Download Carrier 17/19EX Specifications
Transcript
Table 8 — LID Primary and Secondary Messages and Custom Alarm/Alert Messages with Troubleshooting Guides F. Start-Up Failures: This is an alarm condition. A manual reset is required to clear. Primary Message Secondary Message Alarm Message/Primary Cause Additional Cause/Remedy Failure To Start Low Oil Pressure OILPD [VALUE] exceeded limit of [LIMIT]*. Check oil pump system. Check for closed oil supply valves. Check oil filter. Check for low oil temperature. Check transducer accuracy. Oil Press Sensor Fault OILPD [VALUE] exceeded limit of [LIMIT]*. Check oil pressure sensor. Check for excessive refrigerant in oil sump. Run oil pump manually for 5 minutes. For hermetic compressors, check both oil pressure and cooler pressure. For open-drive units, check calibration of oil pressure differential amplifier modules. Check wiring. Replace transducers if necessary. Failure To Start Low Chilled Water Flow EVFL Evap Flow Fault: Check water pump/flow switch. Check wiring to flow switch. Check through Control Test for proper switch operation. Failure To Start Low Condenser Water Flow CDFL Cond. Flow Fault: Check water pump/flow switch. Check wiring to flow switch. Check through Control Test for proper switch operation. Failure To Start Starter Fault STR FLT Starter Fault: Check starter for Fault Source. A starter protective device has faulted. Check starter for ground fault, voltage trip, temperature trip, etc. Failure To Start Starter Overload Trip STR FLT Starter Overload Trip: Check amps calibration/reset overload. Reset overloads, check ICR relay before restarting machine. Line Voltage Dropout V P Single-Cycle Dropout Detected: Check voltage supply. Check voltage supply. Check transformers for supply. Check with utility if voltage supply is erratic. Monitor must be installed to confirm consistent, single-cycle dropouts. Check low oil pressure switch. High Condenser Pressure High Condenser Pressure [LIMIT]:* Check switch 2C aux, and water temperature/flow. Check for proper design condenser flow and temperature. Check condenser approach. Check 2C auxiliary contacts on oil sump starter. Check high pressure switch. Excess Acceleration Time CA P Excess Acceleration: Check guide vane closure at start-up. Check that guide vanes are closed at start-up. Check starter for proper operation. Reduce unit pressure if possible. Failure To Start Failure To Start Failure To Start Failure To Start
Related documents
Carrier 19XL Specifications
Carrier 19EF Specifications
Carrier 17EX Specifications
Carrier 17DA Air Conditioner User Manual
Carrier 23XL Specifications
1998-2-199912-19XR XRT PICII control.p65
EX##-OMN0009DE-A
Carrier 17 Refrigerator User Manual
Carrier 19XR Specifications
Marantz SR-18EX Receiver
User Manual
- Casa Carrier