DirecTV Receivers Serial Control
Module Application Guide
Description
This module allows you to control supported DirecTV receivers, including the D10, D11, D12,
H10, R15, R16, H20, H21, HR20, HR21 and HR21P via serial control, including limited feedback.
Note that not all receivers implement the protocol in the same manner, so some functions may
not work the same way on all models (for example, DVR controls on receivers without the DVR
feature). Also, some models may require a special cable or USB adaptor to access the serial port.
Additional information can be found in the “Hardware Configuration and Serial Pinout” section of
this document.
Supported Processors
This module is supported on any 2-series processor with RS-232 serial ports. This module
includes limited SystemBuilder compatibility; however ControlWorks does not support the use of
our modules in the SystemBuilder environment.
Compatibility
Processor Requirements
(Limited)
DirecTV Receivers v1
Telephone: (+1)440-449-1100
[email protected]
ControlWorks Consulting, LLC
http://www.controlworks.com
Hardware Configuration and Serial Pinout
RJ-22 Serial connection
If your receiver is a D10 or H10 then you should build your serial cable as indicated below. Note
that the modular connector required is a RJ-22. This is the smaller modular connector that is
used on telephone handset cords. This connector requires a special die in your crimper. A RJ11/14 crimper will not work if you attempt to crimp a RJ-22 plug with it.
USB connection
The module supports serial control via a USB port for all other receivers. This module was tested
with an IOGEAR GUC232A. DirecTV has also listed the ATEN UC-232A and the BAFO BF-810 as
being compatible with the USB port on the receiver. Please note that you must power cycle
the HR20, HR21 and HR21P after plugging in the USB dongle in order for the USB driver
to work correctly. Using the red reboot switch will not load the driver. Also note that the LED
on the dongle will not illuminate. When using a USB dongle you must pin your serial cable pin 2
to pin 3, pin 3 to pin 2 and pin 5 to pin 5. Pins 1,4,6,7,8 and 9 should not be connected in your
cable.
DirecTV Receivers v1
Telephone: (+1)440-449-1100
[email protected]
ControlWorks Consulting, LLC
http://www.controlworks.com
Module Application
The module does not support IP connectivity for receivers equipped with Ethernet. This module
allows bi-directional RS232 serial communication only. You can emulate the controls available
from the remote control as well as view the current signal strength, channel number and rapidly
tune to pre-set channels by using either an analog value or serial string. Other functions are
available such as discreet power and user lockout controls. At this time we do not have support
for discreet aspect ratios. DirecTV has reported to us that this functionality may be included in a
future release.
Channel Presets
This module provides two mechanisms for tuning to preset channels via an analog and serial
input to the module. Either the analog or serial input may be used to tune to standard channels,
while the serial input may also be used to tune to channels with a sub-channel such as off the air
high definition channels (example: 8-1),. The demonstration program includes samples of both
methods.
If using an analog value, simply initialize the analog to the desired channel number, for example
to tune to channel 202 initialize the analog to 202d. If using a serial value, send the serial string
in the format of xxxx-y where “xxxx” is the channel number, and “y” is the sub-channel number
(if no sub-channel, use 0). This string must always be exactly 6 characters, padded with zeros.
For example, to tune to channel 202 use the serial string 0202-0; to tune to channel 8-1 use the
serial string 0008-1.
DirecTV Receivers v1
Telephone: (+1)440-449-1100
[email protected]
ControlWorks Consulting, LLC
http://www.controlworks.com
Signal And Parameter Descriptions
Bracketed signals such as “[signal_name]” are optional signals
DIGITAL INPUTS
[power_on].............................................................. Pulse to turn the receiver on
[standby] ................................................................ Pulse to put the receiver into the “standby” mode
[reboot] .................................................................. Pulse to reboot the receiver, same as red reboot button
on the receiver
[get_tuner_channel] ................................................. Pulse to poll for the current channel number (Note:
The module will attempt to automatically poll for the
current channel when enter, previous channel, or
channel up or down is pressed)
[get_tuner_signal_quality] ......................................... Pulse to poll for the current signal quality reported by
the tuner
[poll_for_status]....................................................... Pulse to poll for the current transponder number,
primary type, audio type, and CAM (access card) ID.
