3.1 RS-232C Interface Specifications 3.1.1 For CU-5000 [ 1 ] Interface Connector and Pin Assignment The CU-5000 has an RS-232C interface port (Dsub-25S). 13 1 25 14 RS-232C interface port (Dsub-25S) on the CU-5000 ■ CU-5001 Pin No. Signal 2 3 4 5 7 20 SD RD RS CS SG ER Functions Signal Input/Output CU-5001 External device Send data Receive data Request to send Ready to send Signal ground Data terminal equipment ready → ← → ← — → Pins 1 (FG), 6 (DR), and 8 (CD) are not connected. ■ CU-5002 Pin No. Signal 1 2 3 4 5 6 7 8 20 FG SD RD RS CS DR SG CD ER Functions Signal Input/Output CU-5002 External device Frame ground Send data Receive data Request to send Ready to send Data set ready Signal ground Carrier detect Data terminal equipment ready — → ← — — — — — — The input/output voltage threshold for the logical valued signal is listed below. Logical Value Input Voltage Threshold Output Voltage Threshold 0 3V min. 5V min. 1 -3V max. -5V max. 70