Technical data Only use the original fuses from ProMinent! It is not sufficient to use a fuse with the above fuse rating. 14.6 Diaphragm rupture sensor b) Reed switch (identity code specification "Stroke sensor": 2) Pin Allocation 1 (white 4.5 V ... 24 V, max. 10 mA 2 (brown) OUT, open collector, 24 V, 20 mA 3 (green) GND Data Value Unit Pulse width (low)* ≥4 ms * depending on the gear and mains frequency The polarity is unimportant. b) Namur sensor (identity code specifica‐ tion "Stroke sensor": 3) 5–25 V DC, in accordance with Namur or DIN 60947-5-6, potential-free design. Data Value Unit Nominal voltage * 8 VDC Power consumption - active surface uncovered > 3 mA Power consumption - active surface cov‐ ered < 1 mA Rated switching distance 1.5 mm * Ri ~ 1 kΩ 14.7 Cable colour Polarity blue - brown + Relay The technical data for the relay are contained in the chapter "Installation, electrical". 69