Download Siemens SINUMERIK 802D sl Specifications
Transcript
Overview of alarms 06/2007 NCK alarms/ISO alarms Remedy: Change part program. Program Continuation: Clear alarm with NC START or RESET key and continue the program. 14088 Channel %1 block %2 axis %3 doubtful position Parameters: %1 = Channel number. %2 = Block number, label. %3 = Axis name, spindle number. Definitions: An axis position larger than 3.40e+38 increments has been programmed. Reaction: Correction block is reorganized. Interface signals are set. Alarm display. Remedy: Change part program. Program Continuation: Clear alarm with NC START or RESET key and continue the program. 14090 Channel %1 block %2 invalid D number Parameters: %1 = Channel number %2 = Block number, label Definitions: A value less than zero has been programmed under address D. A set of parameters with 25 correction values has been automatically assigned to each active tool. Each tool can have 9 sets of parameters (D1 - D9, initial setting is D1). When the D number changes, the new parameter set is active (D0 is used for deselecting the correction values). N10 G.. X... Y... T15 ; Parameter set D1 of T15 active N50 G.. X... D3 M.. ; Parameter set D3 of T15 active N60 G.. X.. T20 ; Parameter set D1 of T20 active Reaction: Correction block is reorganized. Interface signals are set. Alarm display. Remedy: Program D numbers in the permissible value range (D0, D1 to D9). Program Continuation: Clear alarm with NC START or RESET key and continue the program. 14091 Channel %1 block %2 illegal function, index %3 Parameters: %1 = Channel number %2 = Block number, label %3 = Index Definitions: A function was programmed which is not allowed in the current program context. The code of the function in question is entered in "index": Index = 1: "RET" command was programmed in the main program level Reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display. Remedy: Index = 1: Substitute "RET" command with M17/M30. Program Continuation: Clear alarm with the RESET key. Restart part program 14092 Parameters: Channel %1 block %2 axis %3 is wrong axis type %1 = Channel number %2 = Block number, label %3 = Axis name, spindle number Definitions: Reaction: Correction block is reorganized. Interface signals are set. Alarm display. Remedy: Modify part program. Program Continuation: Clear alarm with NC START or RESET key and continue the program. 2-124 " Siemens AG 2007 All Rights Reserved SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition