Download Black Box SW619A Specifications
Transcript
CHAPTER 5: Operation The Multi-Head ServSwitch’s front-panel 7-segment display should now show a lowercase “u” to indicate that the Switch is ready to be upgraded: 5. Run the SSWxyz.EXE firmware-upgrade program that you downloaded in step 1. Follow the directions that appear on the host PC’s screen to transfer the new firmware to the Switch. The Switch’s 7-segment display will change to show an uppercase “U” and its dot will flash to show that the Switch’s receiving data from the PC: 6. When the upgrade’s complete, the 7-segment display will change back to the lowercase “u” and the dot will stop flashing. Move position 7 of the Switch’s DIP switch back to OFF (down) to return the Switch to normal operation. CAUTION—if the upgrade goes wrong: The upgrade program rewrites the Switch’s existing firmware code with the code in the SSWxyz.HEX file. If the upgrade process is interrupted, the Switch will contain invalid code and will not operate properly. A partial, interrupted, or failed upgrade can be fixed, but only if you immediately repeat the upgrade process without turning OFF position 7 of the Switch’s DIP switch. (The code that the Switch uses to download new firmware is not itself affected by the upgrade process.) If you move position 7 back to OFF after a failed upgrade attempt, the Switch will begin running the incomplete code. This could have unpredictable results and might damage your Switch or the attached equipment! 7. Verify that the upgrade has been successful by having the Switch indicate its new firmware revision as described in Section 4.2.8. 45