Download Rojone EziTrak Micro ETM01 User manual
Transcript
® EziTRAK A-300ET User Manual 6 PARAMETER LIST 6.1 Parameters value types • • • • • • • S8 S8[n] U8 U16 S32 U32 U64 – Signed Char – String of n Char – Unsigned Char – Unsigned Short – Signed Integer – Unsigned Integer – Unsigned Long Long Integer 6.2 System parameters 6.2.1 Deep Sleep Mode (ID=1000) Device can operate in three modes: active, GPS Sleep or deep sleep. In active mode (value 0) module is able to operate all tasks, while in GPS Sleep mode (value 1) only the GPS is turned off to conserve power but the phone module is still active, while in deep sleep mode (value 2) the GPS and phone module are turned off reducing the level of power usage. Minimum value Maximum value Recommended value 0 2 - 6.2.2 Goes with (depends on) parameters Value type U8 Analog Input value range (ID=1001) Analog input measuring resolution and range can be defined as 0…10V (value 0) or 1…30V (value 1). Minimum value Maximum value Recommended value 0 1 - 6.2.3 Goes with (depends on) parameters Value type U8 Stop Detection Source (ID=1002) Device can operate and change its working mode according to motion detection source: ignition (value 0), movement sensor (value 1), GPS (value 2). Minimum value Maximum value 0 2 6.2.4 Recommended value Goes with (depends on) parameters Value type 8.5 Data Acquisition Modes parameters U8 Static Navigation (ID=1003) When static navigation is enabled, 300ET filters out GPS jumps, when it is not moving. When it is disabled, it does not make any changes to collected GPS data. Minimum value Maximum value Recommended value 0 1 1 version 1 Goes with (depends on) parameters Value type U8 Page 32