Download Curtis 3000 Specifications
Transcript
2.3 Mounting/Dimension Drawing LOGO AREA/SCALES AS REQUIRED 58.5 Information is for standard design units only. Customers should review specific diagrams for custom units. 53.6 MAX 60.0 46.0 MAX 8 5 4 1 51.5 MAX LABEL SEAL USED FOR DEVICE CONFIGURATION DO NOT CONNECT WHEN INSTALLING GAUGE MOUNTING BRACKET LABEL MEMBRANE SWITCH USED FOR FUNCTIONALITY SETUP OF GAUGE 6.3 NOTES: 1.0 Mating Connector: 8-pin Molex P/N 39-01-2085 with ULRating 94V-0, pins P/N 39-00-0039 for #18-24 AWG 2.0 52mm meters are provided in a standard round package for mounting in a 52mm DIA dash panel hole. See detail for panel cutout with key. 3.0 Material: Case- Polycarbonate; Lens- clear Polymethylmethacrylat (pmma); Cover, Overlay & Mounting Bracket- Polycarbonate. 4.0 This unit is designed for a mounting panel thickness of 0.8mm - 6.4mm. 5.0 Environmental protection: Front- IP-65; Rear- IP-40. 6.0 Weight: 0.095 kg max, including mounting bracket. LOCKING TAB LOCKING SERRATIONS LOCKING TAB MUST ALIGN WITH LOCKING SERRATIONS 2.2 Typical Wiring Diagrams Information is for standard design units only. Customers should review specific diagrams for custom units. AMP Connector SETUP HOUR METER KEYSWITCH ENABLE ENABLE SETUP HOUR METER LOAD V+ KEYSWITCH - - 1 8 7 6 5 8 7 6 5 4 3 2 1 4 3 2 1 V- 4 2 V- V- PIN 3 = 0.5A FET LOAD * SUPPLY + SUPPLY - - SUPPLY - - V- 8 7 3 8 7 3 4 6 2 5 6 2 1 3 4 5 1 2 1 VPIN 3 = 0.5A FET SETUP HOUR METER PIN 3 = 0.5A FET ENABLE ENABLE LOAD V+ + SUPPLY + SUPPLY - V- SUPPLY - 8 4 7 ENABLE V- 5 6 3 8 2 7 1 6 LOAD * 2 8 7 6 5 4 4 83 72 8 7 2 1 6 1 6 5 5 PIN 7 = 0.5A FET SETUP ENABLE * LOAD LOAD * * KEYSWITCH PIN 7 = 0.5A FET SETUP HOUR METER V+ ENABLE ENABLESETUP HOUR METER SUPPLY ++ - V+ V- 4 3 2 1 8 7 6 5 V+ 4 43 32 2 1 8 87 76 V- V- 1 5 6 5 PIN 7 = 0.5A FET + V+ HOUR METER ENABLE + * V+ - V- + SUPPLY 1 - - PIN 3 = 0.5A FET 4 3 2 8 7 6 V- SETUP ENABLE 1 5 Voltmeter *Use of output FET driver requires installation of suppression diodes across all inductive loads. KEYSWITCH LOAD 3 2 1 8 47 36 5 2 1 6 5 PIN 7 = 0.5A FET 7 PIN 7 = 0.5A FET PIN 7 = 0.5A FET PIN 3 = 0.5A FET * * LOAD 8 V- LOAD KEYSWITCH V+ 4 SUPPLY 5 LOAD KEYSWITCH SETUP ENABLE HOUR METER ENABLE SUPPLY * LOAD* KEYSWITCH KEYSWITCH PIN 7 = 0.5A FET * LOAD ENABLE ENABLE BDI (with auto-range switch) PIN 3 = 0.5A FET 3 1 SETUP HOUR METER ENABLE ENABLE PIN 7 = 0.5A FET KEYSWITCH LOAD 4V+ 3 2 1 7 6 5 4 V- - 8 * + -- KEYSWITCH SETUP HOUR METER KEYSWITCH ENABLE ENABLE LOAD V+ SETUP HOUR METER ENABLE 2 HOUR METER ENABLE SUPPLY SUPPLY PIN 3 = 0.5A FET + 3 3 LOAD KEYSWITCH 4 V- * OPEN = 24 or 48 CLOSED = 12 or 36 SUPPLY V- 4 V- SETUP ENABLE PIN 7 = 0.5A FET AUTO-RANGE SWITCH OPEN = 24 or 48 SWITCH CLOSED = AUTO-RANGE 12 or 36 OPEN = 24 or 48 AUTO-RANGECLOSED SWITCH= 12 or 36 V+ SUPPLY + + V- KEYSWITCH 5 6 V+ SUPPLY - SETUPSETUP HOURHOUR METER METER KEYSWITCH LOAD ENABLE ENABLE ENABLE KEYSWITCH V+ ENABLE 8V+ 7 V+ + * 3 FET = 0.5A FET PIN 3 =PIN 0.5A + V+ HOUR METER ENABLE Resistive based sender input (i.e. temp, fuel and pressure). SETUP ENABLE HOUR METER ENABLE LOAD + KEYSWITCH OPEN = 24 or 48 CLOSED = 12 or 36 SUPPLY SUPPLY 5 6 3 RESISTANCE BASED SENDER V+ 8V+ 7 RESISTANCE BASED SENDER + SUPPLY + * ENABLE ENABLE RESISTANCE BASED SENDER + KEYSWITCH SETUP ENABLE RESISTANCE BASED SENDER HOUR METER ENABLE SETUP ENABLE RESISTANCE BASED SENDER HOUR METER ENABLE KEYSWITCH AUTO-RANGE SWITCH OPEN = 24 or 48 SWITCH CLOSED = 12 or AUTO-RANGE 36 OPEN = 24 or 48 CLOSED = 12 or 36 AUTO-RANGE SWITCH SETUP ENABLE HOUR METER ENABLE RESISTANCE BASED SENDER Molex Connector * * LOAD *