[enable_user_controls].............................................. Pulse to enable user controls via the remote control or
front panel buttons
[disable_user_controls] ............................................. Pulse to disable user control from the remote control or
front panel buttons
[key_(x)] ................................................................ Performs the same function as the corresponding
button on the DirecTV handheld remote control
ANALOG INPUTS
[tuner_tune_to_channel] ........................................... Analog input to tune to a channel number (for example
202d = tune to channel 202). Does not support
subchannels. Note that certain receivers such as the
HR20 will not display the channel banner when direct
tuning.
SERIAL INPUTS
directv_rx$ .............................................................. Tie to RX$ line of serial port that the DirecTV receiver
is connected to
[tuner1_tune_to_channel$]........................................ Serial input to tune to a channel number. Must be 6
characters including one dash padded with 0s, for
example 0008-1 = tune to channel 8-1. Note that
certain receivers such as the HR20 will not display the
channel banner when direct tuning.
DirecTV Receivers v1
Telephone: (+1)440-449-1100
[email protected]
ControlWorks Consulting, LLC
http://www.controlworks.com
DIGITAL OUTPUTS
[tuner_no_channel_minor_fb] .................................... High when the current channel number does not
include a minor channel component. See the demo
program for an example of driving subpages based on
this feedback.
ANALOG OUTPUTS
[tuner_channel_major].............................................. Indicates the current channel number that the receiver
is tuned to
[tuner_channel_minor].............................................. Indicates the subchannel number of the channel that
the receiver is currently tuned to, if any
[tuner_signal_quality] ............................................... Full range (0-100%) value representing the quality of
the signal as reported by the tuner
[transponder_number] .............................................. The transponder number of the currently tuned
channel
SERIAL OUTPUTS
directv_tx$ .............................................................. Tie to TX$ line of serial port that the DirectTV receiver
is connected to
[primary_type]......................................................... The type of the primary (video) stream of the current
channel; one of Data, Audio, Retired, Video-SDTV,
Video-HDTV, or None.
[audio_type] ............................................................ The type of the audio stream of the current channel
[cam_id$] ............................................................... The ID of the smart card inserted in the receiver
PARAMETERS
Receiver Model ......................................................... Select the model of receiver that you are controlling
from the drop-down list
DirecTV Receivers v1
Telephone: (+1)440-449-1100
[email protected]
ControlWorks Consulting, LLC
http://www.controlworks.com
Support
This module is supported by ControlWorks Consulting, LLC. Should you need support for this
module please email [email protected] or call us at 440-729-4640. ControlWorks
normal office hours are 9 AM to 5 PM Eastern, Monday through Friday, excluding holidays.
Before calling for support, please ensure that you have loaded and tested operation using the
included demonstration program and touchpanel(s) to ensure that you understand the correct
operation of the module. It may be difficult for ControlWorks to provide support until the
demonstration program is loaded.
Updates, when available, are automatically distributed via Email notification to the address
entered when the module was purchased. In addition, updates may be obtained using your
username and password at http://www.thecontrolworks.com/customerlogin.aspx.
Distribution Package Contents
The distribution package for this module should include:
DirecTV_Receivers_V1.umc ........................................ Crestron User Module for control of DirecTV receivers
DirecTV_Receivers_Xpanel_v1.vtp............................... Demonstration XPanel
DirecTV_Receivers_v1_Demo.smw .............................. Demo program for PRO2 processor
DirecTV_cam_id_parser_v1.usp .................................. SIMPL+ File used within the module
DirecTV_cam_id_parser_v1.ush .................................. SIMPL+ Header used within the module
DirecTV_Receivers_control_v1.pdf .............................. This Help File
DirecTV Receivers v1
Telephone: (+1)440-449-1100
[email protected]
ControlWorks Consulting, LLC
http://www.controlworks.com
Revision History
V1 [email protected], [email protected] 2008.05.30
-Initial release
Development Environment
This version the module was developed on the following hardware and software. Different
versions of hardware or software may or may not operate properly. If you have questions,
please contact us.
