Transcript
2.0 SCOPE 2.1 Requirements A. Furnish and install a complete Intrusion Detection/Access Control system or Fire Alarm Control Panel (FACP) with the performance criteria detailed in this specification. The system shall be inclusive of all necessary functions, monitoring, and control capability as detailed herein and on accompanying Shop drawings. On-site or remote video monitoring Heating, air conditioning, and lighting management Temperature threshold detection and monitoring Humidity threshold detection and monitoring Pressure threshold detection and monitoring Power loss detection and monitoring, generator switching Leak detection and monitoring Carbon Monoxide detection and monitoring Tank level threshold detection and monitoring B. This specification document provides the requirements for the installation, programming, and configuration of a complete DMP panel. This system shall include, but not be limited to: Control panel System cabinet Power supply Digital Signaling Line Circuits (SLC) Notification Appliance Circuits (NAC) Annunciator/keypad bus Batteries Wiring Conduit Associated peripheral devices Other relevant components and accessories required to furnish and install a complete and operational addressable reporting Life Safety System. 2.2 Standards The system shall be listed as a Power Limited Device and be listed under the standards below. Each system shall be supplied with complete details on all installation criteria necessary to meet all of the listings. Burglary Listings U.S. Government Standards/Listings Meets ICD 705 Chapter 7 Intrusion Detection Systems UL 1023 Household Burglar Alarm System Units (IDS) UL 1076 Proprietary Burglar Meets DoD/NIST SCIF Standards UL 1610 Central Station Burglar Alarm Units Related Standards UL 1635 Digital Burglar Alarm Communicator System NFPA 70 National Electric Code (NEC) Units Fire Listings NFPA 72 Local Protective Signaling UL 864 Control Units for Fire Protective Signaling NFPA 72 Remote Station Protective Signaling Systems UL 985 Household Fire Warning NFPA 72 Proprietary Protective Signaling California State Fire Marshal NFPA 72 Household Fire Warning New York City FDNY COA #6167 Canadian Burglary Listings Access Control Listings ULC C1023 Household Burglar UL 294 Access Control System Units ULC/ORD-C1076 Proprietary Burglar NIST ULC S304 Central Station Burglar AES Algorithm Certificate #2350 128 Canadian Fire Listings AES Algorithm Certificate #2595 256 ULC S545 Household Fire ULC S559 Fire Signal Receiving Centres and Systems 2.3 Americans with Disabilities All indicating and notification appliances shall comply with the Americans with Disabilities Act (ADA) requirements. 2 XR150/XR350/XR550 Intrusion/Access/Fire Detection Specification