Download Bosch D720 Installation guide

Transcript
22
en | Reporting Format Definitions
GV3 Series v8.11 or Higher
Modem IIIa2 Event
Modem IIIa2 Code
Modem IIIa2 Code Contact ID Event
Contact ID
Bosch SIA Mode
Nria/idiiiNF
Code
Force Armed Perimeter
D6500 Mode
Csiii
Partial Arm
3 456 aa uuu
Instant
Forced Close Early by
Csiii
Nria/idiiiCF
Early O/C
3 451 aa uuu
Area
Forced Close Late by Area
Forced Closing by Area
Forced Point
Invalid local access
Csiii
Csiii
Tsppp
TsF01
Nria/idiiiCF
Nria/idiiiCF
NriaXWppp
NLU
Late O/C
O/C by user
Zone/Sensor Bypass
Unsuccessful access
3 452 aa uuu
3 401 aa uuu
1 570 aa ppp
1 413 00 000
detected
Low battery on a wireless Tsppp
NriaXTppp
RF Low Battery
1 384 aa ppp
point
Low battery restore on a
Rsppp
NriaXRppp
RF Low Battery
3 384 aa ppp
wireless point
Missing Alarm
Missing Fire Supervision
Missing Supervision
Missing Trouble
Non- Fire Cancel Alarm
Normal start-up of the
Msppp
GMsppp
MTsppp
Vsppp
\siii
NsD14
NriaUZppp
NriaFZppp
NriaBZppp
NriaUYppp
Nria/idiiiBC
NRR
General Alarm
Fire Trouble
Loss of Supervision - RPM
Loss of Supervision - RPM
Cancel
System Reset
1 140 aa ppp
1 200 aa ppp
1 382 aa ppp
1 382 aa ppp
1 406 aa ppp
1 305 00 000
control panel
Opening by Area
Opening Early by Area
Opening Late by Area
Parameters changed by
Osiii
Osiii
Osiii
NsD02
Nria/idiiiOP
Nria/idiiiOK
Nria/idiiiOJ
NYG
O/C by user
Early O/C
Late O/C
Panel Programming Changed
1 401 aa uuu
1 451 aa uuu
1 452 aa uuu
1 306 00 000
RPS
Phone Line Missing (1 or TsssB
NLT1 or NLT2
Telco 1 Fault
1 351 00 000
2)
Phone Line Restored (1 or RsssB
NLR1 or NLR2
Telco 1 Fault
3 3515 00 000
2)
Point Bus Fail
TsssD
Point Bus Restoral, power RsssD
NET
NER
Protection Loop
Protection Loop
1 370 00 000
3 370 00 000
normal or bus not missing
RAM Fail with RPS
TsF02
Relay Reset by
NsD22
NRA
NpidddROrrr
Unsuccessful access
Sounder/Relay
1 413 00 000
3 320 00 000
Programmer
Relay Reset by Remote
Relay Reset by Sked
Relay Reset by User
Relay Set by Programmer
Relay Set by Remote
Relay Set by Sked
Relay Set by User
Remote Reset – System
NsD24
NsD20
NsD18
NsD21
NsD23
NsD19
NsD28
NsD11
NROrrr
NaikkkROrrr
NidiiiROrrr
NpidddRCrrr
NRCrrr
NaikkkRCrrr
NidiiiRCrrr
NRN
Sounder/Relay
Sounder/Relay
Sounder/Relay
Sounder/Relay
Sounder/Relay
Sounder/Relay
Sounder/Relay
System Reset
3 320 00 000
3 320 00 000
3 320 00 000
1 320 00 000
1 320 00 000
1 320 00 000
1 320 00 000
1 305 00 000
was reset by RPS
Restoral
Restoral from Alarm
Restoral from Ground
Rsppp
Rsppp
Rsppp
NriaBRppp
NriaBHppp
NriaBRppp
Sensor Trouble
Burglary
Ground Fault
3 380 aa ppp
3 130 aa ppp
3 310 aa ppp
Fault
ROM Checksum Fail (Not AsD12
NYX
ROM Checksum bad
1 304 00 000
Used)
Sensor Reset
Service Walk Test End
Nria/idiiiXIrrr
NidiiiTE
Sounder/Relay
Service On/Off Premises
3 320 00 000
3 466 aa uuu
F01U170805 | 02 | 2011.10
NsD27
RsssF
Quick Reference Guide
Bosch Security Systems, Inc.