Download APRILIA RSV MILLE - PART 3 2000 Technical data

Transcript
Aprilia Consumer Service Spa
Technical Service and Training
Release 4 july 99
1.4 FAULTS TABLE
FAULT CODE
11
12
COMPONENT INVOLVED
CAMSHAFT SENSOR
CRANKSHAFT SENSOR
CAUSE
Sensor not connected, faulty
wiring, sensor broken
START ENGINE
Sensor not connected, faulty
wiring, sensor broken
START ENGINE
(t>4 sec)
(t>4 sec)
13
INTAKE PRESSURE SENSOR
Sensor not connected, faulty
wiring, sensor broken
ENGINE RUNNING OR
ENGINE STOPPED
14
INTAKE/ATMOSPHERIC PRESSURE
SENSOR
Increased differences
between sensor signals
ENGINE RUNNING OR
ENGINE STOPPED
15
THROTTLE SENSOR
Sensor not connected, faulty
wiring, sensor broken
ENGINE RUNNING OR
ENGINE STOPPED
21
COOLANT TEMPERATURE SENSOR
Sensor not connected, faulty
wiring, sensor broken
ENGINE RUNNING OR
ENGINE STOPPED
22
AIR TEMPERATURE SENSOR
Sensor not connected, faulty
wiring, sensor broken
ENGINE RUNNING OR
ENGINE STOPPED
23
ATMOSPHERIC PRESSURE SENSOR
Sensor – inside control unit ENGINE RUNNING OR
ENGINE STOPPED
– defective
33
COIL 1 CYLINDER1
Coil not connected, faulty wiring,
sensor broken
ENGINE RUNNING
34
COIL 2 CYLINDER 1
Coil not connected, faulty wiring,
sensor broken
ENGINE RUNNING
35
COIL 1 CYLINDER 2
Coil not connected, faulty wiring,
sensor broken
ENGINE RUNNING
36
COIL 2 CYLINDER 2
Coil not connected, faulty wiring,
sensor broken
ENGINE RUNNING
41
TIP OVER SENSOR
NOT CONNECTED
ENGINE RUNNING OR
ENGINE STOPPED
DEFECTIVE
NO START
CONDITIONS AT START
-
Tip over conditions
-
Safety logic not
satisfied
-
Two defective coils
on same cylinder
WHAT TO DO WHEN A FAULT CODE APPEARS:
1.
2.
3.
NOTES
CHECK COMPONENT WITH TESTER
CHECK CONTACTS (SENSOR/WIRING– WIRING/CONTROL UNIT)
CHECK WIRING
This material is didactic and
may be changed following the technical
development of the product
See table