Download Apex Digital HT-170 Specifications
Transcript
APEX™ Exciter Incorporating FLO™ Technology Introduction Specifications Table 1-3 Harris APEX Exciter Performance Specifications Specification Maximum power output Power output range Regulation of output power Frequency stability Explanation 1 watt peak, 250 mW average Programable 1 to 250 mW average 1% or less 1 x 10-8 per 24 hours with no external reference 1 x 10-9 for SFN (single frequency network) with external reference Response variation < 0.2 dB, with the exciter in loopback mode Group delay < 2 nsec, with the exciter in loopback mode Phase noise 10 Hz -50 dBm 100 Hz -80 dBm 1 kHz -90 dBm 10 kHz -95 dBm 100 kHz -110 dBm 1 MHz -120 dBm Spurious output 1 In band -68 dB (-45 dB as measured in 30 kHz RBW) Adjacent channels -68 dB (-45 dB as measured in 30 kHz RBW) Signal to noise ratio 36 dB typical, with the exciter in loopback mode Note 1. Signals referenced to center of channel, at rated output, measured with 30 kHz RBW. Page: 1-6 888-2604-001 WARNING: Disconnect primary power prior to servicing. 03/08/07