Download Viessmann WB2B Technical data
Transcript
General Information Removing Front Enclosure Panel Some of the following start-up/service steps require the removal of the front enclosure panel. To avoid personal injury and/or product damage of any kind please follow the instructions below carefully when removing the front enclosure panel. 1. Close main gas supply valve. 2. Access the control unit by lifting and pivoting the control cover and switch off system on/off switch. 2. Fig. 2 Accessing the control to switch off the boiler 3. Turn off power supply to boiler and ensure that power supply cannot be activated during the duration of the start-up/service work. 4. Loosen the screws at the bottom of the boiler as shown (do not remove completely). 5. Slide out and remove front enclosure panel . 5. 4. 2x 5418 911 v1.6 Fig. 3 Removing front enclosure panel 9