Breakout Box Mounting Options Breakout Boxes can be hung horizontally or vertically from any appropriate truss or structure. The Breakout Box provides threaded holes for mounting by wingbolts, along with two additional holes for attaching a clamp bracket or a variety of other hooks. The Mega-Claw truss hook is shown in these examples, however, other compatible truss hooks are available from different manufacturers. CAUTION: A safety cable should be used in all mounting configurations. Attach as shown. Wingbolt Wingbolts are provided for mounting on standard 2-inch round truss pipe. Wingbolts Safety Cable Attach safety cable at two hole locations Breakout Box Truss Pipe 15A 208V MODEL SHOWN Rack Components May Vary SIDE VIEW Figure 2-13: Wingbolt Mounting Method Clamp Bracket Rail In order to accommodate other mounting hooks, a clamp bracket rail (also used with VARI❋LITE® Series 1000™, 2000™ and 3000™ luminaires) can be attached. The bracket requires two bushings, screws, nuts and the bracket itself (refer to "Accessories" on page 12 for part numbers). Screw Bracket Procedure: 1. Install bushings. 2. Install bracket, locking into place. 3. Install truss hook. Bushing Locking Mechanism Truss Hook (not included) Bracket Press up when installing or releasing Nut Truss Hook Hardware (not provided) Figure 2-14: Installing Clamp Bracket PRG SERIES 400® POWER AND DATA DISTRIBUTION SYSTEM USER MANUAL 33