Download Daikin RQYQ8-48PY1B Specifications
Transcript
SiBE341027 Specifications Model Name (Combination Unit) RQYQ34PY1B RQYQ36PY1B Model Name (Independent Unit) kcal / h RQYQ10PY1B+RQYQ10PY1B+RQYQ14PY1B 83,200 RQYQ10PY1B+RQYQ10PY1B+RQYQ16PY1B 87,700 Btu / h 329,000 348,000 kW 96.6 102 kW 96.0 101 kcal / h 92,700 97,200 Btu / h kW 368,000 108 386,000 113 Ivory White (5Y7.5/1) Ivory White (5Y7.5/1) mm (1680+930+765)+(1680×930×765)+(1680×1240×765) (1680×930×765)+(1680×930×765)+(1680×1240×765) Cross Fin Coil Hermetically Sealed Scroll Type Cross Fin Coil Hermetically Sealed Scroll Type ★1 Cooling Capacity (19.5°CWB) ★2 Cooling Capacity (19.0°CWB) ★3 Heating Capacity Casing Colour Dimensions: (H×W×D) Heat Exchanger Type Comp. Displacement m³/h (13.34+10.53)+(13.34+10.53)+(13.34+10.53+10.53) (13.34+10.53)+(13.34+10.53)+(13.34+10.53+10.53) Number of Revolutions r/min (6300, 2900)+(6300, 2900)+(6300, 2900, 2900) (6300, 2900)+(6300, 2900)+(6300, 2900, 2900) Motor Output×Number of Units kW ((1.4+4.5)×1)+((1.4+4.5)×1)+((1.6+4.5+4.5)×1) ((1.4+4.5)×1)+((1.4+4.5)×1)+((2.7+4.5+4.5)×1) Starting Method Soft Start Soft Start Propeller Fan Propeller Fan kW m³/min (0.75×1)+(0.75×1)+(0.35×2) 185+185+233 (0.75×1)+(0.75×1)+(0.35×2) 185+185+233 Direct Drive Direct Drive Liquid Pipe mm φ19.1 (Brazing Connection) φ19.1 (Brazing Connection) Gas Pipe mm φ34.9 (Brazing Connection) φ41.3 (Brazing Connection) kg 284+284+381 Type Fan Motor Output Airflow Rate Drive Connecting Pipes Product Mass (Machine Weight) High Pressure Switch, Fan Driver Overload Protector, Overcurrent Relay, Inverter Overload Protector Deicer Safety Devices Defrost Method Capacity Control Refrigerant Name Refrigerant Charge Control Refrigerator Oil % 5~100 R-410A 4~100 R-410A kg 11.7+11.7+11.7 Electronic Expansion Valve 11.7+11.7+11.7 Electronic Expansion Valve Refer to the nameplate of compressor Standard Accessories Installation Manual, Operation Manual, Connection Pipes, Clamps Drawing No. 284+284+381 High Pressure Switch, Fan Driver Overload Protector, Overcurrent Relay, Inverter Overload Protector Deicer Refer to the nameplate of compressor Installation Manual, Operation Manual, Connection Pipes, Clamps — Note: Specifications — ★1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level Conversion Formulae difference : 0m. ★2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level difference : 0m. ★3 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5m, level difference : 0m. kcal/h=kW×860 Btu/h=kW×3412 cfm=m³/min×35.3 25