DirecTV Receivers
HR20-700
H20-600
D10-100
Software Version
0x4062
0x4062
0x1069
Crestron Hardware
Crestron PRO2 Processor
Firmware Version
3.155.1243
Software
Crestron SIMPL Windows
Crestron Vision Tools Pro-e
Crestron Database
Crestron Symbol Library
Crestron Device Library
Software Version
2.08.38
3.7.2.8
19.06.003
531
531
DirecTV Receivers v1
Telephone: (+1)440-449-1100
[email protected]
ControlWorks Consulting, LLC
http://www.controlworks.com
ControlWorks Consulting, LLC Module License Agreement
Definitions:
ControlWorks, We, and Us refer to ControlWorks Consulting, LLC, with headquarters located at 701 Beta Drive,
Suite 22 Mayfield Village, Ohio 44143-2330. You and Dealer refer to the entity purchasing the module. Client
and End User refer to the person or entity for whom the Crestron hardware is being installed and/or will utilize
the installed system. System refers to all components described herein as well as other components, services,
or utilities required to achieve the functionality described herein. Module refers to files required to implement
the functionality provided by the module and may include source files with extensions such as UMC, USP, SMW
and VTP. Demo Program refers to a group of files used to demonstrate the capabilities of the Module, for
example a SIMPL Windows program and VisionTools Touchpanel file(s) illustrating the use of the Module but not
including the Module. Software refers to the Module and the Demo Program.
Disclaimer of Warranties
ControlWorks Consulting, LLC software is licensed to You as is. You, the consumer, bear the entire risk relating
to the quality and performance of the Software. In no event will ControlWorks Consulting, LLC be liable for
direct, indirect, incidental or consequential damages resulting from any defect in the Software, even if
ControlWorks Consulting, LLC had reason to know of the possibility of such damage. If the Software proves to
have defects, You and not Us must assume the cost of any necessary service or repair resulting from such
defects.
Provision of Support
We provide limited levels of technical support only for the most recent version of the Module as determined by
Us. We do not provide support for previous version of the module, modifications to the module not made by Us,
to persons who have not purchased the module from Us. In addition, we may decline to provide support if the
Demo Program has not been utilized. We may withdraw a module from sale and discontinue providing support
at any time and for any reason, including, for example, if the equipment for which the Module is written is
discontinued or substantially modified. The remainder of your rights and obligations pursuant to this license will
not be affected should ControlWorks discontinue support for a module.
Modification of Software
You may not decrypt (if encrypted), reverse engineer, modify, translate, disassemble, or de-compile the Module
in whole or part. You may modify the Demo Program. In no event will ControlWorks Consulting, LLC be liable for
direct, indirect, incidental or consequential damages resulting from You modifying the Software in any manner.
Indemnification/Hold Harmless
ControlWorks, in its sole and absolute discretion may refuse to provide support for the application of the Module
in such a manner that We feel has the potential for property damage, or physical injury to any person. Dealer
shall indemnify and hold harmless ControlWorks Consulting LLC, its employees, agents, and owners from any
and all liability, including direct, indirect, and consequential damages, including but not limited to personal
injury, property damage, or lost profits which may result from the operation of a program containing a
ControlWorks Consulting, LLC Module or any component thereof.
License Grant
Software authored by ControlWorks remains the property of ControlWorks. ControlWorks grants You the nonexclusive, non-transferable, perpetual license to use the Software authored by ControlWorks as a component of
Systems programmed by You. This Software is the intellectual property of ControlWorks Consulting, LLC and is
protected by law, including United States and International copyright laws.
This Software and the
accompanying license may not be transferred, resold, or assigned to other persons, organizations or other
Crestron Dealers via any means.
The use of this software indicates acceptance of the terms of this agreement.
Copyright (C) 2009 ControlWorks Consulting, LLC All Rights Reserved – Use Subject to License.
US Government Restricted Rights. Use, duplication or disclosure by the Government is subject to restrictions set
forth in subparagraphs (a)-(d) of FAR 52.227-19.
DirecTV Receivers v1
Telephone: (+1)440-449-1100
[email protected]
ControlWorks Consulting, LLC
http://www.controlworks.com