Download Adaptec FS4500 - Hard Drive Array User`s guide
Transcript
Fibre Channel Storage Enclosures (FC4100) 2 Gb/sec Operation The LIO module operates in both 1 and 2 Gb/sec FC modes. The FC loop speed is selected by setting LIO switch S1.2. When the switch (located on the LIO module), is set for 2 Gb/sec, the LIO module and entire enclosure will operate at 2 Gb/sec. The LIO module does not support auto-negotiation of the FC loop speed. Daisy-chaining FC Storage Enclosures You can daisy-chain Adaptec FC Storage Enclosures to a total of 120 disk drives. Speed Mismatches between Enclosures When Storage Enclosures are daisy-chained together, all enclosures must be set to the same FC loop speed. The FC loop speed is determined by the first host-connected enclosure in the chain. If a down-stream enclosure is set incorrectly, the loop opens at that enclosure; that enclosure plus all the enclosures behind it are invisible to the host. Option Slot Loop AL_PA Assignments The option slot modules and HBAs can be hard-assigned to any of these FC loop identifiers: 0, 1, 122, 123, 124, or 125 (decimal). LIO Module LEDs Figure 6-2 shows the location of the LIO module LEDs. Table 6-4 on page 6-8 describes the function of the LEDs on the LIO module. Output LED— Indicates output cable present with valid FC signal Input LED—Indicates input cable present with valid FC signal Status LEDs 1234 Figure 6-2 LIO Module LEDs 6-7