I. BOARD TO GROUND, IS THERE VOLTAGE? YES CHECK IGNITER AND CABLE TO I.E.I., IF WIRING CORRECT REPLACE I.E.I. CONTROL BOARD. CHECK WIRING AT I.E.I. CONTROL, IF WIRING CORRECT REPLACE I.E.I. CONTROL BOARD. NO REFER TO TUMBLER TROUBLESHOOTING GUIDE "SAFETY CIRCUIT ANALYSIS". 22 T241S M412010 TUMBLER TROUBLESHOOTING Section 2 208V/60 HZ / IPH OR 240V/60 HZ / IPH 120V / 60 HZ / IPH TB1 TB1 TB1 THERMISTOR AVAILABLE OUTPUT TRANSISTOR IS "OFF" WHEN MACHINE IS RUNNING N L2 MICROCOMPUTER CONTROL IN USE H6-1 H6-2 H3-1 WHT L1 4 H3-3 H4-3 TEMPERATURE REGULATING CIRCUIT CONTROLS HEAT RELAY BLK WHT N SPARK IGNITER H4-2 DOOR SWITCH HEAT RELAY K2 H4-5 H4-4 FS-1 SERVICE DOOR BLK WHT GRN FS-2 WHT BLU WHT BLK GAS VALVE WHT FIRST COIL BLU K1 V1 (VALVE) MOTOR RELAY ORG H2-1 H2-2 H2-3 H2-5 H2-6 H2-4 AUDIT CONTROL CIRCUIT G (BUR GRD) H4-1 V2 (VRET) BLK L1 (HOT) BLK H4-6 L2 (RET) I.E.I.* BOARD DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED AND START SWITCH PRESSED BLK BLK SECOND COIL COIN DROP SENSOR COIN VAULT L YE 1 RUN 3 CAP AUX THERM PROT MOTOR * MAIN 2 CABINET HI-LIMIT THERMOSTAT BLK STOVE HI-LIMIT THERMOSTAT 4 MAIN 1 I.E.I. = INSTANT ELECTRONIC IGNITION M412010 AIR FLOW SWITCH RED 5 RUN 1 2 3 T242S 23 TUMBLER Section 2 TROUBLESHOOTING SAFETY CIRCUIT ANALYSIS (#) NUMBERS NEXT TO VOLTAGE CHECKS CORRESPOND TO THE LOCATIONS MARKED ON THE WIRING SCHEMATIC. GO TO THE REAR OF THE TUMBLER. OPEN THE JUNCTION BOX. IN CASE OF THE I.E.I. CONTROL BOARD NOT RECEIVING CONSISTENT VOLTAGE TO "L1", GO THROUGH THE FOLLOWING CHECKS. (1) OPEN (3) AIR FLOW SWITCH OPERATE BOX (2) CHECK VOLTAGE OPEN CONNECTOR ON THE ORG WIRE AND CHECK VOLTAGE FROM THE HI-LIMIT CONDUIT TO GROUND, IS THERE VOLTAGE? NO REPLACE INOPERATIVE WIRING. YES CHECK VOLTAGE ON THE OTHER SIDE OF THE CABINET HI-LIMIT THERMOSTAT. IS THERE VOLTAGE? NO REPLACE CABINET HI-LIMIT THERMOSTAT YES SWITCH AND CHECK VOLTAGE BLUE WIRE COMING OUT OF THE AIR FLOW SWITCH TO NEUTRAL, IS THERE VOLTAGE? NO REPLACE INOPERATIVE AIR FLOW SWITCH. OPEN AIR FLOW SWITCH BOX YES (4) CHECK VOLTAGE OPEN CONNECTOR ON THE BLUE WIRE CHECK VOLTAGE TO NEUTRAL, IS THERE VOLTAGE? YES NO REPLACE INOPERATIVE STOVE HI-LIMIT THERMOSTAT. REPLACE INOPERATIVE WIRING BETWEEN THE STOVE HI-LIMIT AND THE ELECTRONIC CONTROL. T243S 24 M412010 TUMBLER TROUBLESHOOTING Section 2 208V/60 HZ / IPH OR 240V/60 HZ / IPH 120V / 60 HZ / IPH TB1 TB1 TB1 THERMISTOR AVAILABLE OUTPUT TRANSISTOR IS "OFF" WHEN MACHINE IS RUNNING N L2 MICROCOMPUTER CONTROL IN USE H6-1 H6-2 H3-1 WHT L1 H3-3 H4-3 TEMPERATURE REGULATING CIRCUIT CONTROLS HEAT RELAY BLK WHT N SPARK IGNITER H4-2 DOOR SWITCH HEAT RELAY K2 H4-5 H4-4 FS-1 SERVICE DOOR BLK WHT GRN FS-2 WHT BLU WHT BLK GAS VALVE FIRST COIL WHT BLU K1 V1 (VALVE) MOTOR RELAY ORG H2-1 H2-2 H2-3 H2-5 H2-6 H2-4 AUDIT CONTROL CIRCUIT G (BUR GRD) H4-1 V2 (VRET) BLK L1 (HOT) BLK H4-6 L2 (RET) I.E.I.* BOARD DOOR SENSING CIRCUIT ALLOWS CONTROL TO TURN ON MOTOR RELAY ONLY WHEN DOOR IS CLOSED AND START SWITCH PRESSED BLK BLK SECOND COIL COIN DROP SENSOR COIN VAULT L YE 1 RED 5 RUN RUN CAP AUX THERM PROT MOTOR * MAIN 2 CABINET HI-LIMIT THERMOSTAT BLK STOVE HI-LIMIT THERMOSTAT 4 MAIN 1 I.E.I. = INSTANT ELECTRONIC IGNITION M412010 AIR FLOW SWITCH 3 2 3 4 1 T244S 25