Download CME GPP-3 Specifications
Transcript
AT command set for XX Siemens mobile phones and modems +CMGS: <mr> If sending is not successful: +CMS ERROR Parameter: Length of PDU The PDU begins with the service-center address (according to GSM 04.11, [9]), followed by the TPDU (according to GSM 03.40, [6]) in hexadecimal format Message reference RP-ACK PDU according to GSM 03.40 [6] <length> <pdu> <mr> <ackpdu> AT+CMGW AT+CMGW Write an SMS to the SMS memory Test command Response: AT+CMGW=? OK/ERROR/+CME ERROR Write command If PDU mode (+CMGF=0) AT+CMGW=<length>[,<stat>]<CR> PDU is given: <ctrl-Z/ESC> Response: +CMGW: <index> +CMS ERROR Parameter: Length of PDU <length> <stat> 0 REC UNREAD i.e. received messages unread (default) 1 REC READ i.e. received messages read 2 STO UNSENT i.e. stored unsent messages 3 STO SENT i.e. stored sent messages 4 ALL i.e. all messages The PDU begins with the service-center address (according to GSM 04.11, [9]), followed by the TPDU (according to GSM 03.40, [6]) in hexadecimal format Index of message in selected memory <mem1> <pdu> <index> AT+CMMS AT+CMMS More (Short) Message to Send Test command Response: AT+CMMS=? +CMMS: (list of supported <mode>s) Parameter: Disable Keep link enabled until time between last send messages command response and next send command exceeds 5 seconds then ME closes the link and TA switches <n> to 0 2 keep link enabled until time between last send messages __________________________________________________________________________________________ <mode> 0 1 Document No.: Revision: Revision Date: 71 A30880-A10-A001-XXD376 Master R75 29. September.2004