Overview of alarms
06/2007
Cycle alarms
61240
Channel %1 Block %2: Wrong feed type
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The feed type is not possible for this machining.
Alarm triggered by following cycles: F_DRM_DR, F_DRM_PE, F_DRM_RE, F_DRM_SI, F_GROOV,
F_MIM_TR, F_ROUGH, F_SP_EF, F_UCUT_T
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check feed type.
Program Continuation:
Clear alarm with the RESET key. Restart part program
61241
Channel %1 Block %2: Retraction plane not defined for this machining
direction
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No retraction plane has been defined for the selected machining direction.
Alarm triggered by following cycles: F_SP_RP, F_SP_RPT.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Define the missing retraction plane.
Program Continuation:
Clear alarm with the RESET key. Restart part program
61242
Channel %1 block %2: Wrong machine direction
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The machining direction has been specified incorrectly.
Alarm triggered by following cycles: F_DR, F_DR_PEC, F_DR_REA, F_DR_SIN, F_DR_TAP,
F_DRILL, F_DRILLC, F_DRILLD, F_DRM_DR, F_DRM_PE, F_DRM_RE, F_DRM_SI, F_DRM_TA,
F_MI_CON, F_MI_EDG, F_MI_TR, F_MI_TXT, F_MIM_TR, F_PI_CIR, F_PI_REC, F_PO_CIR,
F_PO_REC, F_SL_CIR, F_SL_LON, F_TAP.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check the programmed machining direction.
Program Continuation:
Clear alarm with the RESET key. Restart part program
61243
Channel %1 block %2: Correct tool change point, tool tip in
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The tool change point must be situated so far outside the retraction area that no tool protrudes into
the retraction area on turret swivelling.
Alarm triggered by following cycle: F_SP_RP
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Specify another tool change point.
Program Continuation:
Clear alarm with the RESET key. Restart part program
2-294
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition