Download Centurion VECTOR2 Installation manual
Transcript
For V500 (500mm operator) 1600mm extended 1100mm retracted FIGURE 48 0° Recommended positions (Only for a 2.5 metre gate or shorter) Gate swing angle A Value Gate opening angle B Value 90° or less 205 250 100° 165 215 110° 144 180 120° 115 150 120° 60° 110° 100° 90° 80° 70° FIGURE 49 Alternative positions A and B must each be greater A+B should Up to 1.5 Up to 2 Up to 2.5 Up to 3 Up to 3.5 not exceed metres metres metres metres metres 60° - 90° or less 460mm 110mm 110mm 110mm 120mm 140mm 100° 400mm 110mm 110mm 110mm 120mm 140mm Gate swing angle 110° 340mm 120° 285mm 110mm 110mm 110mm Up to 4 metres 160mm 160mm Not recommended 110mm for A or B would ensure a 10mm clearance between the operator and gate if the gate is 50mm thick. Page 31