Download Bosch D720 Installation guide
Transcript
22 en | Reporting Format Definitions GV3 Series v8.11 or Higher Modem IIIa2 Event Modem IIIa2 Code Modem IIIa2 Code Contact ID Event Contact ID Bosch SIA Mode Nria/idiiiNF Code Force Armed Perimeter D6500 Mode Csiii Partial Arm 3 456 aa uuu Instant Forced Close Early by Csiii Nria/idiiiCF Early O/C 3 451 aa uuu Area Forced Close Late by Area Forced Closing by Area Forced Point Invalid local access Csiii Csiii Tsppp TsF01 Nria/idiiiCF Nria/idiiiCF NriaXWppp NLU Late O/C O/C by user Zone/Sensor Bypass Unsuccessful access 3 452 aa uuu 3 401 aa uuu 1 570 aa ppp 1 413 00 000 detected Low battery on a wireless Tsppp NriaXTppp RF Low Battery 1 384 aa ppp point Low battery restore on a Rsppp NriaXRppp RF Low Battery 3 384 aa ppp wireless point Missing Alarm Missing Fire Supervision Missing Supervision Missing Trouble Non- Fire Cancel Alarm Normal start-up of the Msppp GMsppp MTsppp Vsppp \siii NsD14 NriaUZppp NriaFZppp NriaBZppp NriaUYppp Nria/idiiiBC NRR General Alarm Fire Trouble Loss of Supervision - RPM Loss of Supervision - RPM Cancel System Reset 1 140 aa ppp 1 200 aa ppp 1 382 aa ppp 1 382 aa ppp 1 406 aa ppp 1 305 00 000 control panel Opening by Area Opening Early by Area Opening Late by Area Parameters changed by Osiii Osiii Osiii NsD02 Nria/idiiiOP Nria/idiiiOK Nria/idiiiOJ NYG O/C by user Early O/C Late O/C Panel Programming Changed 1 401 aa uuu 1 451 aa uuu 1 452 aa uuu 1 306 00 000 RPS Phone Line Missing (1 or TsssB NLT1 or NLT2 Telco 1 Fault 1 351 00 000 2) Phone Line Restored (1 or RsssB NLR1 or NLR2 Telco 1 Fault 3 3515 00 000 2) Point Bus Fail TsssD Point Bus Restoral, power RsssD NET NER Protection Loop Protection Loop 1 370 00 000 3 370 00 000 normal or bus not missing RAM Fail with RPS TsF02 Relay Reset by NsD22 NRA NpidddROrrr Unsuccessful access Sounder/Relay 1 413 00 000 3 320 00 000 Programmer Relay Reset by Remote Relay Reset by Sked Relay Reset by User Relay Set by Programmer Relay Set by Remote Relay Set by Sked Relay Set by User Remote Reset – System NsD24 NsD20 NsD18 NsD21 NsD23 NsD19 NsD28 NsD11 NROrrr NaikkkROrrr NidiiiROrrr NpidddRCrrr NRCrrr NaikkkRCrrr NidiiiRCrrr NRN Sounder/Relay Sounder/Relay Sounder/Relay Sounder/Relay Sounder/Relay Sounder/Relay Sounder/Relay System Reset 3 320 00 000 3 320 00 000 3 320 00 000 1 320 00 000 1 320 00 000 1 320 00 000 1 320 00 000 1 305 00 000 was reset by RPS Restoral Restoral from Alarm Restoral from Ground Rsppp Rsppp Rsppp NriaBRppp NriaBHppp NriaBRppp Sensor Trouble Burglary Ground Fault 3 380 aa ppp 3 130 aa ppp 3 310 aa ppp Fault ROM Checksum Fail (Not AsD12 NYX ROM Checksum bad 1 304 00 000 Used) Sensor Reset Service Walk Test End Nria/idiiiXIrrr NidiiiTE Sounder/Relay Service On/Off Premises 3 320 00 000 3 466 aa uuu F01U170805 | 02 | 2011.10 NsD27 RsssF Quick Reference Guide Bosch Security Systems, Inc.