Download Daikin RQYQ8-48PY1B Specifications

Transcript
SiBE341027
Specifications
Model Name (Combination Unit)
RQYQ34PY1B
RQYQ36PY1B
Model Name (Independent Unit)
kcal / h
RQYQ10PY1B+RQYQ10PY1B+RQYQ14PY1B
83,200
RQYQ10PY1B+RQYQ10PY1B+RQYQ16PY1B
87,700
Btu / h
329,000
348,000
kW
96.6
102
kW
96.0
101
kcal / h
92,700
97,200
Btu / h
kW
368,000
108
386,000
113
Ivory White (5Y7.5/1)
Ivory White (5Y7.5/1)
mm
(1680+930+765)+(1680×930×765)+(1680×1240×765)
(1680×930×765)+(1680×930×765)+(1680×1240×765)
Cross Fin Coil
Hermetically Sealed Scroll Type
Cross Fin Coil
Hermetically Sealed Scroll Type
★1 Cooling Capacity (19.5°CWB)
★2 Cooling Capacity (19.0°CWB)
★3 Heating Capacity
Casing Colour
Dimensions: (H×W×D)
Heat Exchanger
Type
Comp.
Displacement
m³/h
(13.34+10.53)+(13.34+10.53)+(13.34+10.53+10.53)
(13.34+10.53)+(13.34+10.53)+(13.34+10.53+10.53)
Number of Revolutions
r/min
(6300, 2900)+(6300, 2900)+(6300, 2900, 2900)
(6300, 2900)+(6300, 2900)+(6300, 2900, 2900)
Motor Output×Number
of Units
kW
((1.4+4.5)×1)+((1.4+4.5)×1)+((1.6+4.5+4.5)×1)
((1.4+4.5)×1)+((1.4+4.5)×1)+((2.7+4.5+4.5)×1)
Starting Method
Soft Start
Soft Start
Propeller Fan
Propeller Fan
kW
m³/min
(0.75×1)+(0.75×1)+(0.35×2)
185+185+233
(0.75×1)+(0.75×1)+(0.35×2)
185+185+233
Direct Drive
Direct Drive
Liquid Pipe
mm
φ19.1 (Brazing Connection)
φ19.1 (Brazing Connection)
Gas Pipe
mm
φ34.9 (Brazing Connection)
φ41.3 (Brazing Connection)
kg
284+284+381
Type
Fan
Motor Output
Airflow Rate
Drive
Connecting
Pipes
Product Mass (Machine Weight)
High Pressure Switch, Fan Driver Overload Protector,
Overcurrent Relay, Inverter Overload Protector
Deicer
Safety Devices
Defrost Method
Capacity Control
Refrigerant Name
Refrigerant
Charge
Control
Refrigerator Oil
%
5~100
R-410A
4~100
R-410A
kg
11.7+11.7+11.7
Electronic Expansion Valve
11.7+11.7+11.7
Electronic Expansion Valve
Refer to the nameplate of compressor
Standard Accessories
Installation Manual, Operation Manual, Connection Pipes,
Clamps
Drawing No.
284+284+381
High Pressure Switch, Fan Driver Overload Protector,
Overcurrent Relay, Inverter Overload Protector
Deicer
Refer to the nameplate of compressor
Installation Manual, Operation Manual, Connection Pipes,
Clamps
—
Note:
Specifications
—
★1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
Conversion Formulae
difference : 0m.
★2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
difference : 0m.
★3 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5m, level
difference : 0m.
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3
25