CHAPTER 5 PICK-UP/FEEDING SYSTEM
E.
Registration Roller
Assembly
1.
Removing the Registration Roller
Unit
1) Open the machine’s top unit.
2) Remove the spring [1] (front, rear).
[1]
[1]
Figure 5-232
3) Remove the two bushings [2] and remove
the registration roller lower unit [3].
[2]
[3]
[2]
Figure 5-233
5-34
COPYRIGHT © 1999 CANON INC.